Filters
Manufacturer
Inductive Sensors
part#
description
manufacturer
NI8U-MT12-AP6X-H1141/S395
Inductive Sensor, Rated switching distance 8 mm, Non-flush, Threaded barrel, M12 x 1, Brass, PTFE-coated, Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Extended temperature range, High switching frequency, DC 3-wire, 10…30 VDC, NO contact, PNP output, M12 x 1 male connector
Turck
Quick Quote
BI10-P30SR-VP4X2
Inductive Sensor, Rated switching distance 10 mm, Flush, 2 cable entries (axial, radial), Threaded barrel, M30 x 1.5, Plastic, ABS, DC 4-wire, 10…65 VDC, Changeover contact, PNP output, Terminal chamber
Turck
Quick Quote
BI20U-CA40-AP6X2-H1141/S1590 W/BS2.1
Inductive Sensor, With WeldGuard™ Coating, Rated switching distance 20 mm, Flush, Rectangular, height 40 mm, Variable orientation of active face in 5 directions, Sensor housing GD-ALSI 12, Active face PA6-GF30, Factor 1 for all metals, Protection class IP67, Resistant to magnetic fields, DC 3-wire, 10…30 VDC, NO contact, PNP output, M12 x 1 male connector
Turck
Quick Quote
NI40R-S32SR-VP44X-H1141
Inductive Sensor, Ring Sensor, , Rectangular, height 32 mm, Plastic, ABS, Static output behavior, Sensitivity adjusted via potentiometer, Modular design, ring probe and switching amplifier also separately mountable, Output pulse length min. 100 ms, DC 4-wire, 10…55 VDC, Changeover contact, PNP output, M12 x 1 male connector
Turck
Quick Quote
NI4-Q12-RZ31X
Inductive Sensor, Rated switching distance 4 mm, Cable length (L) 2 m, Non-flush, Rectangular, height 12mm, Active face, lateral, Plastic, PA12‐GF30, AC 2-wire, 35…250 VDC, DC 2-wire, 10…300 VDC, NC contact, Cable connection
Turck
Quick Quote
BI15-Q20-2LU-H1141/S950
Inductive Sensor, For Material Recognition, Flush, Rectangular, height 20 mm, Active face on top, Plastic, PBT-GF30-V0, Analog, 1 x analog output for amplitude evaluation, 1 x analog output for phase evaluation, M12 x 1 male connector
Turck
Quick Quote
NI40-CP80-VP4X2/F2-S10
Inductive Sensor, With Increased Switching Distance, Rated switching distance 40 mm, Non-flush, Rectangular, height 41 mm, Plastic, PBT‐GF30‐V0, Large coverage, Oscillation frequency F2, DC 4-wire, 10…65 VDC, Changeover contact, PNP output, Terminal chamber
Turck
Quick Quote
BI3-M08-AP6X-H1341
Inductive Sensor, With Increased Switching Distance, Rated switching distance 3 mm, Flush, Threaded barrel, M8 x 1, Nickel-plated brass, Large sensing range, DC 3-wire, 10…30 VDC, NO contact, PNP output, M12 x 1 male connector
Turck
Quick Quote
NI5-G12K-AN6X
Inductive Sensor, Rated switching distance 5 mm, Cable length (L) 2 m, Non-flush, Threaded barrel, M12 x 1, Chrome-plated brass, DC 3-wire, 10…30 VDC, NO contact, NPN output, Cable connection
Turck
Quick Quote
BI2-EG08-AP6X 7M
Inductive Sensor, With Increased Switching Distance, Rated switching distance 2 mm, Cable length (L) 7 m, Flush, M8 × 1 threaded tube, Stainless steel, 1.4305 (AISI 303), Large sensing range, DC 3-wire, 10…30 VDC, NO contact, PNP output, Cable connection
Turck
Quick Quote
NI4-S12-AN6X
Inductive Sensor, Rated switching distance 4 mm, Cable length (L) 2 m, Non-flush, Threaded barrel, M12 x 1, Plastic, PA12‐GF30, DC 3-wire, 10…30 VDC, NO contact, NPN output, Cable connection
Turck
Quick Quote
NI30-G30K-AP6X
Inductive Sensor, With Increased Switching Distance, Rated switching distance 30 mm, Cable length (L) 2 m, Non-flush, Threaded barrel, M30 x 1.5, Short version, Chrome-plated brass, Large sensing range, DC 3-wire, 10…30 VDC, NO contact, PNP output, Cable connection
Turck
Quick Quote
BI20U-CP40-AP6X2/S10
Inductive Sensor, With Extended Switching Distance, Rated switching distance 20 mm, Flush, Rectangular, height 40 mm, Variable orientation of active face in 9 directions, Plastic, PBT‐GF30‐V0, High luminance corner LEDs, Optimum visibility of operating-voltage display and switching state in any installation position, , Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Large coverage, High switching frequency, DC 3-wire, 10…30 VDC, NO contact, PNP output, Terminal cham
Turck
Quick Quote
NI50U-CK40-VP6X2-H1141/S1120
Inductive Sensor, With Extended Switching Distance, Rated switching distance 50 mm, Non-flush, Rectangular, height 40 mm, Variable orientation of active face in 5 directions, Plastic, PBT‐GF30‐V0, High luminance corner LEDs, Optimum view on supply voltage and switching state from any position, Factor 1 for all metals, Increased switching distance, Protection class IP68, Resistant to magnetic fields, Auto-compensation protects against predamping, Partially embeddable, Special version for series c
Turck
Quick Quote
BI3-EG08FE-AN6X
Inductive Sensor, Stainless Steel Front, Rated switching distance 3 mm, Cable length (L) 2 m, Flush, Threaded barrel, M8 x 1, Stainless steel, 1.4305, DC 3-wire, 10…30 VDC, NO contact, NPN output, Cable connection
Turck
Quick Quote
NI4U-Q8SE-RP6X-V1131
Inductive Sensor, With Extended Switching Distance, Rated switching distance 4 mm, Non-flush, Rectangular, height 8 mm, Active face on top, Factor 1 for all metals, Increased switching distance, Protection class IP68, Resistant to magnetic fields, Auto-compensation protects against pre-damping, Flush mounted installation on up to 4 sides, DC 3-wire, 10…30 VDC, NC contact, PNP output, M8 x 1 male connector
Turck
Quick Quote
BI10-P30-Y1X/S97
Inductive Sensor, With Extended Temperature Range, Rated switching distance 10 mm, Cable length (L) 2 m, Flush, Threaded barrel, M30 x 1.5, Plastic, PA12‐GF30, Temperatures up to -40 °C, DC 2-wire, nom. 8.2 VDC, Output acc. to DIN EN 60947-5-6 (NAMUR), Cable connection, ATEX category II 2 G, Ex zone 1, ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 °C, SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0, SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to I
Turck
Quick Quote
BI5U-EM18-AP6X
Inductive Sensor, Rated switching distance 5 mm, Cable length (L) 2 m, Flush, Threaded barrel, M18 x 1, Stainless steel, 1.4301, Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Extended temperature range, High switching frequency, DC 3-wire, 10…30 VDC, NO contact, PNP output, Cable connection
Turck
Quick Quote
BI20-G47-ADZ30X2-B1131
Inductive Sensor, Rated switching distance 20 mm, Flush, Threaded barrel, PG36, Chrome-plated brass, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NO contact, 7/8" male connector
Turck
Quick Quote
BI2U-M12E-AD4X
Inductive Sensor, Rated switching distance 2 mm, Cable length (L) 2 m, Flush, M12 × 1 threaded barrel, Long version, Chrome-plated brass, Factor 1 for all metals, Resistant to magnetic fields, DC 2-wire, 10…65 VDC, NO contact, Cable connection
Turck
Quick Quote
Items per page: