Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2904600 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904600 Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/5 A
Phoenix Contact

Part#:2904600

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 7

04/19/2024

About the product: Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904600 Phoenix Contact price in the box on the right side or send a quick quote.

2904600 Product Details

  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Dielectric strength maximum
    300 V AC 60 s
  • Mains buffering time
    typ. 28 ms (120 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C, D, K or comparable)
  • Nominal output voltage
    24 V DC
  • Selective Fuse Breaking (ISFB)
    30 A (15 ms)
  • Connection in series
    yes
  • Feedback voltage resistance
    ≤ 35 V DC
  • MTBF (IEC 61709, SN 29500)
    > 1532000 h (25 °C)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid max.
    1 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    8 mm
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • UL approvals
    UL Listed UL 508
  • Depth
    125 mm
  • Depth with alternative assembly
    39 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Discharge current to PE
    < 3.5 mA
  • Power factor (cos phi)
    0.82
  • Nominal output current (IN)
    5 A
  • Height
    130 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • AC frequency range
    50 Hz ... 60 Hz -10 % ... +10 %
  • Nominal power consumption
    163 VA
  • Type of protection
    Transient surge protection
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Output power
    120 W
  • Power loss nominal load max.
    < 17 W (120 V AC)
  • Protection class
    I
  • Conductor cross section solid min.
    0.2 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Shipbuilding approval
    DNV GL, PRS, BV, LR, ABS
  • SIQ
    BG (type approved)
  • Noise emission
    EN 55016
  • Frequency range
    50 Hz ... 60 Hz
  • Fast transients (burst)
    EN 61000-4-4
  • Width with alternative assembly
    122 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Input fuse
    6.3 A (slow-blow, internal)
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Dynamic Boost (IDyn.Boost)
    10 A (5 s)
  • Residual ripple
    < 30 mVPP (with nominal values)
  • Typical response time
    300 ms (from SLEEP MODE)
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible max.
    1.5 mm²
  • EMC requirements, power plant
    IEC 61850-3
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • IECEx
    Ex d IIC T4...T6
  • Harmonic currents
    EN 61000-3-2
  • Additional text
    Test Level 2
  • Test field strength
    110 A/m
  • Surge voltage load (surge)
    EN 61000-4-5
  • Width
    36 mm
  • Height with alternative assembly
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Degree of protection
    IP20
  • Degree of pollution
    2
  • Current consumption
    1.7 A (100 V AC)
  • Inrush current
    typ. 14 A (at 25 °C)
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (constant capacity)
  • Static Boost (IStat.Boost)
    6.25 A
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Net weight
    0.7 kg
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    16
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Safety of transformers
    IEC 61558-2-16 pending
  • Standard - Safe isolation
    IEC 61558-2-16 pending
  • Mains variation/undervoltage
    SEMI F47-0706, EN 61000-4-11
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electrostatic discharge
    EN 61000-4-2
  • DNV GL noise radiation
    Class B
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Voltage dips
    EN 61000-4-11
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 6.0
    27049005
  • UNSPSC 13.2
    39121004
  • Frequency
    50 Hz
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    < 3 W (120 V AC)
  • Efficiency
    typ. 88.8 % (120 V AC)
  • Insulation voltage output / PE
    0.5 kV DC (type test)
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section AWG min.
    24
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Rail applications
    EN 50121-3-2
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Conducted noise emission
    EN 55016
  • DNV GL conducted interference
    Class A
  • Contact discharge
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Conducted interference
    EN 61000-4-6
  • I/O/S
    asymmetrical
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 6
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • ECLASS 11.0
    27040701
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 7.0
    27049002
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Flicker
    EN 61000-3-3
  • Discharge in air
    15 kV (Test Level 4)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Voltage
    2.5 kV
  • Voltage dip
    0 %
  • Test level 1
    15 Hz 150 Hz (Test Level 4)
  • Test level 2
    150 Hz 1.5 kHz (Test Level 4)
  • Test level 4
    15 kHz 150 kHz (Test Level 4)
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 5.1
    27242213
  • UNSPSC 20.0
    39121004
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 3
    1.5 kHz 15 kHz (Test Level 4)
  • Input, output (test level 3)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004
  • UNSPSC 18.0
    39121004
  • Number of periods
    0,5 / 1 / 5 / 50 / 250 periods
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 5
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Input, output (test level 2)
    10 MHz
  • Criterion A
    Normal operating behavior within the specified limits.
  • ETIM 6.0
    EC002540
  • UNSPSC 21.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 3 days!

1-year warranty

$193.73

2904600

Stock:

7

Select Qty:

$193.73

$193.73 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo