3273532 Phoenix Contact Terminal Blocks

Phoenix Contact 3273532 Distribution block, Block with vertical alignment, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 800 V, nominal current: 32 A, connection method: Push-in connection, n
Phoenix Contact

Part#:3273532

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Distribution block, Block with vertical alignment, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 800 V, nominal current: 32 A, connection method: Push-in connection, n

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273532 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Potentials
    1
  • Rated surge voltage
    6 kV
  • Nominal current IN
    32 A
  • Back of the hand protection
    guaranteed
  • Bending test rotation speed
    10 rpm
  • Insulating material group
    I
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141120
  • ECLASS 6.0
    27141100
  • ETIM 2.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Overvoltage category
    III
  • Nominal voltage UN
    800 V
  • Power frequency withstand voltage setpoint
    2 kV
  • Bending test turns
    135
  • Setpoint
    5 N
  • Conductor cross section solid min.
    0.5 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.75 mm²
  • Connection cross sections directly pluggable
    0.5 mm² 6 mm² 20 10
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 9.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 19.0
    39121410
  • Note
    Notes on operation The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories
  • Color
    yellow
  • Nominal cross section
    4 mm²
  • Degree of pollution
    3
  • Maximum load current
    41 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Tensile test result
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.72 kA
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Conductor cross section flexible min.
    0.2 mm²
  • Min. AWG conductor cross section, flexible
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 4.0
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • UNSPSC 18.0
    39121410
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    1.02 W (the value is based on one connection block and is multiplied according to the pin assignment)
  • Open side panel
    No
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Acceleration
    30g
  • Shock duration
    18 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Length
    58.1 mm
  • Conductor cross section solid max.
    6 mm²
  • Max. AWG conductor cross section, flexible
    12
  • Internal cylindrical gage
    A4
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 7.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 11
    39121410
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock test result
    Test passed
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG max.
    10
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.1
    27141120
  • ECLASS 5.0
    27141120
  • UNSPSC 6.01
    30211811
  • ETIM 6.0
    EC000897
  • UNSPSC 20.0
    39121410
  • Insulating material
    PA
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test duration per axis
    5 h
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Number of connections
    6
  • Finger protection
    guaranteed
  • Result of aging test
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    32.4 mm
  • Maximum total current
    63 A
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock form
    Half-sine
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Connection method
    Push-in connection
  • Tight fit on carrier
    NS 35
  • Conductor cross section short circuit testing
    6 mm²
  • ASD level
    6.12 (m/s2)2/Hz
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Width
    28.6 mm
  • Height NS 15
    30.4 mm

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo