2904617 Phoenix Contact AC/DC Power Supplies
Part#:2904617
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 5
Nov 4, 2024
Primary-switched QUINT POWER supply for DIN rail mounting, with selectable output characteristic curve and SFB Technology (selective fuse breaking), protective coating and integrated decoupling MOSFET, input: 1-phase, output: 24 V DC / 20 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904617 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Selective Fuse Breaking (ISFB) 120 A (15 ms)
- Protection against overvoltage at the output (OVP) < 30 V DC (double protection incl. shutdown)
- Dynamic Boost (IDyn.Boost) 30 A (5 s)
- Feedback voltage resistance ≤ 35 V DC
- Efficiency typ. 92.7 % (120 V AC)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard - Safe isolation IEC 61558-2-16
- Connection in series yes
- Maximum power dissipation in no-load condition < 5 W (120 V AC)
- MTBF (IEC 61709, SN 29500) > 868000 h (25 °C)
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- Nominal power consumption 520 VA
- Type of protection Transient surge protection
- Test level 7 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Height 130 mm
- Installation distance right/left 5 mm / 5 mm
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Static Boost (IStat.Boost) 25 A
- Derating > 60 °C ... 70 °C (2.5%/K)
- Output power 480 W
- Typical response time 300 ms (from SLEEP MODE)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16
- Explosive atmosphere IEC 60079-0
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Conducted noise emission EN 55016
- ECLASS 6.0 27049000
- Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable)
- Nominal output current (IN) 20 A
- Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Depth 125 mm
- Ambient temperature (operation) -40 °C ... 75 °C (> 60 °C Derating: 2.5 %/K)
- Degree of pollution 2
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Mains buffering time typ. 36 ms (120 V AC)
- Connection in parallel Yes, for redundancy and increased capacity
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Power loss nominal load max. < 38 W (120 V AC)
- Protection class I
- Conductor cross section solid max. 1 mm²
- Stripping length 8 mm
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- UL approvals UL Listed UL 508
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Residual ripple < 30 mVPP (with nominal values)
- Net weight 1.3 kg
- Insulation voltage input/output 4 kV AC (type test)
- Assembly instructions Alignable: horizontally 0 mm at Pout <50% PN, 5 mm at Pout ≥50% PN, next to active components 15 mm, vertically 50 mm
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- SIQ BG (type approved)
- Noise emission EN 55016
- Flicker EN 61000-3-3
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Voltage dips EN 61000-4-11
- Pulse-shape magnetic field EN 61000-4-9
- Electrostatic discharge EN 61000-4-2
- Contact discharge 8 kV (Test Level 4)
- Input 2 kV (Test Level 4 - symmetrical)
- Power frequency magnetic field EN 61000-4-8
- Damped oscillating magnetic field EN 61000-4-10
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Input, output (test level 2) 10 MHz
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 7.0 27049002
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- Signal 4 kV (Test Level 4 - asymmetrical)
- Voltage 2.5 kV
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Attenuated oscillating wave EN 61000-4-18
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ETIM 6.0 EC002540
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Discharge current to PE < 3.5 mA
- Input fuse 12 A (slow-blow, internal)
- Nominal input voltage range 100 V AC ... 240 V AC
- Climatic class 3K3 (in acc. with EN 60721)
- Width with alternative assembly 122 mm
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Dielectric strength maximum 300 V AC 60 s
- Current consumption 6.8 A (100 V AC)
- Shipbuilding approval DNV GL applied for
- Harmonic currents EN 61000-3-2
- Additional text Test Level 2
- DNV GL noise radiation Class B
- Fast transients (burst) EN 61000-4-4
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Test level 6 150 Hz 180 Hz (Test Level 4)
- REACh SVHC Lead 7439-92-1
- Height with alternative assembly 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Protective circuit/component Varistor, gas-filled surge arrester
- EMC requirements, power plant IEC 61850-3
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 110 A/m
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 10.0.1 27040701
- ECLASS 9.0 27040701
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Inrush current typ. 10 A (at 25 °C)
- Nominal output voltage 24 V DC
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (constant capacity)
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Degree of protection IP20
- Width 70 mm
- Depth with alternative assembly 73 mm
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Rail applications EN 50121-3-2
- DNV GL conducted interference Class A
- Frequency range 50 Hz ... 60 Hz
- Surge voltage load (surge) EN 61000-4-5
- I/O/S asymmetrical
- Frequency 50 Hz
- Voltage dip 0 %
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- ECLASS 11.0 27040701
- ETIM 7.0 EC002540
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$556.63
Stock:
5
Select Qty:
$556.63
$556.63 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨