Filters
Manufacturer
Energy Meters
part#
description
manufacturer
EBX510
Schneider Electric EBX510 is a data logger designed for DIN rail mounting, part of the ComX sub-range. It functions as an energy server and is UL compliant. This device is equipped with 4GB SDRAM and offers a variety of connectivity options including 1 Ethernet (PoE), 1 Ethernet DHCP, and 2 x RS-485 ports. Additionally, it features 6 Digital Inputs (DI) and 2 Analog Inputs (AI) for versatile data collection and monitoring tasks.
Schneider Electric
Quick Quote
BCPMSCCY63S
Schneider Electric BCPMSCCY63S, part of the BCPM sub-range, is a clip-on (bracket) mounted automation component that utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz, with 256 samples per cycle. This part provides measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. It is designed to measure power factor (total/per phase) and current.
Schneider Electric
Quick Quote
BCPMSCB84S
Schneider Electric BCPMSCB84S, part of the BCPM range, is a clip-on (bracket) mounted automation part that utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. This part boasts a measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), demand total active power (present; max values - mains only), and detection of under/overvoltage.
Schneider Electric
Quick Quote
BCPMSCB2S
Schneider Electric BCPMSCB2S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates on a network frequency of 50-60 Hz with a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. This part offers measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), and demand total active power (present; max values - mains only), along with detection of under/overvoltage.
Schneider Electric
Quick Quote
BCPMSCB1S
Schneider Electric BCPMSCB1S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. The measurement accuracy for current and voltage stands at 0.5%, while for power and energy, it is 1%. This part is equipped to measure power factor (total/per phase for mains only), frequency, voltage, current, and also features voltage sag and swell detection. Additionally, it measures active energy and active power (total/per phase for mains only), along with the demand for total active power, including present and maximum values (mains only), and detects under/overvoltage conditions.
Schneider Electric
Quick Quote
BCPMSCAY63S
Schneider Electric BCPMSCAY63S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates on a network frequency of 50-60 Hz, with a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. This part offers a measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. Its measurement functions include power factor (total/per phase), frequency, voltage, current, voltage sag and swell detection, active energy, active power (total/per phase), demand total active power (present; max values), and detection of under/overvoltage.
Schneider Electric
Quick Quote
ACUDC 243-600V-A2-P2-X5-C
AccuEnergy AcuDC 243-600V-A2-P2-X5-C : DC Power and Energy Meter, Nominal Input Voltage 600 VDC, Current Hall Effect Sensor (4-20mA/12mA±8mA) Current, 20-60 VDC, 2DI+ ±15VDC, RS485, Modbus RTU, LCD Display
Accuenergy
Quick Quote
EBX210
Schneider Electric EBX210 is a data logger designed for DIN rail mounting, falling under the ComX sub-range. It features 128MB RAM and offers a variety of connectivity options including 1 Ethernet (PoE), 1 Ethernet DHCP, and 2 x RS-485 ports. Additionally, it is equipped with 6 Digital Inputs (DI) and 2 Analog Inputs (AI). The EBX210 is UL compliant, ensuring adherence to relevant safety standards.
Schneider Electric
Quick Quote
BCPMSCBY63S
Schneider Electric BCPMSCBY63S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. This part boasts a measurement accuracy of 0.5% for both current and voltage, and 1% for power and energy. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), and demand total active power (present; max values - mains only), along with detection of under/overvoltage.
Schneider Electric
Quick Quote
BCPMSCB30S
Schneider Electric BCPMSCB30S, part of the BCPM range, is designed for clip-on (bracket) mounting and utilizes the Modbus RS485 communication protocol. It operates within a network frequency of 50-60 Hz and offers a sampling rate of 12,800 Hz at 50Hz and 15,360 Hz at 60Hz. The measurement accuracy for current and voltage is 0.5%, and for power/energy, it is 1%. Its measurement functions include power factor (total/per phase; mains only), frequency, voltage, current, voltage sag and swell detection, active energy (mains only), active power (total/per phase; mains only), demand total active power (present; max values - mains only), and detection of under/overvoltage.
Schneider Electric
Quick Quote
ACUDC 243-60V-A2-P2-X5-C-D
AccuEnergy AcuDC 243-60V-A2-P2-X5-C-D : DC Power and Energy Meter, Nominal Input Voltage 60 VDC, Current Hall Effect Sensor (4-20mA/12mA±8mA) Current, 20-60 VDC, 2DI+ ±15VDC, RS485, Modbus RTU, Datalogging, LCD Display
Accuenergy
Quick Quote