Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2904953 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2904953 Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Phoenix Contact

Part#:2904953

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904953 Phoenix Contact price in the box on the right side or send a quick quote.

2904953 Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Rated control supply current IS
    typ. 42 mA
  • Inrush current
    min. 3 mA
  • Protective circuit
    Surge protection Suppressor diode
  • Number of inputs
    1
  • Max. permissible overall conductor resistance
    150 Ω
  • Contact type
    1 enabling current path
  • Switching capacity
    min. 60 mW
  • Relay type
    Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Nominal operating mode
    100% operating factor
  • Degree of protection
    IP20
  • Depth
    102.5 mm
  • Rated control circuit supply voltage US
    24 V DC -15 % / +10 %
  • Input name
    Start circuit
  • Description of the input
    non-safety-related
  • Input voltage range "1" signal
    20.4 V DC ... 26.4 V DC
  • Contact material
    AgSnO2
  • Output fuse
    6 A gL/gG (N/O contact)
  • Recovery time
    < 500 ms
  • Min. degree of protection of inst. location
    IP54
  • Operating voltage display
    1 x green LED
  • Safety Integrity Level (SIL)
    3
  • Standards/regulations
    DIN EN 50178
  • ECLASS 10.0.1
    27371819
  • ECLASS 4.1
    40020600
  • ECLASS 7.0
    27371819
  • UNSPSC 19.0
    39122205
  • Ambient temperature (operation)
    -40 °C ... 60 °C (observe derating)
  • Power consumption at US
    typ. 1 W
  • Input current range "0" signal
    0 mA ... 2 mA (for safe Off; at S12)
  • Output description
    safety-related N/O contacts
  • Switching voltage
    min. 12 V AC/DC
  • Mechanical service life
    10x 106 cycles
  • Net weight
    69 g
  • Housing material
    PBT
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Stripping length
    12 mm
  • Safety Integrity Level Claim Limit (SIL CL)
    3
  • Degree of pollution
    2
  • Conformance
    CE-compliant
  • ECLASS 11.0
    27371819
  • ECLASS 5.0
    27371900
  • ETIM 6.0
    EC001449
  • UNSPSC 21.0
    39122205
  • Width
    6.8 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Filter time
    max. 1.5 ms (at S12, S22; test pulse width)
  • Current consumption
    < 10 mA
  • Protective circuit/component
    Suppressor diode
  • Sq. Total current
    36 A2 (observe derating)
  • Switching frequency
    max. 0.5 Hz
  • Typical response time at US
    < 175 ms
  • Mounting type
    DIN rail mounting
  • Connection method
    Screw connection
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Performance level (PL)
    e (4 A DC13; 5 A AC15; 8760 switching cycles/year)
  • Overvoltage category
    III
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27371800
  • ECLASS 5.1
    27371900
  • ETIM 7.0
    EC001449
  • Height
    93.1 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Designation
    Air clearances and creepage distances between the power circuits
  • Input voltage range "0" signal
    0 V DC ... 5 V DC (for safe Off; at S12)
  • Output name
    Enabling current path
  • Number of outputs
    1 (undelayed)
  • Limiting continuous current
    6 A (observe derating)
  • Typical release time at US
    < 20 ms (when controlled via A1 or S12 and S22.)
  • Mounting position
    vertical or horizontal
  • Status display
    2 x green LEDs
  • pluggable
    no
  • Stop category
    0
  • Category
    4
  • Rated surge voltage/insulation
    Safe isolation, reinforced insulation 6 kV between input circuit and enabling current pathBasic insulation 4 kV between all current paths and housing
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 4.0
    40020600
  • UNSPSC 13.2
    39121501
  • UNSPSC 20.0
    39122205
  • Housing color
    yellow
  • Conductor cross-section AWG
    24 ... 12
  • Screw thread
    M3
  • Rated insulation voltage
    250 V AC
  • Shock
    15g
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 9.0
    27371819
  • UNSPSC 18.0
    39122205

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2904953

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo