Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.8 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904599 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Installation distance right/left (active) 15 mm / 15 mm (POut ≥50% )
- Installation distance top/bottom (active) 30 mm / 30 mm (POut ≥50% )
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Discharge current to PE < 0.25 mA (264 V AC, 60 Hz)
- Inrush current typ. 13 A (at 25 °C)
- Recommended breaker for input protection 6 A ... 16 A (Characteristic B, C or comparable)
- Nominal output voltage 24 V DC
- Nominal output current (IN) 3.8 A
- Type of protection Transient surge protection
- Connection in series yes
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Residual ripple < 45 mVPP (with nominal values)
- Environmental protection directive RoHS Directive 2011/65/EU
- Connection method Screw connection
- Conductor cross section AWG min. 26
- Conductor cross section AWG max. 14
- Stripping length 8 mm
- Standard - Safe isolation IEC 61558-2-16
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Frequency range 50 Hz ... 60 Hz
- Surge voltage load (surge) EN 61000-4-5
- Power frequency magnetic field EN 61000-4-8
- Additional text Test Level 2
- Test level 1 16.67 Hz 50 Hz 60 Hz (Test Level 3)
- Test level 2 16.67 Hz 50 Hz 60 Hz (Test Level 4)
- ECLASS 10.0.1 27040701
- ECLASS 7.0 27049002
- UNSPSC 21.0 39121004
- Width 45 mm
- Installation distance top/bottom (active, passive) 30 mm / 30 mm (POut ≤50 %)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Degree of pollution 2
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Current consumption 1 A (100 V AC)
- Dielectric strength maximum 300 V AC 30 s
- Mains buffering time typ. 35 ms (120 V AC)
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (constant capacity)
- Connection in parallel Yes, for redundancy and increased capacity
- Feedback voltage resistance ≤ 35 V DC
- Output power 90 W
- Net weight 0.296 kg
- Protection class II
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- SIQ CB-Scheme (IEC 61010-1, IEC 61010-2-201)
- Conducted noise emission EN 55016
- Comments Criterion B
- Input 2 kV (symmetrical)
- Voltage 300 V (1 s)
- Voltage dips EN 61000-4-11
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Attenuated oscillating wave EN 61000-4-18
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242213
- UNSPSC 13.2 39121004
- Depth 90 mm
- Installation distance top/bottom (passive) 30 mm / 30 mm (POut ≥50% )
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- ECLASS 9.0 27040701
- UNSPSC 19.0 39121004
- Height 99 mm
- Installation distance right/left (passive) 5 mm / 5 mm (POut ≥50% )
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Nominal power consumption 104 VA
- Input fuse 3.15 A (slow-blow, internal)
- Protective circuit/component Varistor
- Derating > 60 °C (2.5%/K)
- Dynamic Boost (IDyn.Boost) 7 A (≤ 60 °C (5 s))
- Maximum power dissipation in no-load condition < 1 W (120 V AC)
- Efficiency typ. 92.8 % (120 V AC)
- Assembly instructions DIN rail mounting
- Conductor cross section solid min. 0.14 mm²
- EMC requirements for noise immunity EN 61000-6-1
- EMC requirements for noise emission EN 61000-6-3
- Standard - Safety of transformers EN 61558-2-16
- UL approvals UL Listed UL 61010-1
- Electrostatic discharge EN 61000-4-2
- Test field strength 1000 A/m
- Output 1 kV (Test Level 3 - symmetrical)
- Signal 0.5 kV (Test Level 2 - symmetrical)
- Frequency 60 Hz
- Number of periods 0.5 / 1 / 5 / 50 periods
- Voltage dip 0 %
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27049000
- UNSPSC 18.0 39121004
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Typical response time 500 ms
- MTBF (IEC 61709, SN 29500) > 1272000 h (25 °C)
- Power loss nominal load max. < 7 W (120 V AC)
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible min. 0.14 mm²
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- Standard - power supply devices for low voltage with DC output EN 61204-3
- Contact discharge 8 kV (Test Level 4)
- Discharge in air 8 kV (Test Level 3)
- Fast transients (burst) EN 61000-4-4
- I/O/S asymmetrical
- Conducted interference EN 61000-4-6
- Pulse-shape magnetic field EN 61000-4-9
- Criterion A Normal operating behavior within the specified limits.
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 11.0 27040701
- ETIM 6.0 EC002540
- ETIM 7.0 EC002540
- UNSPSC 20.0 39121004
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨