2320908 Phoenix Contact AC/DC Power Supplies
Part#:2320908
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 28
Nov 21, 2024
Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, with protective coating, input: 1-phase, output: 24 V DC/5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2320908 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height with alternative assembly 130 mm
- Degree of pollution 2
- Frequency range DC 0 Hz
- Input voltage range 85 V AC ... 264 V AC
- Current consumption 1.2 A (120 V AC)
- Protective circuit/component Varistor
- POWER BOOST (IBoost) 7.5 A (-25°C ... 40°C permanent, UOUT = 24 V DC )
- Feedback voltage resistance max. 35 V DC
- Residual ripple < 40 mVPP (with nominal values)
- Insulation voltage input / PE 3.5 kV AC (type test)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Degree of protection IP20
- Discharge current to PE < 3.5 mA
- Inrush current < 15 A
- Input fuse 5 A (slow-blow, internal)
- Nominal output current (IN) 5 A (-25 °C ... 60 °C, UOUT = 24 V DC)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Power loss nominal load max. 15 W
- Efficiency > 90 % (for 230 V AC and nominal values)
- Net weight 0.7 kg
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Nominal input voltage range 100 V AC ... 240 V AC
- AC frequency range 45 Hz ... 65 Hz
- Nominal power consumption 141 VA
- Type of protection Transient surge protection
- Nominal output voltage 24 V DC ±1 %
- Connection in parallel Yes, for redundancy and increased capacity
- Connection in series yes
- Output power 120 W
- Maximum power dissipation in no-load condition 3 W
- MTBF (IEC 61709, SN 29500) > 1134000 h (25 °C)
- Insulation voltage output / PE 500 V DC (routine test)
- Connection method Pluggable screw connection
- Screw thread M3
- Conductor cross section AWG min. 20
- Contact discharge 4 kV (Test Level 2)
- Frequency range 0.15 MHz ... 80 MHz
- Comments Criterion B
- Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
- Certificate IEC 60950-1 (2nd Edition)
- Rail applications EN 50121-4
- IECEx Ex nA nC IIC T4 Gc
- ECLASS 5.1 27049000
- ECLASS 7.0 27049002
- ECLASS 9.0 27040701
- ETIM 6.0 EC002540
- UNSPSC 11 39121004
- UNSPSC 13.2 39121004
- Dielectric strength maximum 300 V AC
- Recommended breaker for input protection 6 A ... 16 A (AC: Characteristics B, C, D, K)
- Mains buffering time typ. 55 ms (120 V AC)
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- Typical response time < 0.15 s
- Insulation voltage input/output 4 kV AC (type test)
- Protection class I
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 7 mm
- Noise immunity EN 61000-6-2:2005
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Standards/regulations EN 61000-6-3
- Low Voltage Directive Conformance with LV directive 2006/95/EC
- Standard - Equipment safety BG (design tested)
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- DeviceNet approval DeviceNet™ Power Supply Conformance Tested
- ATEX II 3 G Ex nA nC IIC T4 Gc
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27049000
- ECLASS 5.0 27049000
- ETIM 4.0 EC000599
- ETIM 7.0 EC002540
- ETIM 5.0 EC002540
- UNSPSC 12.01 39121004
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section AWG max. 12
- Noise emission EN 55011 (EN 55022)
- Connection in acc. with standard CSA
- Test field strength 3 V/m (Test Level 2)
- Shipbuilding approval DNV GL (EMC A)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- UL approvals UL/C-UL listed UL 508
- Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706 Compliance Certificate
- Noxious gas test ISA-S71.04-1985 G3 Harsh Group A
- Overvoltage category (EN 62477-1) III
- ECLASS 4.0 27040700
- ECLASS 4.1 27040700
- ECLASS 8.0 27049002
- UNSPSC 6.01 30211502
- UNSPSC 7.0901 39121004
- Width with alternative assembly 122 mm
- Depth 125 mm
- Installation height 5000 m
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Selective Fuse Breaking (ISFB) 30 A (12 ms)
- Protection against overvoltage at the output (OVP) < 32 V DC
- Voltage 10 V (Test Level 3)
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Max. permissible relative humidity (operation) 100 % (at 25 °C, non-condensing)
- Derating 60 °C ... 70 °C (2.5%/K)
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Width 40 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Height 130 mm
- Depth with alternative assembly 43 mm
- Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Standard - Safe isolation DIN VDE 0100-410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$534.63
Stock:
28
Select Qty:
$534.63
$534.63 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨