1050192 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:1050192
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1050192 Phoenix Contact price in the box on the right side or send a quick quote.
1050192 Product Details
- Height 112.5 mm
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Altitude ≤ 5000 m
- Rated insulation voltage 300 Vrms
- Sensor input current 10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
- Current output signal 0 mA ... 20 mA
- Nominal supply voltage 24 V DC
- Power consumption ≤ 1 W
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- No. of channels 1
- Status display Green LED (supply voltage, PWR)
- Electromagnetic compatibility Conformance with EMC directive
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- DNV GL-Temperature B
- DNV GL-Vibration A
- Additional text and EN 61326
- Humidity B
- Vibration A
- ECLASS 4.1 27210120
- ECLASS 6.0 27210120
- Ambient temperature (operation) 49 °C
- Degree of protection IP20
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Max. permissible overall conductor resistance 50 Ω (Per cable)
- Max. current output signal ≥ 21 mA
- Behavior in the event of a sensor error As per NE 43 or can be freely defined
- Noise emission EN 61000-6-4
- Width 12.5 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Signal output Current output
- Measuring range span ≥ 50 K
- Load/output load current output ≤ 600 Ω
- Stripping length 7 mm
- Connection method Screw connection
- Conductor cross section AWG 24 ... 14
- Step response (0–99%) typ. 1 s
- Alignment zero ± 5 %
- Housing material PA 6.6-FR
- Typical deviation from the measuring range final value 1 %
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- UNSPSC 21.0 41112105
- Depth 114.5 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Temperature measuring range -200 °C ... 850 °C (Range depending on the sensor type)
- Input signal range 0 Ω ... 50 kΩ
- Configurable/programmable Yes
- Output ripple (current) < 15 µAPP
- Power dissipation ≤ 0.76 W
- Screw thread M3
- Temperature coefficient, typical 0.01 %/K
- Transmission error, typical 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Interference emission EN 61000-6-4
- Degree of pollution 2
- Overvoltage category II
- Conformance CE-compliant, additionally EN 61326
- DNV GL-Humidity B
- DNV GL-EMC B
- Temperature B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27210129
- ECLASS 7.0 27210120
- ETIM 7.0 EC002919
- UNSPSC 12.01 39121008
- UNSPSC 20.0 41112105
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Alignment span ± 5 %
- Color gray
- Designation Safety Integrity Level (SIL, IEC 61508)
- Standards/regulations GB 3836.1
- IECEx Ex ec ic IIC T4 Gc
- ATEX II 3 G Ex ec ic IIC T4 Gc
- Certificate DNV GL TAA00000AG
- EMC B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 5.1 27210120
- ECLASS 9.0 27210129
- ETIM 2.0 EC001446
- UNSPSC 6.01 30211506
- UNSPSC 19.0 41112105
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Identification 2
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27210129
- ECLASS 4.0 27210120
- ECLASS 5.0 27210120
- ETIM 3.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 18.0 41112105
- ETIM 6.0 EC002919
- ETIM 4.0 EC001446
- UNSPSC 11 39121008
- UNSPSC 13.2 41112105
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
1050192
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨