2904597 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904597 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 1.3 A
Phoenix Contact

Part#:2904597

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 8

Apr 26, 2024

About the product: Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 1.3 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904597 Phoenix Contact price in the box on the right side or send a quick quote.

2904597 Product Details

  • Test field strength
    1000 A/m
  • Width
    22.5 mm
  • Installation distance top/bottom (passive)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Inrush current
    typ. 5.9 A (at 25 °C)
  • Dynamic Boost (IDyn.Boost)
    2.6 A (≤ 60 °C (5 s))
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Output power
    30 W
  • Net weight
    0.188 kg
  • Assembly instructions
    DIN rail mounting
  • Connection method
    Screw connection
  • Conductor cross section AWG max.
    14
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Contact discharge
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • Output
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Voltage dip
    0 %
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • ECLASS 10.0.1
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004
  • Depth
    90 mm
  • Installation distance top/bottom (active)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (start-up type tested)
    -40 °C
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Current consumption
    0.46 A (100 V AC)
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Connection in series
    yes
  • Typical response time
    500 ms
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Conducted noise emission
    EN 55016
  • Conducted interference
    EN 61000-4-6
  • Frequency
    60 Hz
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 2)
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • UNSPSC 13.2
    39121004
  • Height
    99 mm
  • Installation distance right/left (active)
    15 mm / 15 mm (POut ≥50% )
  • Degree of protection
    IP20
  • Degree of pollution
    2
  • Dielectric strength maximum
    300 V AC 30 s
  • Mains buffering time
    typ. 43 ms (120 V AC)
  • Type of protection
    Transient surge protection
  • Static Boost (IStat.Boost)
    1.625 A (≤ 40 °C)
  • Feedback voltage resistance
    ≤ 35 V DC
  • Residual ripple
    < 40 mVPP (with nominal values)
  • Power loss nominal load max.
    < 3.7 W (120 V AC)
  • Efficiency
    typ. 89.2 % (120 V AC)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG min.
    26
  • Standard - Safety of transformers
    EN 61558-2-16
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • ECLASS 5.1
    27242213
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Discharge in air
    8 kV (Test Level 3)
  • Frequency range
    50 Hz ... 60 Hz
  • Fast transients (burst)
    EN 61000-4-4
  • Additional text
    Test Level 2
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ETIM 6.0
    EC002540
  • ETIM 7.0
    EC002540
  • Installation distance top/bottom (active, passive)
    30 mm / 30 mm (POut ≤50 %)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Input fuse
    3.15 A (slow-blow, internal)
  • Nominal output voltage
    24 V DC
  • Nominal output current (IN)
    1.3 A
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • MTBF (IEC 61709, SN 29500)
    > 1904000 h (25 °C)
  • Conductor cross section flexible min.
    0.14 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safe isolation
    IEC 61558-2-16
  • UL approvals
    UL Listed UL 61010-1
  • Noise emission
    EN 55016
  • Signal
    0.5 kV (Test Level 2 - symmetrical)
  • Power frequency magnetic field
    EN 61000-4-8
  • Voltage dips
    EN 61000-4-11
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ECLASS 7.0
    27049002
  • UNSPSC 20.0
    39121004
  • ECLASS 6.0
    27049000
  • Installation distance right/left (passive)
    5 mm / 5 mm (POut ≥50% )
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Nominal power consumption
    37 VA
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C or comparable)
  • Derating
    > 60 °C (2.5%/K)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Maximum power dissipation in no-load condition
    < 0.4 W (230 V AC)
  • Protection class
    II
  • Conductor cross section solid min.
    0.14 mm²
  • Stripping length
    8 mm
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    2 kV (symmetrical)
  • Voltage
    300 V (1 s)
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Criterion A
    Normal operating behavior within the specified limits.
  • UNSPSC 18.0
    39121004
  • UNSPSC 21.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$90.85

2904597

Stock:

8

Select Qty:

$90.85

$90.85 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo