Phoenix Contact 2904602 Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/20 A
Phoenix Contact

Part#:2904602

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 24 V DC/20 A

About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2904602 Phoenix Contact price in the box on the right side or send a quick quote.

2904602 Product Details

  • Test level 5
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • Width
    70 mm
  • Height with alternative assembly
    130 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Discharge current to PE
    < 3.5 mA
  • Mains buffering time
    typ. 28 ms (120 V AC)
  • Nominal output voltage
    24 V DC
  • Dynamic Boost (IDyn.Boost)
    30 A (5 s)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Net weight
    1.3 kg
  • Input, output (test level 3)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • ECLASS 11.0
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004
  • Dielectric strength maximum
    300 V AC 60 s
  • Current consumption
    6.8 A (100 V AC)
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristic B, C, D, K or comparable)
  • Nominal output current (IN)
    20 A
  • Feedback voltage resistance
    ≤ 35 V DC
  • Power loss nominal load max.
    < 40 W (120 V AC)
  • Maximum power dissipation in no-load condition
    < 5 W (120 V AC)
  • Width with alternative assembly
    122 mm
  • Depth with alternative assembly
    73 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Insulation voltage input/output
    4 kV AC (type test)
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    16
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Standard - Safe isolation
    IEC 61558-2-16 pending
  • SIQ
    BG (type approved)
  • Shipbuilding approval
    DNV GL, PRS, BV, LR, ABS
  • DNV GL conducted interference
    Class A
  • Attenuated oscillating wave
    EN 61000-4-18
  • Input, output (test level 2)
    10 MHz
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 7.0
    27049002
  • UNSPSC 18.0
    39121004
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Noise emission
    EN 55016
  • DNV GL noise radiation
    Class B
  • Discharge in air
    15 kV (Test Level 4)
  • I/O/S
    asymmetrical
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 1
    15 Hz 150 Hz (Test Level 4)
  • Test level 3
    1.5 kHz 15 kHz (Test Level 4)
  • Test level 6
    150 Hz 180 Hz (Test Level 4)
  • Insulation voltage input / PE
    2.5 kV AC (type test)
  • Conductor cross section solid max.
    1 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • EMC requirements, power plant
    IEC 61850-3
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • UL approvals
    UL Listed UL 508
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 5.1
    27242213
  • ECLASS 10.0.1
    27040701
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 3 - asymmetrical)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ETIM 6.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 7
    16.7 Hz 50 Hz 60 Hz (Test Level 4)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27049005
  • UNSPSC 13.2
    39121004
  • UNSPSC 21.0
    39121004
  • Height
    130 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Degree of pollution
    2
  • AC frequency range
    50 Hz ... 60 Hz -10 % ... +10 %
  • Nominal power consumption
    520 VA
  • Type of protection
    Transient surge protection
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section solid min.
    0.2 mm²
  • Mains variation/undervoltage
    SEMI F47-0706, EN 61000-4-11
  • Depth
    125 mm
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Input fuse
    12 A (slow-blow, internal)
  • Connection in series
    yes
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Typical response time
    300 ms (from SLEEP MODE)
  • Efficiency
    typ. 92.4 % (120 V AC)
  • Protection class
    I
  • Conductor cross section AWG min.
    24
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Comments
    Criterion A
  • Signal
    4 kV (Test Level 4 - asymmetrical)
  • Voltage
    2.5 kV
  • Voltage dip
    0 %
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 2
    150 Hz 1.5 kHz (Test Level 4)
  • Installation distance right/left
    5 mm / 5 mm
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Static Boost (IStat.Boost)
    25 A
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Output power
    480 W
  • MTBF (IEC 61709, SN 29500)
    > 1112000 h (25 °C)
  • Insulation voltage output / PE
    0.5 kV DC (type test)
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • HART FSK Physical Layer Test Specification Compliance
    Output voltage UOut compliant
  • Rail applications
    EN 50121-3-2
  • Harmonic currents
    EN 61000-3-2
  • Additional text
    Test Level 2
  • Frequency range
    50 Hz ... 60 Hz
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage dips
    EN 61000-4-11
  • Power frequency magnetic field
    EN 61000-4-8
  • Installation distance top/bottom
    50 mm / 50 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Inrush current
    typ. 11 A (at 25 °C)
  • Power factor (cos phi)
    0.98
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (constant capacity)
  • Selective Fuse Breaking (ISFB)
    120 A (15 ms)
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Stripping length
    8 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safety of transformers
    IEC 61558-2-16 pending
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Contact discharge
    8 kV (Test Level 4)
  • Electrostatic discharge
    EN 61000-4-2
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Frequency
    50 Hz
  • Number of periods
    0,5 / 1 / 5 / 50 / 250 periods
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Conducted noise emission
    EN 55016
  • Flicker
    EN 61000-3-3
  • Electromagnetic HF field
    EN 61000-4-3
  • Test field strength
    110 A/m
  • Conducted interference
    EN 61000-4-6
  • Test level 4
    15 kHz 150 kHz (Test Level 4)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo