Welcome to Quotebeam
Nikki Gonzales
Bryan Obida
Nick Goetz

Live support:

Monday - Friday 6AM - 6PM PST

2866695 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2866695 Primary-switched power supply unit, QUINT POWER, Screw connection, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 48 V DC / 20 A
Phoenix Contact

Part#:2866695

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched power supply unit, QUINT POWER, Screw connection, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 48 V DC / 20 A

About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2866695 Phoenix Contact price in the box on the right side or send a quick quote.

2866695 Product Details

  • Height
    130 mm
  • Depth with alternative assembly
    183 mm
  • Degree of protection
    IP20
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • AC frequency range
    45 Hz ... 65 Hz
  • Input fuse
    20 A (fast blow, internal)
  • Nominal output voltage
    48 V DC ±1 %
  • Nominal output current (IN)
    20 A (-25 °C ... 60 °C, UOUT = 48 V DC)
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Efficiency
    > 93 % (for 230 V AC and nominal values)
  • Connection method
    Screw connection
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • SIQ
    BG (type approved)
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    10 V/m (Test Level 3)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Conducted interference
    EN 61000-4-6
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.0
    27242200
  • ETIM 4.0
    EC002540
  • ETIM 7.0
    EC002540
  • UNSPSC 12.01
    39121004
  • UNSPSC 18.0
    39121004
  • Depth
    125 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    2
  • Dielectric strength maximum
    300 V AC
  • Frequency range DC
    0 Hz
  • Nominal power consumption
    1046 VA
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
  • Connection in series
    yes
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Power loss nominal load max.
    74 W
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    10
  • Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
    EN 50178
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electromagnetic HF field
    EN 61000-4-3
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • ECLASS 4.1
    27040700
  • ECLASS 6.0
    27049000
  • ECLASS 9.0
    27040701
  • UNSPSC 13.2
    39121004
  • Width with alternative assembly
    122 mm
  • Width
    180 mm
  • Height with alternative assembly
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Installation height
    6000 m
  • Current consumption
    8.7 A (120 V AC)
  • Inrush current
    < 15 A (typical)
  • Recommended breaker for input protection
    6 A ... 16 A (AC: Characteristics B, C, D, K)
  • POWER BOOST (IBoost)
    22.5 A (-25 °C ... 40 °C permanent, UOUT = 48 V DC )
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Active current limitation
    Approx. IBOOST = 22.5 A (for short-circuit)
  • Protection against overvoltage at the output (OVP)
    < 60 V DC
  • Typical response time
    < 0.65 s
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible max.
    4 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Rail applications
    EN 50121-4
  • Shipbuilding approval
    DNV GL (EMC A)
  • Discharge in air
    15 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 7.0
    27049002
  • UNSPSC 11
    39121004
  • UNSPSC 21.0
    39121004
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    85 V AC ... 264 V AC
  • Discharge current to PE
    < 3.5 mA
  • Mains buffering time
    typ. 20 ms (120 V AC)
  • Protective circuit/component
    Varistor
  • Selective Fuse Breaking (ISFB)
    100 A (12 ms)
  • Feedback voltage resistance
    max. 60 V DC
  • Maximum power dissipation in no-load condition
    12 W
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid max.
    6 mm²
  • Stripping length
    10 mm
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard - Equipment safety
    BG (design tested)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Comments
    Criterion A
  • Input
    2 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • ECLASS 4.0
    27040700
  • ECLASS 5.1
    27242200
  • UNSPSC 6.01
    30211502
  • UNSPSC 20.0
    39121004
  • Output power
    960 W
  • Net weight
    3.3 kg
  • MTBF (IEC 61709, SN 29500)
    > 880000 h (25 °C)
  • Protection class
    I
  • Conductor cross section solid min.
    0.2 mm²
  • Screw thread
    M3
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • UL approvals
    UL Listed UL 508
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27040701
  • ETIM 3.0
    EC001039
  • ETIM 6.0
    EC002540
  • UNSPSC 7.0901
    39121004
  • UNSPSC 19.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo