8036880 Festo Flow Sensors

Festo 8036880 flow sensor SFAW-32T-S13-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoHS
Festo

Part#:8036880

Manufacturer:Festo

Alt. Part#:SFAW-32T-S13-E-PNLK-PNVBA-M12

Product Lifecycle:Active

Get a quick Quote!

About the product: flow sensor SFAW-32T-S13-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoHS

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8036880 Festo price in the box on the right side or send a quick quote.

8036880 Product Details

  • Symbol
    00995566
  • Flow measuring range start value
    1.8 l/min
  • Information on operating pressure
    Max. 12 bar at 40°C Max. 6 bar at 100 °C
  • KC characters
    KC EMC
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Method of measurement
    Flow rate: vortex Temperature: PT1000
  • Temperature measuring range end value
    90 °C
  • Temperature of medium
    0 °C ... 90 °C
  • Accuracy of temperature in ± °C
    2 °C
  • Switching function
    Window comparator Freely programmable
  • Flow characteristic curve, start value
    0 l/min
  • Overload protection
    Available
  • IO-Link®, process data width OUT
    0 Byte
  • Electrical connection
    5-pin Plug, straight
  • Materials in contact with the media
    EPDM (peroxide) PA6T/6I-reinforced
  • Flow direction
    Unidirectional P1 -> P2
  • Information on operating and pilot media
    Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured.
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, port class
    A
  • IO-Link®, service data contents IN
    32 bit volume measurement
  • DC operating voltage range
    18 V ... 30 V
  • Mounting position
    Any
  • Degree of protection
    IP65
  • Note on materials
    RoHS-compliant
  • Temperature measuring range start value
    0 °C
  • Operating medium
    Liquid media Neutral liquids
  • Accuracy of flow rate
    ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Max. output current
    100 mA
  • Temperature characteristic curve start value
    0 °C
  • Min. load resistance of voltage output
    15 kOhm
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, minimum cycle time
    5 ms
  • Fluid connector
    Barbed hose fitting 13 mm
  • Displayable unit(s)
    US gal °F
  • Type code
    SFAW
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Measured variable
    Flow rate Temperature
  • Flow measuring range end value
    32 l/min
  • Operating pressure
    0 bar ... 12 bar
  • Ambient temperature
    0 °C ... 50 °C
  • Temperature co-efficient margin in ± %FS/K
    Typ. ±0.05% FS/K
  • Analog output
    0 - 10 V 1 - 5 V
  • Temperature characteristic curve end value
    100 °C
  • Short-circuit protection
    yes
  • Protocol
    IO-Link®
  • IO-Link®, process data content IN
    1 bit BDC (temperature monitoring) 2 bit BDC (flow monitoring)
  • Reverse polarity protection
    for all electrical connections
  • Housing material
    PA-reinforced
  • Nominal temperature
    23 °C
  • Repetition accuracy of flow rate value
    < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS
  • Switching element function
    N/C contact/N/O contact switchable
  • Flow characteristic curve, end value
    32 l/min
  • Max. load resistance of current output
    500 Ohm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, process data width IN
    5 Byte
  • IO-Link®, data memory required
    500 byte
  • Max. cable length
    20 m for IO-Link® operation 30 m
  • Product weight
    300 g
  • Corrosion resistance class (CRC)
    3 - High corrosion stress

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8036880 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

8036880

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo