2909576 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2909576 Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A
Phoenix Contact

Part#:2909576

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2909576 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    106 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Dielectric strength maximum
    300 V AC 30 s
  • Input fuse
    3.15 A (slow-blow, internal)
  • Static Boost (IStat.Boost)
    3.125 A (≤ 40 °C)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Residual ripple
    < 40 mVPP (with nominal values)
  • Power loss nominal load max.
    < 5 W (230 V AC)
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • UL approvals
    UL Listed UL 61010-1
  • Conducted noise emission
    EN 55016
  • Contact discharge
    8 kV (Test Level 4)
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-11
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ETIM 7.0
    EC002540
  • UNSPSC 19.0
    39121004
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Nominal power consumption
    71 VA
  • Type of protection
    Transient surge protection
  • Dynamic Boost (IDyn.Boost)
    5 A (≤60 °C (5 s), Input <150 V AC Derating 0.5 %/V)
  • Feedback voltage resistance
    ≤ 35 V DC
  • Output power
    60 W
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    14
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Signal
    2 kV (Test Level 4 - symmetrical)
  • I/O/S
    asymmetrical
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ECLASS 7.0
    27049002
  • UNSPSC 13.2
    39121004
  • Depth
    90 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Inrush current
    typ. 10 A (at 25 °C)
  • Nominal output current (IN)
    2.5 A
  • Derating
    > 60 °C (2.5%/K)
  • Typical response time
    500 ms
  • Assembly instructions
    DIN rail mounting
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    10 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Frequency range
    0.15 MHz ... 80 MHz
  • Fast transients (burst)
    EN 61000-4-4
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Frequency
    60 Hz
  • Power frequency magnetic field
    EN 61000-4-8
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27242213
  • UNSPSC 18.0
    39121004
  • Width
    32 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Mains buffering time
    typ. 54 ms (120 V AC)
  • Protective circuit/component
    Varistor
  • Connection in series
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Efficiency
    typ. 91.9 % (120 V AC)
  • Protection class
    II
  • Conductor cross section solid min.
    0.2 mm²
  • Standard - Safety of transformers
    EN 61558-2-16
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Noise emission
    EN 55016
  • Test field strength
    1000 A/m
  • Comments
    Criterion B
  • Additional text
    Test Level 2
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 10.0.1
    27040701
  • ETIM 6.0
    EC002540
  • UNSPSC 21.0
    39121004
  • Installation distance top/bottom
    30 mm / 30 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Degree of pollution
    2
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    0.85 A (100 V AC)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Nominal output voltage
    24 V DC
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    < 1 W (230 V AC)
  • MTBF (IEC 61709, SN 29500)
    > 1347000 h (25 °C)
  • Net weight
    0.244 kg
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section AWG min.
    24
  • Standard - Safe isolation
    IEC 61558-2-16
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Discharge in air
    8 kV (Test Level 3)
  • Input
    2 kV (symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage
    300 V (1 s)
  • Voltage dip
    0 %
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • Criterion A
    Normal operating behavior within the specified limits.
  • Attenuated oscillating wave
    EN 61000-4-18
  • ECLASS 6.0
    27049000
  • ECLASS 9.0
    27040701
  • UNSPSC 20.0
    39121004

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo