2904598 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904598 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A
Phoenix Contact

Part#:2904598

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 607

04/23/2024

About the product: Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904598 Phoenix Contact price in the box on the right side or send a quick quote.

2904598 Product Details

  • Installation distance right/left (passive)
    5 mm / 5 mm (POut ≥50% )
  • Installation distance right/left (active)
    15 mm / 15 mm (POut ≥50% )
  • Degree of protection
    IP20
  • Degree of pollution
    2
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Input fuse
    3.15 A (slow-blow, internal)
  • Nominal output voltage
    24 V DC
  • Dynamic Boost (IDyn.Boost)
    5 A (≤60 °C (5 s), Input <150 V AC Derating 0.5 %/V)
  • Derating
    > 60 °C (2.5%/K)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Conductor cross section solid min.
    0.14 mm²
  • Conductor cross section AWG min.
    26
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Noise emission
    EN 55016
  • Test field strength
    1000 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Attenuated oscillating wave
    EN 61000-4-18
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27242213
  • UNSPSC 21.0
    39121004
  • Width
    32 mm
  • Installation distance top/bottom (active, passive)
    30 mm / 30 mm (POut ≤50 %)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Dielectric strength maximum
    300 V AC 30 s
  • Current consumption
    0.85 A (100 V AC)
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Connection in series
    yes
  • Residual ripple
    < 40 mVPP (with nominal values)
  • Maximum power dissipation in no-load condition
    < 1 W (230 V AC)
  • Power loss nominal load max.
    < 5 W (230 V AC)
  • Protection class
    II
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - Safety of transformers
    EN 61558-2-16
  • Frequency
    60 Hz
  • EMC requirements for noise emission
    EN 61000-6-3
  • UL approvals
    UL Listed UL 61010-1
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Frequency range
    50 Hz ... 60 Hz
  • Comments
    Criterion B
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-11
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • ECLASS 11.0
    27040701
  • ECLASS 7.0
    27049002
  • ETIM 6.0
    EC002540
  • Height
    99 mm
  • Installation distance top/bottom (active)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Mains buffering time
    typ. 54 ms (120 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C or comparable)
  • Feedback voltage resistance
    ≤ 35 V DC
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Efficiency
    typ. 91.9 % (120 V AC)
  • MTBF (IEC 61709, SN 29500)
    > 1347000 h (25 °C)
  • Connection method
    Screw connection
  • Stripping length
    8 mm
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Standard - Safe isolation
    IEC 61558-2-16
  • Discharge in air
    8 kV (Test Level 3)
  • Contact discharge
    8 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • Additional text
    Test Level 2
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • UNSPSC 18.0
    39121004
  • UNSPSC 20.0
    39121004
  • Depth
    90 mm
  • Installation distance top/bottom (passive)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Protective circuit/component
    Varistor
  • Nominal output current (IN)
    2.5 A
  • Typical response time
    500 ms
  • Assembly instructions
    DIN rail mounting
  • Conductor cross section flexible min.
    0.14 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    2 kV (symmetrical)
  • I/O/S
    asymmetrical
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004
  • Ambient temperature (start-up type tested)
    -40 °C
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Nominal power consumption
    71 VA
  • Inrush current
    typ. 10 A (at 25 °C)
  • Static Boost (IStat.Boost)
    3.125 A (≤ 40 °C)
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Output power
    60 W
  • Net weight
    0.244 kg
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    14
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Conducted noise emission
    EN 55016
  • Electrostatic discharge
    EN 61000-4-2
  • Signal
    2 kV (Test Level 4 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage
    300 V (1 s)
  • Voltage dip
    0 %
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 6.0
    27049000
  • ETIM 7.0
    EC002540
  • UNSPSC 13.2
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$113.56

2904598

Stock:

607

Select Qty:

$113.56

$113.56 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo