2903151 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903151 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single-phase, output: 24 V DC/20 A
Phoenix Contact

Part#:2903151

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 13

Apr 26, 2024

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single-phase, output: 24 V DC/20 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903151 Phoenix Contact price in the box on the right side or send a quick quote.

2903151 Product Details

  • ECLASS 9.0
    27040701
  • Width
    68 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Installation height
    ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
  • Nominal power consumption
    534.7 VA
  • Mains buffering time
    typ. 10 ms (120 V AC)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
  • Connection in series
    yes
  • Feedback voltage resistance
    ≤ 35 V DC
  • Net weight
    1.5 kg
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    6 kV (Test Level 4)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • ECLASS 4.1
    27040702
  • ECLASS 6.0
    27049002
  • Depth
    160 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Discharge current to PE
    < 3.5 mA
  • Inrush current
    ≤ 20 A (typical)
  • Protective circuit/component
    Varistor
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Residual ripple
    < 100 mVPP (with nominal values)
  • Output power
    480 W
  • MTBF (IEC 61709, SN 29500)
    > 1800000 h (25 °C)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Push-in connection
  • Conductor cross section AWG min.
    24
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • UL approvals
    UL Listed UL 508
  • Noise emission
    EN 55016
  • Comments
    Criterion A
  • Input
    3 kV (Test Level 3 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Type of protection
    Transient surge protection
  • Nominal output voltage
    24 V DC ±1 %
  • Dynamic Boost (IDyn.Boost)
    30 A (5 s)
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Typical response time
    < 1 s
  • Insulation voltage input/output
    3 kV AC (type test)
  • Efficiency
    typ. 91.4 % (120 V AC)
  • Height
    130 mm
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    2
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Input fuse
    10 A (internal (device protection))
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristics B, C, D, K)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Power loss nominal load max.
    < 44.8 W (120 V AC)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section solid max.
    1.5 mm²
  • Electrostatic discharge
    EN 61000-4-2
  • Discharge in air
    8 kV (Test Level 4)
  • Conducted interference
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27040702
  • ECLASS 5.0
    27049002
  • UNSPSC 13.2
    39121004
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    5.6 A (100 V AC)
  • Power factor (cos phi)
    0.98
  • Nominal output current (IN)
    20 A
  • Maximum power dissipation in no-load condition
    < 2.9 W (120 V AC)
  • Protection class
    I (in closed control cabinet)
  • Conductor cross section flexible max.
    1.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Shipbuilding approval
    DNV GL
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electromagnetic HF field
    EN 61000-4-3
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • ECLASS 10.0.1
    27040701
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 7.0
    27049002
  • UNSPSC 19.0
    39121004
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    8 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Rail applications
    EN 50121-4
  • Conducted noise emission
    EN 55016
  • Frequency range
    0.15 MHz ... 80 MHz
  • Test field strength
    10 V/m (Test Level 3)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 5.1
    27049002
  • ETIM 6.0
    EC002540
  • ETIM 4.0
    EC002540

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 3 days!

1-year warranty

$276.75

2903151

Stock:

13

Select Qty:

$276.75

$276.75 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo