8BVI0440HWS0.000-1 B&R Electronic Components
Part#:8BVI0440HWS0.000-1
Manufacturer:B&R
Product Lifecycle:Active
Get a quick Quote!
ACOPOSmulti inverter module, 44 A, AS, wall mounting
Check out the 8BVI0440HWS0.000-1 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight5.4 kg
- Terminal connection cross section Approbation data UL/C-UL-US 20 to 6 AWG
- Dimensions Depth Wall mounting 263 mm
- Terminal connection cross section Approbation data CSA 20 to 6 AWG
- Temperature Operation Maximum 55°C
- Dimensions Width 106.5 mm
- Terminal connection cross section Flexible and fine-stranded wires With wire end sleeves 0.5 to 16 mm²
- Temperature Operation Nominal 5 to 40°C
- Dimensions Height 317 mm
- Relative humidity Transport Max. 95% at 40°C
- Permissible mounting orientations Horizontal, face up Yes
- Installation elevation above sea level Nominal 0 to 500 m
- Temperature Transport -25 to 70°C
- Relative humidity Storage 5 to 95%
- Installation elevation above sea level Maximum 4000 m
- Permissible mounting orientations Standing horizontally No
- Temperature Storage -25 to 55°C
- Switching delay at nominal input voltage Enable 0 → 1, ready for PWM Max. 100 µs
- Relative humidity Operation 5 to 85%
- Permissible mounting orientations Hanging vertically Yes
- Electrical isolation Input - Input Yes
- Switching threshold High >15 V
- Switching delay Rising edge 52 µs ±0.5 µs (digitally filtered)
- Switching delay Falling edge 53 µs ±0.5 µs (digitally filtered)
- Input voltage Maximum 30 VDC
- Variant Shield connection Yes
- Switching delay at nominal input voltage Enable 1 → 0, PWM off Max. 20.5 ms
- Switching threshold Low <5 V
- Input voltage Nominal 24 VDC
- Electrical isolation Input - Inverter module Yes
- Max. motor line length depending on switching frequency Switching frequency 5 kHz 25 m
- Max. motor line length depending on switching frequency Switching frequency 20 kHz 25 m
- Variant U, V, W, PE Connector
- Protective measures Overload protection Yes
- Protective measures Open-circuit monitoring Yes
- Reduction of continuous current depending on installation elevation Starting at 500 m above sea level 4.4 Aeff per 1000 m
- Protective measures Short-circuit and ground fault protection Yes
- Protective measures Overload and short-circuit protection Yes
- Protective measures Undervoltage monitoring Yes
- Max. motor line length depending on switching frequency Switching frequency 10 kHz 25 m
- Reduction of continuous current depending on switching frequency Switching frequency 5 kHz 1.57 A/K (starting at 40°C)
- Output voltage DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
- Power dissipation depending on switching frequency Switching frequency 10 kHz [0.2 * IM² + 11.1 * IM + 130] W
- Power dissipation depending on switching frequency Switching frequency 20 kHz [1.85 * IM² + 3.8 * IM + 300] W
- Output voltage DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
- Power dissipation depending on switching frequency Switching frequency 5 kHz [0.07 * IM² + 7.3 * IM + 40] W
- Reduction of continuous current depending on switching frequency Switching frequency 10 kHz 0.5 A/K (starting at -10°C)
- Certifications Functional safety Yes
- Reduction of continuous current depending on switching frequency Switching frequency 20 kHz 0.36 A/K (starting at -77°C)
- Certifications KC Yes
- Voltage Nominal 750 VDC
- Degree of protection per EN 60529 IP20
- Overvoltage category per EN 61800-5-1 III
- Certifications UL cULus E225616; Power conversion equipment
- Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
- Certifications CE Yes
- Module width 2
- Certifications EAC Yes
- Modulation compared to ground potential Max. ±38 V
- Input current at nominal voltage Approx. 30 mA
- Discharge capacitance 0.22 µF
- Max. extinction energy per switching operation 3 Ws
- Response threshold for open-circuit monitoring Approx. 0.5 A
- OSSD signal connections Permitted ; Max. test pulse length: 500 µs
- Circuit Sink
- Max. switching frequency 0.5 Hz
- Response threshold for undervoltage monitoring 24 VDC +0% / -4%
- Extinction potential Approx. 30 V
- Max. internal resistance 0.15 Ω
- Max. output frequency 598 Hz
- Nominal switching frequency 5 kHz
- Terminal cable cross section dimension of shield connection 23 to 35 mm
- Output voltage 24 VDC +5.8% / -0%
- Peak current 88 Aeff
- Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
- Continuous current 4.2 A
- Possible switching frequencies 5 / 10 / 20 kHz
- Continuous current per motor connection 44 Aeff
- Input voltage 25 VDC ±1.6%
- Max. power consumption 25 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake
- Slots for plug-in modules 2
- B&R ID code 0xA075
- Variant ACOPOSmulti backplane
- Continuous power consumption 32.5 kW
- Input capacitance 32.9 µF
- DC bus capacitance 990 µF
- Continuous power per motor connection 32 kW
- Fuse protection 250 mA (slow-blow) electronic, automatic reset
- Cooling and mounting type Wall mounting
- Quantity 2
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 8BVI0440HWS0.000-1 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.