8BVI0220HCDS.000-3 B&R Electronic Components
Part#:8BVI0220HCDS.000-3
Manufacturer:B&R
Product Lifecycle:Active
Get a quick Quote!
ACOPOSmulti3 SafeMOTION EnDat 2.2 inverter module, 22 A, AS, cold plate or pass-through mounting, 2 axes, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements
Check out the 8BVI0220HCDS.000-3 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight4.4 kg
- Temperature Operation Nominal 5 to 40°C
- Temperature Operation Maximum 55°C
- Dimensions Depth Cold plate 212 mm
- Terminal connection cross section Approbation data CSA 28 to 10
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Pass-through mounting 0.23 A/K (starting at 0°C)
- Terminal connection cross section Flexible and fine-stranded wires With wire end sleeves 0.25 to 4 mm²
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Pass-through mounting 0.52 A/K (starting at 40°C)
- Dimensions Width 106.5 mm
- Dimensions Height 317 mm
- Relative humidity Operation 5 to 85%
- Relative humidity Storage 5 to 95%
- Switching threshold High >15 V
- Installation elevation above sea level Nominal 0 to 500 m
- Installation elevation above sea level Maximum 4000 m
- Synchronous serial interface Signal transmission RS485
- Switching delay Falling edge 53 µs ±0.5 µs (digitally filtered)
- Input voltage Maximum 30 VDC
- Switching delay Rising edge 52 µs ±0.5 µs (digitally filtered)
- Permissible mounting orientations Hanging vertically Yes
- Synchronous serial interface Data transfer rate 6.25 Mbit/s
- Encoder power supply Load capacity 350 mA
- Protective measures Open-circuit monitoring Yes
- Electrical isolation Encoder - ACOPOSmulti No
- Protective measures Undervoltage monitoring Yes
- Max. motor line length depending on switching frequency Switching frequency 5 kHz 25 m
- Protective measures Overload protection Yes
- Variant Shield connection Yes
- Reduction of continuous current depending on installation elevation Starting at 500 m above sea level 2.2 Aeff per 1000 m
- Output voltage DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
- Output voltage DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
- Certifications EAC Yes
- Power dissipation depending on switching frequency Switching frequency 5 kHz [0.65 * IM² - 0.35 * IM+ 64] W
- Certifications KC In preparation
- Module width 2
- Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
- Degree of protection per EN 60529 IP20
- Status indicators UP/DN LEDs
- Modulation compared to ground potential Max. ±38 V
- Overvoltage category per EN 61800-5-1 III
- Discharge capacitance 0.44 µF
- DC bus capacitance 1320 µF
- Type EnDat 2.2
- Max. encoder cable length 100 m ; Depends on the cross section of the power supply wires in the encoder cable
- Connections 9-pin female DSUB connector
- Slots for plug-in modules 2
- Response threshold for undervoltage monitoring 24 VDC -2% / -4%
- Input capacitance 23.5 µF
- Continuous power consumption 32.37 kW
- Max. extinction energy per switching operation 3 Ws
- Extinction potential Approx. 30 V
- Continuous current 2.1 A
- Variant ACOPOSmulti backplane
- Output voltage 24 VDC +5.8% / -0.5%
- Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
- Terminal cable cross section dimension of shield connection 12 to 22 mm
- Peak current per motor connection 55 Aeff
- Quantity 2
- Continuous power per motor connection 16 kW
- Continuous current per motor connection 22 Aeff
- Fuse protection 250 mA (slow-blow) electronic, automatic reset
- Dimensions Depth Pass-through mounting 209 mm
- Encoder power supply Protective measures Overload-proof Yes
- Encoder power supply Protective measures Short-circuit proof Yes
- Terminal connection cross section Approbation data UL/C-UL-US 30 to 10
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Cold plate mounting 0.29 A/K (starting at 10°C)
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Cold plate mounting 0.99 A/K (starting at 40°C)
- Relative humidity Transport Max. 95% at 40°C
- Temperature Transport -25 to 70°C
- Temperature Storage -25 to 55°C
- Permissible mounting orientations Standing horizontally No
- Permissible mounting orientations Horizontal, face up Yes
- Switching threshold Low <5 V
- Electrical isolation Input - Input Yes
- Input voltage Nominal 24 VDC
- Electrical isolation Input - Inverter module Yes
- Encoder power supply Output voltage Typ. 12.5 V
- Max. motor line length depending on switching frequency Switching frequency 10 kHz 25 m
- Protective measures Overload and short-circuit protection Yes
- Variant U, V, W, PE Connector
- Protective measures Short-circuit and ground fault protection Yes
- Power dissipation depending on switching frequency Switching frequency 10 kHz [2.16 * IM² - 10.912 * IM+ 190] W
- Voltage Nominal 750 VDC
- Certifications CE Yes
- Certifications Functional safety Yes (openSAFETY)
- Certifications UL cULus E225616; Power conversion equipment
- Circuit Sink
- Max. power consumption per encoder interface PSMC[W] = 19 V * IEncoder[A]
- Input current at nominal voltage Approx. 10 mA
- Encoder monitoring Yes
- Max. switching frequency 0.5 Hz
- Response threshold for open-circuit monitoring Approx. 0.5 A
- Max. internal resistance 0.3 Ω
- Max. output frequency 598 Hz
- Possible switching frequencies 5/10 kHz
- Nominal switching frequency 5 kHz
- B&R ID code 0xAA1B
- Input voltage 25 VDC ±1.6%
- Max. power consumption 32 W + PSMC1 + PSMC2 + P24 V Out + PHoldingBrake(s)
- Cooling and mounting type Cold plate or pass-through mounting
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 8BVI0220HCDS.000-3 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨