Filters
Manufacturer
Flow Sensors
part#
description
manufacturer
FCS-GL1/2A2P-LIX-H1141/A
Flow Monitoring, Immersion Sensor with Integrated Processor, Immersion sensor, Sensor for gaseous media, Calorimetric principle, Adjustments via potentiometer, DC 3-wire, 19.2…28.8 VDC, 4…20 mA analog output, Connector device, M12 × 1
Turck
Quick Quote
FCS-GL1/2A2P-AP8X-H1141/A
Flow Monitoring, Immersion Sensor with Integrated Processor, Immersion sensor, Sensor for gaseous media, Calorimetric principle, Adjustments via potentiometer, DC 3-wire, 19.2…28.8 VDC, NO contact, PNP output, Connector device, M12 × 1
Turck
Quick Quote
FCS-G1/2A4-AP8X-H1141
Flow Monitoring, Immersion Sensor with Integrated Processor, Immersion sensor, Sensor for liquid media, Calorimetric principle, Adjustment via potentiometer, Status indicated via LED chain, DC 3-wire, 19.2…28.8 VDC, NO contact, PNP output, Connector device, M12 × 1
Turck
Quick Quote
FCS-G1/2A4-NA/D100
Flow Monitoring, Immersion Sensor without Integrated Processor, Cable length (L) 2 m, Immersion sensor, Sensor for liquid media, Calorimetric functionality, Adjustment via signal processor, Status indicated via LED chain on signal processor, Temperature range: +10…+120 °C (up to +135 °C for a short period), Cable device, 4‐wire connection to the processor
Turck
Quick Quote
FCS-N1/2A4-AN8X-H1141
Flow Monitoring, Immersion Sensor with Integrated Processor, Immersion sensor, Sensor for liquid media, Calorimetric principle, Adjustment via potentiometer, Status indicated via LED chain, DC 3-wire, 21…26 VDC, NO contact, NPN output, Connector device, M12 × 1
Turck
Quick Quote
FCS-N1/2A4-AP8X-H1141/L060
Flow Monitoring, Immersion Sensor with Integrated Processor, Immersion sensor, Sensor for liquid media, Calorimetric principle, Adjustment via potentiometer, Status indicated via LED chain, DC 3-wire, 19.2…28.8 VDC, NO contact, PNP output, Connector device, M12 × 1
Turck
Quick Quote
FCS-GL1/2A2-NA-H1141/A
Flow Monitoring, Immersion Sensor without Integrated Processor, Immersion sensor, Sensor for gaseous media, Calorimetric functionality, Adjustment via signal processor, Status indicated via LED chain on signal processor, Connector device, M12 × 1, 4‐wire connection to the processor
Turck
Quick Quote
FCS-GL1/2A4-NAEX0/A
Flow Monitoring, Immersion Sensor without Integrated Processor, Cable length (L) 2 m, Immersion sensor, Ex sensor for gaseous media, Calorimetric functionality, Adjustment via Ex signal processor, Status indicated via LED chain on signal processor, Cable device, 4-wire connection to an Ex0 processor, ATEX category II 1/2 G, Ex-zone 0, ATEX category II 1 D, Ex zone 20
Turck
Quick Quote
FCS-M18-AP8X
Flow Monitoring, Immersion Sensor with Integrated Processor, Cable length (L) 2 m, Immersion sensor, Flow sensor for gaseous media, Calorimetric principle, Adjustment via potentiometer, Status display via 2-color LED, Chrome-plated brass sensor, 3‐wire DC, 19.2…28.8 VDC, NO contact, PNP output, Cable device
Turck
Quick Quote
565379
flow sensor SFAM-62-3000L-TG12-2SA-M12 For threaded mounting. Authorisation: (* RCM Mark, * c UL us - Recognized (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certific
Festo
Quick Quote
565397
flow sensor SFAB-200U-HQ10-2SA-M12 With rotatable display and integrated QS fittings. Authorisation: (* RCM Mark, * c UL us - Recognized (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), K
Festo
Quick Quote
565396
flow sensor SFAB-200U-WQ8-2SV-M12 With rotatable display and integrated QS fittings. Authorisation: (* RCM Mark, * c UL us - Recognized (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC
Festo
Quick Quote
8036876
flow sensor SFAW-100T-TG34-E-PNLK-PNVBA-M12 For measuring and monitoring flow rate, volume and temperature of liquid media, flow measuring range 100l/min. Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to
Festo
Quick Quote
8058478
flow sensor SFAH-200U-Q8S-PNLK-PNVBA-M8 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL
Festo
Quick Quote
8058469
flow sensor SFAH-10U-Q6S-PNLK-PNVBA-L1 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL
Festo
Quick Quote
8036880
flow sensor SFAW-32T-S13-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoHS
Festo
Quick Quote
8058472
flow sensor SFAH-50U-Q8S-PNLK-PNVBA-M8 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL
Festo
Quick Quote
FCI-D15A4P-2ARX-H1160/D209
Flow Monitoring, Inline Sensor with Integrated Processor, Relay Output 24 VDC NO, Inline sensor, Compact inline flow sensor, Calorimetric principle, Monitoring of flow rate, Monitoring of the medium temperature, For water-glycol mixtures and HT110/135 Galden fluid, Parametrized via button, Protected by software code, , Operating range 3.8…38 l/min, 2 relay switching outputs, Switching outputs 24 VDC NO, Switchpoints freely adjustable
Turck
Quick Quote
FS100-300L-16-2UPN8-H1141
Flow Sensor, Immersion sensor, Screw-in adaptor with process connection NPT 1/2 male thread included in delivery, Electronics housing material/medium contact 1.4404 (316L)/1.4571 (316Ti), Immersion depth 16.9 mm, Process value display with bar graph, Flow monitoring for liquid media, Protection classes IP66, IP67 and IP69K, Adjustment of flow speed via teach function, 10…33 VDC, NO/NC contact, PNP/NPN output, IO-Link, Connector, M12 × 1, "
Turck
Quick Quote
Items per page: