3273260 Phoenix Contact Terminal Blocks

Phoenix Contact 3273260 Distribution block, Block with horizontal alignment and integrated supply, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection metho
Phoenix Contact

Part#:3273260

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Distribution block, Block with horizontal alignment and integrated supply, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection metho

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273260 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Nominal cross section feed-in
    6 mm²
  • Number of levels
    1
  • Nominal cross section
    2.5 mm²
  • Insulating material
    PA
  • Maximum load current
    57 A (with 10 mm² conductor cross section)
  • Nominal voltage UN
    690 V
  • Back of the hand protection
    guaranteed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Oscillation, broadband noise test result
    Test passed
  • Acceleration
    30g
  • Number of shocks per direction
    3
  • Width
    56.5 mm
  • Number of connections
    19
  • Insulating material group
    I
  • Nominal current IN
    41 A (with 6 mm² conductor cross section)
  • Finger protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Result of voltage-drop test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of aging test
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    45.7 mm
  • Conductor cross section solid min.
    1 mm²
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 4.0
    27141121
  • UNSPSC 6.01
    30211811
  • UNSPSC 13.2
    39121410
  • Connection
    Feed-in stage
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141120
  • ECLASS 7.0
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 19.0
    39121410
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG max.
    8
  • Max. AWG conductor cross section, flexible
    10
  • Value
    1 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 21.0
    39121410
  • Flammability rating according to UL 94
    V0
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of flexion and pull-out test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Color
    orange
  • Overvoltage category
    III
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Tensile test result
    Test passed
  • Short-time current
    1.2 kA
  • Test duration per axis
    5 h
  • Shock duration
    18 ms
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60947-7-1
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • ETIM 3.0
    EC000897
  • Rated surge voltage
    8 kV
  • Maximum total current
    57 A (with 10 mm² conductor cross section)
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 35
  • Result of thermal test
    Test passed
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    30.9 mm
  • ECLASS 6.0
    27141100
  • Degree of pollution
    3
  • Maximum power dissipation for nominal condition
    1.31 W (the value is based on one connection block and is multiplied according to the pin assignment)
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Setpoint
    5 N
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Connection method
    Push-in connection
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 10.0.1
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 18.0
    39121410
  • Potentials
    1
  • Bending test turns
    135
  • Conductor cross section short circuit testing
    10 mm²
  • ASD level
    6.12 (m/s2)2/Hz
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Conductor cross section AWG min.
    20
  • Min. AWG conductor cross section, flexible
    20
  • Connection cross sections directly pluggable
    1 mm² 10 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • ECLASS 11.0
    27141120
  • ECLASS 5.1
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Internal cylindrical gage
    A3
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141121
  • UNSPSC 20.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo