Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2904622 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904622 Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/20 A
Phoenix Contact

Part#:2904622

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 9

Nov 2, 2024

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/20 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904622 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width with alternative assembly
    122 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • AC frequency range
    50 Hz ... 60 Hz -10 % ... +10 %
  • Mains buffering time
    typ. 33 ms (3x 400 V AC)
  • Nominal output voltage
    24 V DC
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Connection in series
    yes
  • Typical response time
    300 ms (from SLEEP MODE)
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Protection class
    I
  • Connection method
    Push-in connection
  • Stripping length
    8 mm
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Flicker
    EN 61000-3-3
  • Frequency range
    50 Hz ... 60 Hz
  • I/O/S
    asymmetrical
  • Width
    70 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Degree of pollution
    2
  • Current consumption
    3x 0.99 A (400 V AC)
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Dynamic Boost (IDyn.Boost)
    30 A (5 s)
  • Selective Fuse Breaking (ISFB)
    120 A (15 ms)
  • Output power
    480 W
  • MTBF (IEC 61709, SN 29500)
    > 985000 h (25 °C)
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safety of transformers
    IEC 61558-2-16 pending
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Mains variation/undervoltage
    SEMI F47-0706, EN 61000-4-11
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • SIQ
    BG (type approved)
  • DNV GL noise radiation
    Class B
  • Discharge in air
    15 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-11
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 4
    15 kHz 150 kHz (Test Level 4)
  • Attenuated oscillating wave
    EN 61000-4-18
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27242200
  • ECLASS 7.0
    27049002
  • UNSPSC 21.0
    39121004
  • Height
    130 mm
  • Depth with alternative assembly
    73 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Nominal power consumption
    541 VA
  • Recommended breaker for input protection
    3x 4 A ... 20 A (Characteristic B, C or comparable)
  • Nominal output current (IN)
    20 A
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Residual ripple
    < 60 mVPP (with nominal values)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid max.
    1 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • UL approvals
    UL Listed UL 508
  • Shipbuilding approval
    DNV GL, PRS, BV, LR, ABS
  • Harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Comments
    Criterion A
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage dip
    0 %
  • Test level 1
    15 Hz 150 Hz (Test Level 4)
  • Test level 5
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Input, output (test level 2)
    10 MHz
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • ECLASS 11.0
    27040701
  • ETIM 6.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Height with alternative assembly
    130 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Degree of protection
    IP20
  • Discharge current to PE
    < 3.5 mA
  • Power factor (cos phi)
    0.94
  • Static Boost (IStat.Boost)
    25 A
  • Feedback voltage resistance
    ≤ 35 V DC
  • Maximum power dissipation in no-load condition
    < 7 W (400 V AC)
  • Efficiency
    typ. 93.9 % (400 V AC)
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • EMC requirements, power plant
    IEC 61850-3
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Conducted noise emission
    EN 55016
  • DNV GL conducted interference
    Class A
  • Test field strength
    110 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Voltage
    2.5 kV
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 6
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 6.0
    27049000
  • UNSPSC 13.2
    39121004
  • Depth
    125 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Input voltage range
    3x 400 V AC ... 500 V AC -20 % ... +10 %
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Inrush current
    typ. 2 A (at 25 °C)
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (constant capacity)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Net weight
    1.1 kg
  • Power loss nominal load max.
    < 32 W (400 V AC)
  • Insulation voltage output / PE
    0.5 kV DC (type test)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Standard - Safe isolation
    IEC 61558-2-16 pending
  • Rail applications
    EN 50121-3-2
  • Noise emission
    EN 55016
  • Contact discharge
    8 kV (Test Level 4)
  • Additional text
    Test Level 2
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Frequency
    50 Hz
  • Number of periods
    0,5 / 1 / 5 / 50 / 250 periods
  • Test level 3
    1.5 kHz 15 kHz (Test Level 4)
  • Input, output (test level 3)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 5.0
    27242200
  • ETIM 7.0
    EC002540
  • UNSPSC 18.0
    39121004
  • Power frequency magnetic field
    EN 61000-4-8
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 2
    150 Hz 1.5 kHz (Test Level 4)
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 5 days!

1-year warranty

$417.28

Stock:

9

Select Qty:

$417.28

$417.28 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo