8BVI0220HCDS.000-3 B&R Electronic Components

B&R 8BVI0220HCDS.000-3 ACOPOSmulti3 SafeMOTION EnDat 2.2 inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements
B&R

Part#:8BVI0220HCDS.000-3

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

ACOPOSmulti3 SafeMOTION EnDat 2.2 inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Check out the 8BVI0220HCDS.000-3 B&R price in the box on the right side or send a quick quote.

Product Details

  • Weight4.4 kg
  • Temperature Operation Nominal
    5 to 40°C
  • Temperature Operation Maximum
    55°C
  • Dimensions Depth Cold plate
    212 mm
  • Terminal connection cross section Approbation data CSA
    28 to 10
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Pass-through mounting
    0.23 A/K (starting at 0°C)
  • Terminal connection cross section Flexible and fine-stranded wires With wire end sleeves
    0.25 to 4 mm²
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Pass-through mounting
    0.52 A/K (starting at 40°C)
  • Dimensions Width
    106.5 mm
  • Dimensions Height
    317 mm
  • Relative humidity Operation
    5 to 85%
  • Relative humidity Storage
    5 to 95%
  • Switching threshold High
    >15 V
  • Installation elevation above sea level Nominal
    0 to 500 m
  • Installation elevation above sea level Maximum
    4000 m
  • Synchronous serial interface Signal transmission
    RS485
  • Switching delay Falling edge
    53 µs ±0.5 µs (digitally filtered)
  • Input voltage Maximum
    30 VDC
  • Switching delay Rising edge
    52 µs ±0.5 µs (digitally filtered)
  • Permissible mounting orientations Hanging vertically
    Yes
  • Synchronous serial interface Data transfer rate
    6.25 Mbit/s
  • Encoder power supply Load capacity
    350 mA
  • Protective measures Open-circuit monitoring
    Yes
  • Electrical isolation Encoder - ACOPOSmulti
    No
  • Protective measures Undervoltage monitoring
    Yes
  • Max. motor line length depending on switching frequency Switching frequency 5 kHz
    25 m
  • Protective measures Overload protection
    Yes
  • Variant Shield connection
    Yes
  • Reduction of continuous current depending on installation elevation Starting at 500 m above sea level
    2.2 Aeff per 1000 m
  • Output voltage DC bus voltage (UDC): 315 to 800 VDC
    24 VDC ±6%
  • Output voltage DC bus voltage (UDC): 260 to 315 VDC
    25 VDC * (UDC/315)
  • Certifications EAC
    Yes
  • Power dissipation depending on switching frequency Switching frequency 5 kHz
    [0.65 * IM² - 0.35 * IM+ 64] W
  • Certifications KC
    In preparation
  • Module width
    2
  • Pollution degree per EN 61800-5-1
    2 (non-conductive pollution)
  • Degree of protection per EN 60529
    IP20
  • Status indicators
    UP/DN LEDs
  • Modulation compared to ground potential
    Max. ±38 V
  • Overvoltage category per EN 61800-5-1
    III
  • Discharge capacitance
    0.44 µF
  • DC bus capacitance
    1320 µF
  • Type
    EnDat 2.2
  • Max. encoder cable length
    100 m ; Depends on the cross section of the power supply wires in the encoder cable
  • Connections
    9-pin female DSUB connector
  • Slots for plug-in modules
    2
  • Response threshold for undervoltage monitoring
    24 VDC -2% / -4%
  • Input capacitance
    23.5 µF
  • Continuous power consumption
    32.37 kW
  • Max. extinction energy per switching operation
    3 Ws
  • Extinction potential
    Approx. 30 V
  • Continuous current
    2.1 A
  • Variant
    ACOPOSmulti backplane
  • Output voltage
    24 VDC +5.8% / -0.5%
  • Insulation stress of the connected motor per IEC TS 60034-25:2004
    Limit value curve A
  • Terminal cable cross section dimension of shield connection
    12 to 22 mm
  • Peak current per motor connection
    55 Aeff
  • Quantity
    2
  • Continuous power per motor connection
    16 kW
  • Continuous current per motor connection
    22 Aeff
  • Fuse protection
    250 mA (slow-blow) electronic, automatic reset
  • Dimensions Depth Pass-through mounting
    209 mm
  • Encoder power supply Protective measures Overload-proof
    Yes
  • Encoder power supply Protective measures Short-circuit proof
    Yes
  • Terminal connection cross section Approbation data UL/C-UL-US
    30 to 10
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Cold plate mounting
    0.29 A/K (starting at 10°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Cold plate mounting
    0.99 A/K (starting at 40°C)
  • Relative humidity Transport
    Max. 95% at 40°C
  • Temperature Transport
    -25 to 70°C
  • Temperature Storage
    -25 to 55°C
  • Permissible mounting orientations Standing horizontally
    No
  • Permissible mounting orientations Horizontal, face up
    Yes
  • Switching threshold Low
    <5 V
  • Electrical isolation Input - Input
    Yes
  • Input voltage Nominal
    24 VDC
  • Electrical isolation Input - Inverter module
    Yes
  • Encoder power supply Output voltage
    Typ. 12.5 V
  • Max. motor line length depending on switching frequency Switching frequency 10 kHz
    25 m
  • Protective measures Overload and short-circuit protection
    Yes
  • Variant U, V, W, PE
    Connector
  • Protective measures Short-circuit and ground fault protection
    Yes
  • Power dissipation depending on switching frequency Switching frequency 10 kHz
    [2.16 * IM² - 10.912 * IM+ 190] W
  • Voltage Nominal
    750 VDC
  • Certifications CE
    Yes
  • Certifications Functional safety
    Yes (openSAFETY)
  • Certifications UL
    cULus E225616; Power conversion equipment
  • Circuit
    Sink
  • Max. power consumption per encoder interface
    PSMC[W] = 19 V * IEncoder[A]
  • Input current at nominal voltage
    Approx. 10 mA
  • Encoder monitoring
    Yes
  • Max. switching frequency
    0.5 Hz
  • Response threshold for open-circuit monitoring
    Approx. 0.5 A
  • Max. internal resistance
    0.3 Ω
  • Max. output frequency
    598 Hz
  • Possible switching frequencies
    5/10 kHz
  • Nominal switching frequency
    5 kHz
  • B&R ID code
    0xAA1B
  • Input voltage
    25 VDC ±1.6%
  • Max. power consumption
    32 W + PSMC1 + PSMC2 + P24 V Out + PHoldingBrake(s)
  • Cooling and mounting type
    Cold plate or pass-through mounting

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo