Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

X20SRT402 B&R Electronic Components

B&R X20SRT402 X20 safe digital mixed module, reACTION Technology for safety, 150 µs safety cycle time, 4 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs
B&R

Part#:X20SRT402

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X20 safe digital mixed module, reACTION Technology for safety, 150 µs safety cycle time, 4 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs

Check out the X20SRT402 B&R price in the box on the right side or send a quick quote.

Product Details

  • Temperature Operation Vertical mounting orientation
    0 to 50°C
  • Temperature Operation Horizontal mounting orientation
    0 to 60°C
  • Safe digital outputs EN ISO 13849-1:2015 PL
    PL d if parameter "Disable OSSD = Yes - Warning", ; PL e if parameter "Disable OSSD = No"
  • Safe digital outputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL
    SIL 2 if parameter "Disable OSSD = Yes - Warning", ; SIL 3 if parameter "Disable OSSD = No"
  • Safe digital outputs EN ISO 13849-1:2015 DC
    >60% if parameter "Disable OSSD = Yes - Warning", ; >94% if parameter "Disable OSSD = No"
  • Safe digital outputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF
    >60% if parameter "Disable OSSD = Yes - Warning", ; >90% if parameter "Disable OSSD = No"
  • Safe digital inputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL
    SIL 3
  • Safe digital inputs EN ISO 13849-1:2015 DC
    >94%
  • Safe digital inputs EN ISO 13849-1:2015 PL
    PL e
  • Safe digital outputs EN ISO 13849-1:2015 Category
    Cat. 3 if parameter "Disable OSSD = Yes - Warning", ; Cat. 4 if parameter "Disable OSSD = No"
  • Safe digital inputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF
    >90%
  • Safe digital inputs EN ISO 13849-1:2015 Category
    Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel
    <1*10-10
  • Relative humidity Storage
    5 to 95%, non-condensing
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless
    <1*10-14 * Number of openSAFETY packets per hour
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Derating
    See section "Derating".
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Temperature Transport
    -40 to 85°C
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired
    Negligible
  • Temperature Storage
    -40 to 85°C
  • Input filter Software
    Configurable between 0 and 500 ms
  • Mounting orientation Vertical
    Yes
  • Switching threshold Low
    <5 VDC
  • Mounting orientation Horizontal
    Yes
  • Switching threshold High
    >15 VDC
  • EN ISO 13849-1:2015 MTTFD
    2500 years
  • EN ISO 13849-1:2015 Mission time
    Max. 20 years
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD
    <2*10-5
  • Input filter Hardware
    ≤130 µs
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT)
    20 years
  • Certifications Functional safety
    cULus FSPC in preparation; ANSI UL 1998 in preparation
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications DNV
    In preparation
  • Certifications UKCA
    Yes
  • Electrical isolation Channel - Channel
    No
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Electrical isolation Channel - Bus
    Yes
  • Certifications CE
    Yes
  • Additional power dissipation caused by actuators (resistive) [W] Safe digital HS-HS outputs
    0.4
  • Blackout mode Function
    Programmable
  • Power consumption Bus
    0.4 W
  • Power consumption Internal I/O
    2.5 W
  • Support reACTION-capable I/O channels
    Yes
  • Blackout mode Standalone mode
    Yes
  • Additional power dissipation caused by actuators (resistive) [W] Pulse outputs
    0.8
  • Blackout mode Scope
    Module
  • Diagnostics Inputs
    Yes, using LED status indicator and software
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • Type of signal lines
    Shielded lines must be used for all signal lines.
  • Diagnostics Outputs
    Yes, using LED status indicator and software
  • System requirements mapp Technology Package
    mapp Safety 5.7.0 or later
  • System requirements Automation Studio
    4.2.5 or later
  • System requirements Safety Release
    1.10 or later
  • System requirements Automation Runtime
    4.2 or later
  • Note
    Order 2x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
  • Pitch
    25+0.2 mm
  • System requirements SafeDESIGNER
    4.2.2 or later
  • Degree of protection per EN 60529
    IP20
  • Installation elevation above sea level
    0 to 2000 m, no limitation
  • Short-circuit current
    15 mAeff
  • Integrated protection
    Reverse polarity protection
  • Test pulse length
    Max. 10 µs
  • IGND
    <200 mA
  • IOUT
    <100 µA
  • Quantity
    4
  • Max. capacitive load
    100 nF
  • Max. switching frequency
    See section "Inrush current behavior for output channels".
  • Switching voltage
    I/O power supply minus voltage drop due to RDS(on)
  • Voltage range
    24 VDC -15% / +20%
  • Leakage current when the output is switched off
    <100 µA
  • RDS(on)
    5 Ω
  • Output protection
    See section "Inrush current behavior for output channels".
  • B&R ID code
    0xE7EC
  • Line length between signal source (pulse output or external signal) and input
    Max. 60 m with unshielded line; Max. 400 m with shielded line
  • Peak short-circuit current
    See section "Inrush current behavior for output channels".
  • Braking voltage when switching off inductive loads
    Max. 45 VDC
  • Status indicators
    I/O function per channel, operating state, module status
  • Total nominal current
    0.4 A
  • I/O module
    4 safe type A digital inputs, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs, reACTION Technology
  • Max. I/O cycle time
    800 µs
  • Nominal output current
    0.2 A
  • Nominal voltage
    24 VDC
  • Input characteristics per EN 61131-2
    Type 1
  • Input resistance
    Min. 7.33 kΩ
  • Insulation voltage between channel and bus
    500 Veff
  • Error detection time
    100 ms
  • Input current at 24 VDC
    Min. 2 mA to max. 3.28 mA
  • Input voltage
    24 VDC -15% / +20%
  • Input circuit
    Sink
  • Variant
    Type A

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo