3273904 Phoenix Contact Terminal Blocks
Part#:3273904
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Distribution block, nom. voltage: 450 V, nominal current: 32 A, connection method: Push-in connection, Push-in connection, number of connections: 19, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 64.8 mm, height: 21.7 mm, color: red, mounting type:
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3273904 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of levels 1
- Color red
- Insulating material group I
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Nominal cross section 4 mm²
- Insulating material PA
- Overvoltage category III
- Open side panel No
- Finger protection guaranteed
- Oscillation, broadband noise test result Test passed
- ASD level 6.12 (m/s2)2/Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Shock duration 18 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Width 64.8 mm
- Connection in acc. with standard IEC 60998-2-2
- Min. AWG conductor cross section, flexible 20
- Internal cylindrical gage A4
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 5.0 27141120
- Potentials 1
- Degree of pollution 3
- Maximum total current 63 A
- Back of the hand protection guaranteed
- Test spectrum Service life test category 2, bogie-mounted
- Acceleration 30g
- Shock test result Test passed
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Stripping length 12 mm ... 14 mm
- Rated surge voltage 6 kV
- Nominal current IN 57 A
- Result of thermal test Test passed
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height 21.7 mm
- Conductor cross section solid max. 16 mm²
- Conductor cross section flexible max. 10 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 10 mm²
- Connection cross sections directly pluggable 0.5 mm² 16 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.0 27141120
- ECLASS 4.1 27141120
- ECLASS 6.0 27141100
- UNSPSC 6.01 30211811
- UNSPSC 20.0 39121410
- Number of connections 19
- Nominal cross section feed-in 10 mm²
- Flammability rating according to UL 94 V0
- Maximum load current 57 A
- Nominal voltage UN 450 V
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock form Half-sine
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section AWG max. 6
- Value 1 mm²
- Number of shocks per direction 3
- Static insulating material application in cold -60 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Length 28.6 mm
- Connection method Push-in connection
- Conductor cross section flexible min. 0.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 7.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 19.0 39121410
- Max. AWG conductor cross section, flexible 8
- ECLASS 5.1 27141120
- ETIM 2.0 EC000897
- ETIM 4.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 18.0 39121410
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- Connection Feed-in stage
- ETIM 6.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 7.0901 39121410
- UNSPSC 21.0 39121410
- Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm²
- ECLASS 10.0.1 27141120
- ECLASS 9.0 27141120
- Conductor cross section AWG min. 20
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- Ambient temperature (assembly) -5 °C ... 70 °C
- ETIM 7.0 EC000897
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.