2904595 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904595 Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 5 V DC / 5 A
Phoenix Contact

Part#:2904595

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 147

Apr 24, 2024

About the product: Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 5 V DC / 5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904595 Phoenix Contact price in the box on the right side or send a quick quote.

2904595 Product Details

  • Height
    106 mm
  • Depth
    90 mm
  • Degree of protection
    IP20
  • Installation distance right/left (active)
    15 mm / 15 mm (POut ≥50% )
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Input fuse
    3.15 A (slow-blow, internal)
  • Nominal output current (IN)
    5 A
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Typical response time
    350 ms
  • Protection class
    II
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    14
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Flicker
    EN 61000-3-3
  • Frequency range
    50 Hz ... 60 Hz
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • Width
    22.5 mm
  • Installation distance right/left (active, passive)
    0 mm / 0 mm (POut ≤50 %)
  • Installation distance top/bottom (active)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (start-up type tested)
    -40 °C
  • Dielectric strength maximum
    300 V AC (60 s)
  • Nominal power consumption
    32.8 VA
  • Type of protection
    Transient surge protection
  • Static Boost (IStat.Boost)
    6.25 A (≤ 40 °C)
  • Protection against overvoltage at the output (OVP)
    < 8 V DC
  • Residual ripple
    < 40 mVPP (with nominal values)
  • Efficiency
    typ. 87.4 % (120 V AC)
  • Conductor cross section AWG min.
    24
  • Standard - Safety of transformers
    EN 61558-2-16
  • UL approvals
    UL Listed UL 61010-1
  • Conducted noise emission
    EN 55016
  • Contact discharge
    8 kV (Test Level 4)
  • Signal
    0.5 kV (Test Level 2 - symmetrical)
  • Voltage
    1 kV (symmetrical)
  • Voltage dips
    EN 61000-4-11
  • Voltage dip
    0 %
  • Attenuated oscillating wave
    EN 61000-4-18
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Installation distance right/left (passive)
    5 mm / 5 mm (POut ≥50% )
  • Installation distance top/bottom (passive)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Inrush current
    typ. 9.1 A (at 25 °C)
  • Mains buffering time
    typ. 52 ms (120 V AC)
  • Setting range of the output voltage (USet)
    5 V DC ... 6.2 V DC (constant capacity)
  • Dynamic Boost (IDyn.Boost)
    8 A (≤ 60 °C (5 s))
  • Control deviation
    < 0.3 % (change in load, static 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    < 0.37 W (120 V AC)
  • MTBF (IEC 61709, SN 29500)
    > 1890000 h (25 °C)
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - Safety of power supply units up to 1100 V (insulation distances)
    DIN EN 61558-2-16
  • Standard - Electrical safety
    IEC 61010-1 (SELV)
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Harmonic currents
    EN 61000-3-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Comments
    Criterion A
  • I/O/S
    asymmetrical
  • Frequency
    60 Hz
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 5.1
    27242213
  • Installation distance top/bottom (active, passive)
    30 mm / 30 mm (POut ≤50 %)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    0.37 A (100 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C or comparable)
  • Nominal output voltage
    5 V DC
  • Feedback voltage resistance
    ≤ 16 V DC (16 V e-caps in output circuit)
  • Power loss nominal load max.
    < 3.7 W (120 V AC)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    0.2 mm²
  • Standard - Safe isolation
    IEC 61558-2-16
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 1
    16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • ECLASS 10.0.1
    27040701
  • Degree of pollution
    2
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Protective circuit/component
    Varistor
  • Connection in series
    yes
  • Output power
    25 W
  • Net weight
    0.184 kg
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    10 mm
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Rail applications
    EN 50121-3-2
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    1000 A/m
  • Input
    2 kV (symmetrical)
  • Additional text
    Test Level 2
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 2)
  • ECLASS 9.0
    27040701

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$114.64

2904595

Stock:

147

Select Qty:

$114.64

$114.64 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo