3273122 Phoenix Contact Terminal Blocks
Part#:3273122
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 313
Nov 25, 2024
Distribution block, Block with vertical alignment and integrated supply, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection method:
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3273122 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Finger protection guaranteed
- Nominal cross section feed-in 6 mm²
- Insulating material PA
- Maximum power dissipation for nominal condition 1.31 W (the value is based on one connection block and is multiplied according to the pin assignment)
- Maximum load current 57 A (with 10 mm² conductor cross section)
- Note The max. load current must not be exceeded by the total current of all connected conductors.
- Number of connections 19
- Color white
- Nominal voltage UN 690 V
- Back of the hand protection guaranteed
- Bending test rotation speed 10 rpm
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Shock test result Test passed
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section AWG min. 20
- Max. AWG conductor cross section, flexible 10
- Connection Feed-in stage
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 6.0 27141100
- ECLASS 5.0 27141120
- UNSPSC 7.0901 39121410
- UNSPSC 20.0 39121410
- Potentials 1
- Flammability rating according to UL 94 V0
- Rated surge voltage 8 kV
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of surge voltage test Test passed
- Result of flexion and pull-out test Test passed
- Tensile test result Test passed
- Setpoint 5 N
- Conductor cross section short circuit testing 10 mm²
- Test spectrum Service life test category 2, bogie-mounted
- ASD level 6.12 (m/s2)2/Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 15 30.4 mm
- Conductor cross section AWG max. 8
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 5.1 27141120
- ETIM 6.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 21.0 39121410
- Number of levels 1
- Overvoltage category III
- Maximum total current 57 A (with 10 mm² conductor cross section)
- Open side panel No
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test conductor cross section/weight 0.5 mm² / 0.3 kg
- Tight fit on carrier NS 35
- Short circuit stability result Test passed
- Ageing test for screwless modular terminal block temperature cycles 192
- Result of aging test Test passed
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock form Half-sine
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Length 58.1 mm
- Width 28.6 mm
- Conductor cross section solid min. 1 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- Internal cylindrical gage A3
- Value 1 mm²
- ECLASS 4.0 27141121
- ECLASS 7.0 27141120
- UNSPSC 6.01 30211811
- UNSPSC 11 39121410
- Nominal cross section 2.5 mm²
- Degree of pollution 3
- Insulating material group I
- Nominal current IN 41 A (with 6 mm² conductor cross section)
- Result of power-frequency withstand voltage test Test passed
- Bending test turns 135
- Result of voltage-drop test Test passed
- Result of temperature-rise test Test passed
- Short-time current 1.2 kA
- Test duration per axis 5 h
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Number of shocks per direction 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/7,5 32.4 mm
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section solid max. 10 mm²
- Conductor cross section flexible min. 0.5 mm²
- Connection cross sections directly pluggable 1 mm² 10 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 11.0 27141120
- ETIM 3.0 EC000897
- ETIM 7.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 19.0 39121410
- Result of tight fit on support Test passed
- Result of thermal test Test passed
- Oscillation, broadband noise test result Test passed
- Acceleration 30g
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 18 ms
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Stripping length 10 mm ... 12 mm
- Min. AWG conductor cross section, flexible 20
- Conductor cross section flexible max. 10 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- ECLASS 10.0.1 27141120
- ECLASS 4.1 27141121
- ECLASS 9.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 18.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$8.83
Stock:
313
Select Qty:
$8.83
$8.83 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨