2904600 Phoenix Contact AC/DC Power Supplies
Part#:2904600
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 1120
Nov 21, 2024
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904600 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- Dielectric strength maximum 300 V AC 60 s
- Mains buffering time typ. 28 ms (120 V AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristic B, C, D, K or comparable)
- Nominal output voltage 24 V DC
- Selective Fuse Breaking (ISFB) 30 A (15 ms)
- Connection in series yes
- Feedback voltage resistance ≤ 35 V DC
- MTBF (IEC 61709, SN 29500) > 1532000 h (25 °C)
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section solid max. 1 mm²
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- UL approvals UL Listed UL 508
- Depth 125 mm
- Depth with alternative assembly 39 mm
- Ambient temperature (start-up type tested) -40 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Discharge current to PE < 3.5 mA
- Power factor (cos phi) 0.82
- Nominal output current (IN) 5 A
- Height 130 mm
- Installation distance right/left 5 mm / 5 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Nominal power consumption 163 VA
- Type of protection Transient surge protection
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Output power 120 W
- Power loss nominal load max. < 17 W (120 V AC)
- Protection class I
- Conductor cross section solid min. 0.2 mm²
- EMC requirements for noise emission EN 61000-6-3
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Shipbuilding approval DNV GL, PRS, BV, LR, ABS
- SIQ BG (type approved)
- Noise emission EN 55016
- Frequency range 50 Hz ... 60 Hz
- Fast transients (burst) EN 61000-4-4
- Width with alternative assembly 122 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Input fuse 6.3 A (slow-blow, internal)
- Protective circuit/component Varistor, gas-filled surge arrester
- Dynamic Boost (IDyn.Boost) 10 A (5 s)
- Residual ripple < 30 mVPP (with nominal values)
- Typical response time 300 ms (from SLEEP MODE)
- Environmental protection directive RoHS Directive 2011/65/EU
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible max. 1.5 mm²
- EMC requirements, power plant IEC 61850-3
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Standard - power supply devices for low voltage with DC output EN 61204-3
- IECEx Ex d IIC T4...T6
- Harmonic currents EN 61000-3-2
- Additional text Test Level 2
- Test field strength 110 A/m
- Surge voltage load (surge) EN 61000-4-5
- Width 36 mm
- Height with alternative assembly 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Degree of protection IP20
- Degree of pollution 2
- Current consumption 1.7 A (100 V AC)
- Inrush current typ. 14 A (at 25 °C)
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
- Static Boost (IStat.Boost) 6.25 A
- Derating > 60 °C ... 70 °C (2.5%/K)
- Net weight 0.7 kg
- Insulation voltage input / PE 3.5 kV AC (type test)
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Safety of transformers IEC 61558-2-16 pending
- Standard - Safe isolation IEC 61558-2-16 pending
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electrostatic discharge EN 61000-4-2
- DNV GL noise radiation Class B
- Electromagnetic HF field EN 61000-4-3
- Input 2 kV (Test Level 4 - symmetrical)
- Voltage dips EN 61000-4-11
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 6.0 27049005
- UNSPSC 13.2 39121004
- Frequency 50 Hz
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Maximum power dissipation in no-load condition < 3 W (120 V AC)
- Efficiency typ. 88.8 % (120 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section AWG min. 24
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- Rail applications EN 50121-3-2
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Conducted noise emission EN 55016
- DNV GL conducted interference Class A
- Contact discharge 8 kV (Test Level 4)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Conducted interference EN 61000-4-6
- I/O/S asymmetrical
- Damped oscillating magnetic field EN 61000-4-10
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Attenuated oscillating wave EN 61000-4-18
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- ECLASS 11.0 27040701
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 7.0 27049002
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Flicker EN 61000-3-3
- Discharge in air 15 kV (Test Level 4)
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage 2.5 kV
- Voltage dip 0 %
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 5.1 27242213
- UNSPSC 20.0 39121004
- Power frequency magnetic field EN 61000-4-8
- Pulse-shape magnetic field EN 61000-4-9
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27040701
- ECLASS 9.0 27040701
- UNSPSC 19.0 39121004
- UNSPSC 18.0 39121004
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Input, output (test level 2) 10 MHz
- Criterion A Normal operating behavior within the specified limits.
- ETIM 6.0 EC002540
- UNSPSC 21.0 39121004
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$208.26
Stock:
1,120
Select Qty:
$208.26
$208.26 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨