Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2904599 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904599 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.8 A
Phoenix Contact

Part#:2904599

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1157

Apr 24, 2024

About the product: Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.8 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904599 Phoenix Contact price in the box on the right side or send a quick quote.

2904599 Product Details

  • Installation distance right/left (active)
    15 mm / 15 mm (POut ≥50% )
  • Installation distance top/bottom (active)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Inrush current
    typ. 13 A (at 25 °C)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C or comparable)
  • Nominal output voltage
    24 V DC
  • Nominal output current (IN)
    3.8 A
  • Type of protection
    Transient surge protection
  • Connection in series
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Residual ripple
    < 45 mVPP (with nominal values)
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Connection method
    Screw connection
  • Conductor cross section AWG min.
    26
  • Conductor cross section AWG max.
    14
  • Stripping length
    8 mm
  • Standard - Safe isolation
    IEC 61558-2-16
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Noise emission
    EN 55016
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    50 Hz ... 60 Hz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Power frequency magnetic field
    EN 61000-4-8
  • Additional text
    Test Level 2
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • ECLASS 10.0.1
    27040701
  • ECLASS 7.0
    27049002
  • UNSPSC 21.0
    39121004
  • Width
    45 mm
  • Installation distance top/bottom (active, passive)
    30 mm / 30 mm (POut ≤50 %)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Degree of pollution
    2
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    1 A (100 V AC)
  • Dielectric strength maximum
    300 V AC 30 s
  • Mains buffering time
    typ. 35 ms (120 V AC)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Feedback voltage resistance
    ≤ 35 V DC
  • Output power
    90 W
  • Net weight
    0.296 kg
  • Protection class
    II
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Conducted noise emission
    EN 55016
  • Comments
    Criterion B
  • Input
    2 kV (symmetrical)
  • Voltage
    300 V (1 s)
  • Voltage dips
    EN 61000-4-11
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Attenuated oscillating wave
    EN 61000-4-18
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27242213
  • UNSPSC 13.2
    39121004
  • Depth
    90 mm
  • Installation distance top/bottom (passive)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004
  • Height
    99 mm
  • Installation distance right/left (passive)
    5 mm / 5 mm (POut ≥50% )
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Nominal power consumption
    104 VA
  • Input fuse
    3.15 A (slow-blow, internal)
  • Protective circuit/component
    Varistor
  • Derating
    > 60 °C (2.5%/K)
  • Dynamic Boost (IDyn.Boost)
    7 A (≤ 60 °C (5 s))
  • Maximum power dissipation in no-load condition
    < 1 W (120 V AC)
  • Efficiency
    typ. 92.8 % (120 V AC)
  • Assembly instructions
    DIN rail mounting
  • Conductor cross section solid min.
    0.14 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safety of transformers
    EN 61558-2-16
  • UL approvals
    UL Listed UL 61010-1
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    1000 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Signal
    0.5 kV (Test Level 2 - symmetrical)
  • Frequency
    60 Hz
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Voltage dip
    0 %
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 6.0
    27049000
  • UNSPSC 18.0
    39121004
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Typical response time
    500 ms
  • MTBF (IEC 61709, SN 29500)
    > 1272000 h (25 °C)
  • Power loss nominal load max.
    < 7 W (120 V AC)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section flexible min.
    0.14 mm²
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Contact discharge
    8 kV (Test Level 4)
  • Discharge in air
    8 kV (Test Level 3)
  • Fast transients (burst)
    EN 61000-4-4
  • I/O/S
    asymmetrical
  • Conducted interference
    EN 61000-4-6
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Criterion A
    Normal operating behavior within the specified limits.
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 11.0
    27040701
  • ETIM 6.0
    EC002540
  • ETIM 7.0
    EC002540
  • UNSPSC 20.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$161.14

2904599

Stock:

1157

Select Qty:

$161.14

$161.14 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo