2904602

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/20 A

  • Product Details
  • Relevant Products
Phoenix Contact 2904602 Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/20 A
Phoenix Contact

2904602

1-year warranty
Product Lifecycle: Active

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/20 A

Phoenix Contact

Product Details

Additional Documents

Test level 5
16.7 Hz 50 Hz 60 Hz (Test Level 4)
Signals (test level 1)
100 kHz 1 MHz (Test Level 3 - symmetrical)
Width
70 mm
Height with alternative assembly
130 mm
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Climatic class
3K3 (in acc. with EN 60721)
Nominal input voltage range
100 V AC ... 240 V AC
Discharge current to PE
< 3.5 mA
Mains buffering time
typ. 28 ms (120 V AC)
Nominal output voltage
24 V DC
Dynamic Boost (IDyn.Boost)
30 A (5 s)
Derating
> 60 °C ... 70 °C (2.5%/K)
Net weight
1.3 kg
Input, output (test level 3)
100 kHz 1 MHz (Test Level 3 - asymmetrical)
Input, output (test level 1)
100 kHz 1 MHz (Test Level 3 - symmetrical)
ECLASS 11.0
27040701
ECLASS 9.0
27040701
UNSPSC 19.0
39121004
Dielectric strength maximum
300 V AC 60 s
Current consumption
6.8 A (100 V AC)
Input, output (test level 1)
100 kHz 1 MHz (Test Level 3 - symmetrical)
ECLASS 11.0
27040701
ECLASS 9.0
27040701
UNSPSC 19.0
39121004
Dielectric strength maximum
300 V AC 60 s
Current consumption
6.8 A (100 V AC)
Recommended breaker for input protection
10 A ... 16 A (Characteristic B, C, D, K or comparable)
Nominal output current (IN)
20 A
Feedback voltage resistance
≤ 35 V DC
Power loss nominal load max.
< 40 W (120 V AC)
Maximum power dissipation in no-load condition
< 5 W (120 V AC)
Width with alternative assembly
122 mm
Depth with alternative assembly
73 mm
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Insulation voltage input/output
4 kV AC (type test)
Connection method
Push-in connection
Conductor cross section AWG max.
16
Standard - safety for equipment for measurement, control, and laboratory use
IEC 61010-1
Standard - Safe isolation
IEC 61558-2-16 pending
SIQ
BG (type approved)
Shipbuilding approval
DNV GL, PRS, BV, LR, ABS
DNV GL conducted interference
Class A
Attenuated oscillating wave
EN 61000-4-18
Input, output (test level 2)
10 MHz
Criterion A
Normal operating behavior within the specified limits.
ECLASS 7.0
27049002
UNSPSC 18.0
39121004
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
Noise emission
EN 55016
DNV GL noise radiation
Class B
Discharge in air
15 kV (Test Level 4)
I/O/S
asymmetrical
Pulse-shape magnetic field
EN 61000-4-9
Test level 1
15 Hz 150 Hz (Test Level 4)
Test level 3
1.5 kHz 15 kHz (Test Level 4)
Test level 6
150 Hz 180 Hz (Test Level 4)
Insulation voltage input / PE
2.5 kV AC (type test)
Conductor cross section solid max.
1 mm²
EMC requirements for noise immunity
EN 61000-6-1
EMC requirements, power plant
IEC 61850-3
Standard – Limitation of mains harmonic currents
EN 61000-3-2
UL approvals
UL Listed UL 508
Criterion C
Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
ECLASS 5.1
27242213
ECLASS 10.0.1
27040701
Signals (test level 2)
100 kHz 1 MHz (Test Level 3 - asymmetrical)
China RoHS
Environmentally Friendly Use Period = 25;
ETIM 6.0
EC002540
UNSPSC 20.0
39121004
Attenuated sinusoidal oscillations (ring wave)
EN 61000-4-12
Test level 7
16.7 Hz 50 Hz 60 Hz (Test Level 4)
Criterion B
Temporary impairment to operational behavior that is corrected by the device itself.
REACh SVHC
Lead 7439-92-1
ECLASS 6.0
27049005
UNSPSC 13.2
39121004
UNSPSC 21.0
39121004
Height
130 mm
Inflammability class in acc. with UL 94 (housing / terminal blocks)
V0
Degree of pollution
2
AC frequency range
50 Hz ... 60 Hz -10 % ... +10 %
Nominal power consumption
520 VA
Type of protection
Transient surge protection
Protection against overvoltage at the output (OVP)
≤ 32 V DC
Environmental protection directive
RoHS Directive 2011/65/EU
Assembly instructions
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Conductor cross section solid min.
0.2 mm²
Mains variation/undervoltage
SEMI F47-0706, EN 61000-4-11
Depth
125 mm
Installation height
≤ 5000 m (> 2000 m, observe derating)
Frequency range (fN)
50 Hz ... 60 Hz -10 % ... +10 %
Input fuse
12 A (slow-blow, internal)
Connection in series
yes
Degree of protection
IP20
Ambient temperature (start-up type tested)
-40 °C
Typical response time
300 ms (from SLEEP MODE)
Efficiency
typ. 92.4 % (120 V AC)
Protection class
I
Conductor cross section AWG min.
24
Standard – Safety extra-low voltage
IEC 61010-1 (SELV)
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Comments
Criterion A
Signal
4 kV (Test Level 4 - asymmetrical)
Voltage
2.5 kV
Voltage dip
0 %
Damped oscillating magnetic field
EN 61000-4-10
Test level 2
150 Hz 1.5 kHz (Test Level 4)
Installation distance right/left
5 mm / 5 mm
Input voltage range
100 V AC ... 240 V AC -15 % ... +10 %
Protective circuit/component
Varistor, gas-filled surge arrester
Static Boost (IStat.Boost)
25 A
Connection in parallel
Yes, for redundancy and increased capacity
Control deviation
< 0.5 % (Static load change 10 % ... 90 %)
Output power
480 W
MTBF (IEC 61709, SN 29500)
> 1112000 h (25 °C)
Insulation voltage output / PE
0.5 kV DC (type test)
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
1.5 mm²
HART FSK Physical Layer Test Specification Compliance
Output voltage UOut compliant
Rail applications
EN 50121-3-2
Harmonic currents
EN 61000-3-2
Additional text
Test Level 2
Frequency range
50 Hz ... 60 Hz
Fast transients (burst)
EN 61000-4-4
Surge voltage load (surge)
EN 61000-4-5
Voltage dips
EN 61000-4-11
Power frequency magnetic field
EN 61000-4-8
Installation distance top/bottom
50 mm / 50 mm
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Inrush current
typ. 11 A (at 25 °C)
Power factor (cos phi)
0.98
Setting range of the output voltage (USet)
24 V DC ... 29.5 V DC (constant capacity)
Selective Fuse Breaking (ISFB)
120 A (15 ms)
Residual ripple
< 50 mVPP (with nominal values)
Mounting position
horizontal DIN rail NS 35, EN 60715
Stripping length
8 mm
EMC requirements for noise emission
EN 61000-6-3
Standard - Safety of transformers
IEC 61558-2-16 pending
Standard - Electrical safety
IEC 61010-2-201 (SELV)
Standard - power supply devices for low voltage with DC output
EN 61204-3
Contact discharge
8 kV (Test Level 4)
Electrostatic discharge
EN 61000-4-2
Input
2 kV (Test Level 4 - symmetrical)
Output
1 kV (Test Level 3 - symmetrical)
Frequency
50 Hz
Number of periods
0,5 / 1 / 5 / 50 / 250 periods
Asymmetrical conducted disturbance variables
EN 61000-4-16
CSA
CAN/CSA-C22.2 No. 60950-1-07
Conducted noise emission
EN 55016
Flicker
EN 61000-3-3
Electromagnetic HF field
EN 61000-4-3
Test field strength
110 A/m
Conducted interference
EN 61000-4-6
Test level 4
15 kHz 150 kHz (Test Level 4)

Relevant products

Responsive Customer Support with personalized assistance

Efficient Shipping and Delivery Worldwide

Secure Payment Processing with money back guarantee

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo