1114234 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 1114234 PLCnext Control device based on AXC F 2152. Prepared for a customer-specific PGS controller application. Basis for the feed-in management of power generation systems that feed into medium- and high-voltage grids. Certified in accordance with VDE-AR-N 4110
Phoenix Contact

Part#:1114234

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: PLCnext Control device based on AXC F 2152. Prepared for a customer-specific PGS controller application. Basis for the feed-in management of power generation systems that feed into medium- and high-voltage grids. Certified in accordance with VDE-AR-N 4110

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1114234 Phoenix Contact price in the box on the right side or send a quick quote.

1114234 Product Details

  • Height
    126.93 mm
  • Degree of protection
    IP20
  • IoT platform
    PROFICLOUD
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    5 % ... 95 % (according to DIN EN 61131-2)
  • Ambient temperature (operation)
    -25 °C ... 60 °C up to 2000 m above mean sea level (observe derating)
  • Program memory
    8 Mbyte
  • Width
    45 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (according to DIN EN 61131-2)
  • Shock
    30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
  • Engineering tool
    PLCnext Engineer
  • Mass storage
    16 Mbyte
  • Number
    2
  • Connection method
    RJ45 jack
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • ECLASS 4.0
    27240602
  • ECLASS 5.1
    27242700
  • Operating system
    Linux
  • ECLASS 4.1
    27240602
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Note
    Notes on operation To operate the product, you will need a product-specific license based on the active power sum of the generating plant and the “Solarworx” licence. You can acquire the licenses in the PLCnext Store (for links, see the “Downloads” tab).
  • Vibration (operation)
    5g
  • Programming languages supported
    Programming in acc. with IEC 61131-3
  • Number of supported devices
    max. 63 (per station)
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
  • ECLASS 11.0
    27242207
  • ECLASS 5.0
    27242700
  • Accuracy realtime clock
    1.73 s/day = 20 ppm at 25 °C
  • Realtime clock
    Yes
  • Transmission speed
    10/100 Mbps (full duplex)
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 9.0
    27242207
  • ETIM 3.0
    EC001045
  • ETIM 7.0
    EC000236
  • Depth
    75 mm
  • Air pressure (storage/transport)
    58 kPa ... 106 kPa (up to 4500 m above mean sea level)
  • Retentive mass storage
    48 kByte (NVRAM)
  • Number of local bus devices that can be connected
    max. 63 (observe current consumption)
  • Device function
    PROFINET controller, PROFINET device
  • Weight
    215 g
  • Vibration (storage/transport)
    5g
  • ECLASS 10.0.1
    27242207
  • ETIM 4.0
    EC001435
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Interface
    Axioline F local bus
  • Update rate
    min. 1 ms (4 devices)
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ECLASS 6.0
    27242200
  • ETIM 6.0
    EC000236
  • Supports cloud computing
    yes
  • Amount of process data
    max. 8192 Bit (per station)
  • Specification
    Version 2.3
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Shock (operation)
    10g (Bump endurance test according to DIN EN 60068-2-27)
  • ECLASS 7.0
    27242207

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1114234

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo