Filters
Manufacturer
More in this category
Electrical Measuring & Monitoring Instruments
part#
description
manufacturer
2804856
Protective plug PT with protective circuit for 4 conductors of signal circuits grounded on one side. Nominal voltage: 48 V AC
Phoenix Contact
Quick Quote
2838526
LSA-PLUS plug (COMTRAB CTM) with protective circuit for 2-conductor signal circuits grounded on one side. Nominal voltage: 110 V AC
Phoenix Contact
Quick Quote
2906850
Fine surge protection with integrated status indicator for a signal wire with grounded reference potential.
Phoenix Contact
Quick Quote
2906853
Fine surge protection with integrated status indicator for a 2-wire floating signal circuit.
Phoenix Contact
Quick Quote
2906863
Coarse surge protection with integrated status indicator for a 2-wire floating signal circuit.
Phoenix Contact
Quick Quote
2906832
Fine surge protection with integrated status indicator for a signal wire with grounded reference potential.
Phoenix Contact
Quick Quote
1109689
Medium surge protection with integrated status indicator for a 2-wire floating signal circuit.
Phoenix Contact
Quick Quote
2794903
Modular terminal block with varistor as surge voltage protection between clamping connector and DIN rail, separate ground connection, nominal voltage: 24 V DC, mounting on NS 35/7.5, terminal width: 6.2 mm, terminal height: 69 mm
Phoenix Contact
Quick Quote
2906844
Coarse surge protection with integrated status indicator for a signal wire with grounded reference potential.
Phoenix Contact
Quick Quote
2794916
Modular terminal block with varistor as surge voltage protection between clamping connector and DIN rail, separate ground connection, nominal voltage: 48 V DC, mounting on NS 35/7.5, terminal width: 6.2 mm, terminal height: 69 mm
Phoenix Contact
Quick Quote
2902020
3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV and V range, unipolar as well as bipolar. Push-in connection technology, order configuration.
Phoenix Contact
Quick Quote
2901997
Two-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Phoenix Contact
Quick Quote
2906447
Single-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Phoenix Contact
Quick Quote
2906449
Two-channel output loop-powered 2-way repeater power supply with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
Phoenix Contact
Quick Quote
2902065
Constant voltage/current source with plug-in connection technology, input voltage: 9.6 V DC ... 30 V DC. Output voltage: 1.25 V DC ...10 V DC or output current: 2.5 mA ... 20 mA can be set. Configurable via DIP switch. Push-in connection technology.
Phoenix Contact
Quick Quote
2924139
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
Phoenix Contact
Quick Quote
1050192
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.
Phoenix Contact
Quick Quote
1093211
Lambrecht Meteo GmbH pyranometer for measuring the irradiation intensity in W/m² with a 180° aperture opening. The measurement value is provided via Modbus/RTU (RS-485). Corresponds to the accuracy class "First Class" in accordance with ISO 9060
Phoenix Contact
Quick Quote
1114234
PLCnext Control device based on AXC F 2152. Prepared for a customer-specific PGS controller application. Basis for the feed-in management of power generation systems that feed into medium- and high-voltage grids. Certified in accordance with VDE-AR-N 4110
Phoenix Contact
Quick Quote
1084351
SCK measuring module for monitoring photovoltaic systems, 4 x current measurement up to 20 A, 1 x digital input, interface to SCK communication moduleSCK measuring module for monitoring photovoltaic systems, 4 x current measurement up to 20 A, 1 x digital
Phoenix Contact
Quick Quote
Items per page:
Electrical Measuring & Monitoring Instruments
General Guide & Overview
Electrical measuring instruments play a crucial role in ensuring the safety and efficiency of electrical systems. From measuring voltage and current to diagnosing electrical issues, these instruments provide valuable information for maintenance and troubleshooting purposes.
There are various types of electrical measuring instruments available, each designed for specific applications. Whether you are a professional electrician, an engineer, or a DIY enthusiast, understanding these instruments is essential when working with electricity.
In this guide, we will provide an overview of different electrical measuring instruments and their functions. From multimeters to megohmmeters, we will explore the types of instruments used in electrical testing and the safety precautions associated with them.
By the end of this guide, you will have a better understanding of the various tools and devices available for measuring and monitoring electrical parameters. Whether you are a beginner or an experienced professional, this guide will serve as a valuable resource in your electrical testing journey.
Multimeter
A multimeter, also known as a Volt-Ohm meter (VOM), is a handheld device that combines multiple measurement functions, including voltage, current, resistance, and frequency, into a single unit.
The multimeter is a versatile device that can be used to test and troubleshoot electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems. Its portable and compact design makes it convenient to carry and use in different locations or on the go.
With a multimeter, you can accurately measure voltage to check if electrical circuits are delivering the expected power. It allows you to determine the current flowing through a circuit, helping you analyze the performance and efficiency of electrical devices. The resistance measurement function helps identify faulty or damaged components in a circuit, allowing for timely repairs.
In addition, a multimeter can measure frequency, which is essential for diagnosing issues in electrical systems that rely on specific frequency ranges, such as motor controls and power supplies.
With its ability to measure voltage, current, resistance, and frequency, this handheld device helps you ensure the proper functioning of electronic equipment, motor controls, domestic appliances, power supplies, and wiring systems, making it an essential addition to any toolkit.
Megohmmeter
A megohmmeter, commonly known as a "megger," is a specialized type of ohmmeter used to measure the electrical resistance of insulators. It plays a crucial role in ensuring the safety and efficiency of electrical systems. Megohmmeters are designed to accurately measure resistance values ranging from several megohms to several million megohms, allowing technicians to evaluate the insulation properties of various equipment and components.
Megohmmeters are extensively used in industries such as power generation, transmission, and distribution. They are particularly valuable for assessing the insulation integrity of critical equipment like circuit breakers, transformers, switchgear, and cables. By measuring the resistance, technicians can identify potential issues like degraded insulation, moisture ingress, or other faults that may compromise the safety and functionality of electrical systems.
Unlike standard ohmmeters, which measure low resistance values, megohmmeters utilize high voltage levels to test the insulation properties of materials. This high voltage helps to identify leaks or weak spots in the insulation and ensures that the materials meet the required safety standards. Megohmmeters provide valuable insights into the electrical health of different components, allowing technicians to diagnose problems and take preventive actions.
When using a megohmmeter, it is important to follow safety precautions and use the appropriate personal protective equipment (PPE) to protect against potential electrical hazards. Technicians should carefully follow the manufacturer's instructions and ensure that the equipment is properly calibrated and maintained for accurate measurements. By utilizing megohmmeters in regular testing and maintenance procedures, electrical systems can operate at their optimum level, ensuring reliable performance and reducing the risk of malfunctions and costly downtime.
Safety Precautions and Conclusion
Before using a multimeter or any electrical testing equipment, it is crucial to understand the necessary safety precautions and guidelines. This ensures not only the accuracy of the measurements but also the personal safety of the operator.
To begin, it is essential to check the multimeter's electrical parameters, such as voltage range and current capacity, to ensure they are suitable for the intended application. Additionally, understanding the multimeter's Category (CAT) rating is crucial in assessing its safety level for various electrical environments. The CAT rating indicates the maximum voltage and current the multimeter can safely withstand.
Furthermore, performing a visual inspection of the multimeter before use is vital. One must check for any physical damage, loose connections, or worn-out leads or probes. If any defects are identified, the multimeter should be repaired or replaced to avoid potential hazards.
When working with electricity, personal protective equipment (PPE) is essential. This may include insulating gloves, safety glasses, and non-conductive footwear. Using PPE not only protects against electrical shock but also ensures overall safety in case of accidents.
In conclusion, adhering to proper safety precautions and guidelines when using multimeters or any electrical testing equipment is of utmost importance. By considering multimeter CAT ratings, performing visual inspections, and wearing appropriate PPE, the operator can minimize the risk of electrical hazards. These preventive measures ensure the accurate and safe functioning of the multimeter, allowing for reliable measurements and effective troubleshooting in various electrical systems. Remember, safety should always be the top priority when working with electricity.
FAQ
What is electrical testing and why is it important?
Electrical testing involves applying voltage or current to a circuit and comparing the measured value to an expected result. It is important because it helps verify the calculations within a circuit and diagnose electrical issues.
What are some commonly used electrical measuring instruments?
Some commonly used electrical measuring instruments include multimeters, megohmmeters, low-resistance ohmmeters, hipotential test sets, high current test sets, secondary test sets, relay test sets, power factor test sets, and winding resistance test sets.
What is a multimeter used for?
A multimeter, also known as a Volt-Ohm meter (VOM), is a handheld device that combines multiple measurement functions, such as voltage, current, resistance, and frequency, into a single unit. It is primarily used to diagnose electrical issues in a wide range of industrial and household devices.
What is a megohmmeter used for?
A megohmmeter, commonly known as a "megger," is a specialized type of ohmmeter used to measure the electrical resistance of insulators. It is frequently used to measure the insulation of various types of equipment, including circuit breakers, transformers, switchgear, and cables.
What safety precautions should be followed when using electrical measuring instruments?
Before using any electrical testing equipment, it is important to understand the electrical parameters and safety precautions associated with them. This includes checking for appropriate CAT ratings, understanding the IP codes for dust and water resistance, and visually inspecting the meter for any physical damage. It is also crucial to take proper safety measures when working with electricity, such as using personal protective equipment (PPE) and following specific guidelines to prevent electrical hazards.