8058469 Festo Flow Sensors

Festo 8058469 flow sensor SFAH-10U-Q6S-PNLK-PNVBA-L1 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL
Festo

Part#:8058469

Manufacturer:Festo

Alt. Part#:SFAH-10U-Q6S-PNLK-PNVBA-L1

Product Lifecycle:Active

Get a quick Quote!

About the product: flow sensor SFAH-10U-Q6S-PNLK-PNVBA-L1 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8058469 Festo price in the box on the right side or send a quick quote.

8058469 Product Details

  • Electrical connection 1, number of pins/wires
    4
  • Idle current
    ≤ 25 mA
  • Flow direction
    Unidirectional
  • Method of measurement
    Heat transfer
  • Nominal temperature
    23 °C
  • Accuracy of flow rate
    ± (2% o.m.v. + 1% FS)
  • Flow characteristic curve, end value
    10 l/min
  • Max. load resistance of current output
    500 Ohm
  • IO-Link®, port class
    A
  • Protection against tampering
    IO-Link® PIN code
  • Electrical connection 1, connection technology
    Connection diagram L1J
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Measuring principle
    Thermal
  • Ambient temperature
    0 °C ... 50 °C
  • Zero point repetition accuracy in ± %FS
    0.2 %FS
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Switching element function
    N/C contact/N/O contact switchable
  • Short-circuit protection
    yes
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, process data width IN
    3 Byte
  • Reverse polarity protection
    for all electrical connections
  • Product weight
    60 g
  • Setting options
    IO-Link® Via display and pushbuttons
  • Protection class
    III
  • Type code
    SFAH
  • Electrical connection for input 1, connection pattern
    00995428
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Note on materials
    RoHS-compliant
  • Measured variable
    Mass flow rate Volumetric flow rate
  • Temperature of medium
    0 °C ... 50 °C
  • Temperature co-efficient margin in ± %FS/K
    typ. 0.15% FS/K
  • Max. output current
    100 mA
  • Protocol
    IO-Link®
  • IO-Link®, minimum cycle time
    4 ms
  • Pneumatic connection
    For pneumatic tubing outside diameter 6 mm
  • Degree of protection
    IP40
  • Electrical connection 1, connection type
    Plug
  • Symbol
    00995795
  • Certificate issuing authority
    UL E322346
  • Operating medium
    Argon Nitrogen
  • Pressure influence of margin in ±%FS/bar
    1 %FS/b.
  • Switching function
    Window comparator Auto difference monitoring
  • Flow characteristic curve, start value
    0 l/min
  • Overload protection
    Available
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, process data content IN
    1 bit BDC (volume monitoring) 2 bit BDC (flow monitoring)
  • DC operating voltage range
    22 V ... 26 V
  • Display type
    Illuminated LCD, multi-color
  • Displayable unit(s)
    g scft/min
  • Pneumatic connection, outlet direction
    Straight
  • KC characters
    KC EMC
  • Flow measuring range start value
    0.2 l/min
  • Operating pressure
    -0.9 bar ... 10 bar
  • Flow measuring range end value
    10 l/min
  • Repetition accuracy margin in ± %FS
    0.8 %FS
  • Analog output
    0 - 10 V 1 - 5 V
  • Min. load resistance of voltage output
    20 kOhm
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, service data contents IN
    32 bit volume/mass measurement
  • Type of mounting
    With accessories
  • Materials in contact with the media
    Wrought aluminum alloy, anodized High-alloy stainless steel
  • Pressure drop
    < 5 mbar
  • IO-Link®, data memory required
    < 500 byte
  • Mounting position
    Any
  • Housing material
    PA-reinforced
  • Corrosion resistance class (CRC)
    2 - Moderate corrosion stress

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8058469 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

8058469

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo