Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3273114 Phoenix Contact Terminal Blocks

Phoenix Contact 3273114 Distribution block, Block with vertical alignment and integrated supply, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection method:
Phoenix Contact

Part#:3273114

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 945

Nov 22, 2024

Distribution block, Block with vertical alignment and integrated supply, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection method:

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273114 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Potentials
    1
  • Nominal cross section feed-in
    6 mm²
  • Degree of pollution
    3
  • Maximum load current
    57 A (with 10 mm² conductor cross section)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Conductor cross section short circuit testing
    10 mm²
  • Oscillation, broadband noise test result
    Test passed
  • Shock test result
    Test passed
  • Shock form
    Half-sine
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Color
    red
  • Nominal current IN
    41 A (with 6 mm² conductor cross section)
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test rotation speed
    10 rpm
  • Result of voltage-drop test
    Test passed
  • Number of levels
    1
  • Insulating material
    PA
  • Maximum power dissipation for nominal condition
    1.31 W (the value is based on one connection block and is multiplied according to the pin assignment)
  • Nominal voltage UN
    690 V
  • Finger protection
    guaranteed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Tight fit on carrier
    NS 35
  • Short-time current
    1.2 kA
  • Result of thermal test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Acceleration
    30g
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Width
    28.6 mm
  • Number of connections
    19
  • Nominal cross section
    2.5 mm²
  • Rated surge voltage
    8 kV
  • Maximum total current
    57 A (with 10 mm² conductor cross section)
  • Back of the hand protection
    guaranteed
  • Bending test turns
    135
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Result of aging test
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock duration
    18 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height NS 35/7,5
    32.4 mm
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG min.
    20
  • Value
    1 mm²
  • Flammability rating according to UL 94
    V0
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Result of power-frequency withstand voltage test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60947-7-1
  • Max. AWG conductor cross section, flexible
    10
  • Connection cross sections directly pluggable
    1 mm² 10 mm²
  • Insulating material group
    I
  • Setpoint
    5 N
  • ASD level
    6.12 (m/s2)2/Hz
  • Test duration per axis
    5 h
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Static insulating material application in cold
    -60 °C
  • Height NS 15
    30.4 mm
  • Conductor cross section solid min.
    1 mm²
  • Length
    58.1 mm
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141120
  • ECLASS 5.1
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 13.2
    39121410
  • Result of flexion and pull-out test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Number of shocks per direction
    3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • Connection
    Feed-in stage
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 18.0
    39121410
  • Overvoltage category
    III
  • Short circuit stability result
    Test passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Internal cylindrical gage
    A3
  • ECLASS 4.0
    27141121
  • ECLASS 6.0
    27141100
  • ECLASS 7.0
    27141120
  • UNSPSC 11
    39121410
  • UNSPSC 21.0
    39121410
  • Min. AWG conductor cross section, flexible
    20
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 4.1
    27141121
  • ETIM 6.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$8.83

Stock:

945

Select Qty:

$8.83

$8.83 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo