Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2866802 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2866802 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 3-phase, output: 24 V DC / 40 A
Phoenix Contact

Part#:2866802

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 2

Nov 5, 2024

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 3-phase, output: 24 V DC / 40 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2866802 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    130 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Installation height
    4000 m
  • Input voltage range
    3x 320 V AC ... 575 V AC
  • Inrush current
    < 15 A
  • Nominal output voltage
    24 V DC ±1 %
  • Selective Fuse Breaking (ISFB)
    215 A (12 ms)
  • POWER BOOST (IBoost)
    45 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
  • Feedback voltage resistance
    max. 35 V DC
  • Typical response time
    < 0.5 s
  • Protection class
    I
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section solid max.
    6 mm²
  • Screw thread
    M3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Standard - Equipment safety
    GS (tested safety)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Comments
    Criterion A
  • UNSPSC 21.0
    39121004
  • Width
    96 mm
  • Depth
    176 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Output power
    960 W
  • Power loss nominal load max.
    63 W
  • Connection method
    Screw connection
  • Conductor cross section AWG min.
    18
  • Stripping length
    10 mm
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • UL approvals
    UL Listed UL 508
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Frequency range
    0.15 MHz ... 80 MHz
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • Surge voltage load (surge)
    EN 61000-4-5
  • ECLASS 10.0.1
    27040701
  • ECLASS 11.0
    27040701
  • ECLASS 5.0
    27049000
  • ECLASS 5.1
    27049000
  • ETIM 3.0
    EC001039
  • UNSPSC 6.01
    30211502
  • UNSPSC 12.01
    39121004
  • UNSPSC 18.0
    39121004
  • Width with alternative assembly
    176 mm
  • Degree of protection
    IP20
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Degree of pollution
    2
  • Discharge current to PE
    < 3.5 mA
  • Nominal power consumption
    1342 VA
  • Protective circuit/component
    Varistor, gas-filled surge arrester
  • Type of protection
    Transient surge protection
  • Connection in series
    yes
  • Residual ripple
    < 40 mVPP (with nominal values)
  • Net weight
    2.5 kg
  • MTBF (IEC 61709, SN 29500)
    > 880000 h (25 °C)
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Conductor cross section flexible max.
    4 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Rail applications
    EN 50121-4
  • Shipbuilding approval
    DNV GL (EMC A), ABS, LR, RINA, NK, BV
  • Contact discharge
    8 kV (Test Level 4)
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 4.0
    27040700
  • ECLASS 6.0
    27049000
  • ETIM 2.0
    EC001039
  • ETIM 6.0
    EC002540
  • ETIM 7.0
    EC002540
  • UNSPSC 11
    39121004
  • UNSPSC 19.0
    39121004
  • Depth with alternative assembly
    99 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Frequency range DC
    0 Hz
  • Mains buffering time
    > 25 ms (400 V AC)
  • Power factor (cos phi)
    0.76
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Protection against overvoltage at the output (OVP)
    < 35 V DC
  • Peak switching voltages nominal load
    < 5 mVPP (at nominal values, 20 MHz)
  • Efficiency
    > 94 % (at 400 V AC and nominal values)
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    10
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV) / Overvoltage category III
  • Electrostatic discharge
    EN 61000-4-2
  • Discharge in air
    15 kV (Test Level 4)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage
    10 V (Test Level 3)
  • Height with alternative assembly
    130 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • AC frequency range
    45 Hz ... 65 Hz
  • Current consumption
    3x 2.1 A (400 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (AC: Characteristics B, C, D, K)
  • Setting range of the output voltage (USet)
    18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
  • Nominal output current (IN)
    40 A (-25 °C ... 60 °C, UOUT = 24 V DC)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Maximum power dissipation in no-load condition
    18 W
  • Operating voltage display
    Green LED
  • Insulation voltage input/output
    4 kV AC (type test)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard - surge resistance
    VDE 0160 (curve W2)
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Electromagnetic HF field
    EN 61000-4-3
  • Test field strength
    10 V/m (Test Level 3)
  • I/O/S
    asymmetrical
  • Criterion A
    Normal operating behavior within the specified limits.
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27040700
  • ECLASS 7.0
    27049002
  • ECLASS 9.0
    27040701
  • ETIM 4.0
    EC000599
  • UNSPSC 7.0901
    39121004
  • UNSPSC 13.2
    39121004
  • UNSPSC 20.0
    39121004

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 5 days!

1-year warranty

$679.29

Stock:

2

Select Qty:

$679.29

$679.29 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo