X20SRT402 B&R Electronic Components
Part#:X20SRT402
Manufacturer:B&R
Product Lifecycle:Active
Get a quick Quote!
X20 safe digital mixed module, reACTION Technology for safety, 150 µs safety cycle time, 4 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs
Check out the X20SRT402 B&R price in the box on the right side or send a quick quote.
Product Details
- Temperature Operation Vertical mounting orientation 0 to 50°C
- Temperature Operation Horizontal mounting orientation 0 to 60°C
- Safe digital outputs EN ISO 13849-1:2015 PL PL d if parameter "Disable OSSD = Yes - Warning", ; PL e if parameter "Disable OSSD = No"
- Safe digital outputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 2 if parameter "Disable OSSD = Yes - Warning", ; SIL 3 if parameter "Disable OSSD = No"
- Safe digital outputs EN ISO 13849-1:2015 DC >60% if parameter "Disable OSSD = Yes - Warning", ; >94% if parameter "Disable OSSD = No"
- Safe digital outputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >60% if parameter "Disable OSSD = Yes - Warning", ; >90% if parameter "Disable OSSD = No"
- Safe digital inputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 3
- Safe digital inputs EN ISO 13849-1:2015 DC >94%
- Safe digital inputs EN ISO 13849-1:2015 PL PL e
- Safe digital outputs EN ISO 13849-1:2015 Category Cat. 3 if parameter "Disable OSSD = Yes - Warning", ; Cat. 4 if parameter "Disable OSSD = No"
- Safe digital inputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >90%
- Safe digital inputs EN ISO 13849-1:2015 Category Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel <1*10-10
- Relative humidity Storage 5 to 95%, non-condensing
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
- Relative humidity Operation 5 to 95%, non-condensing
- Temperature Derating See section "Derating".
- Relative humidity Transport 5 to 95%, non-condensing
- Temperature Transport -40 to 85°C
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired Negligible
- Temperature Storage -40 to 85°C
- Input filter Software Configurable between 0 and 500 ms
- Mounting orientation Vertical Yes
- Switching threshold Low <5 VDC
- Mounting orientation Horizontal Yes
- Switching threshold High >15 VDC
- EN ISO 13849-1:2015 MTTFD 2500 years
- EN ISO 13849-1:2015 Mission time Max. 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD <2*10-5
- Input filter Hardware ≤130 µs
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT) 20 years
- Certifications Functional safety cULus FSPC in preparation; ANSI UL 1998 in preparation
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Certifications DNV In preparation
- Certifications UKCA Yes
- Electrical isolation Channel - Channel No
- Certifications UL cULus E115267; Industrial control equipment
- Electrical isolation Channel - Bus Yes
- Certifications CE Yes
- Additional power dissipation caused by actuators (resistive) [W] Safe digital HS-HS outputs 0.4
- Blackout mode Function Programmable
- Power consumption Bus 0.4 W
- Power consumption Internal I/O 2.5 W
- Support reACTION-capable I/O channels Yes
- Blackout mode Standalone mode Yes
- Additional power dissipation caused by actuators (resistive) [W] Pulse outputs 0.8
- Blackout mode Scope Module
- Diagnostics Inputs Yes, using LED status indicator and software
- Diagnostics Module run/error Yes, using LED status indicator and software
- Type of signal lines Shielded lines must be used for all signal lines.
- Diagnostics Outputs Yes, using LED status indicator and software
- System requirements mapp Technology Package mapp Safety 5.7.0 or later
- System requirements Automation Studio 4.2.5 or later
- System requirements Safety Release 1.10 or later
- System requirements Automation Runtime 4.2 or later
- Note Order 2x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
- Pitch 25+0.2 mm
- System requirements SafeDESIGNER 4.2.2 or later
- Degree of protection per EN 60529 IP20
- Installation elevation above sea level 0 to 2000 m, no limitation
- Short-circuit current 15 mAeff
- Integrated protection Reverse polarity protection
- Test pulse length Max. 10 µs
- IGND <200 mA
- IOUT <100 µA
- Quantity 4
- Max. capacitive load 100 nF
- Max. switching frequency See section "Inrush current behavior for output channels".
- Switching voltage I/O power supply minus voltage drop due to RDS(on)
- Voltage range 24 VDC -15% / +20%
- Leakage current when the output is switched off <100 µA
- RDS(on) 5 Ω
- Output protection See section "Inrush current behavior for output channels".
- B&R ID code 0xE7EC
- Line length between signal source (pulse output or external signal) and input Max. 60 m with unshielded line; Max. 400 m with shielded line
- Peak short-circuit current See section "Inrush current behavior for output channels".
- Braking voltage when switching off inductive loads Max. 45 VDC
- Status indicators I/O function per channel, operating state, module status
- Total nominal current 0.4 A
- I/O module 4 safe type A digital inputs, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs, reACTION Technology
- Max. I/O cycle time 800 µs
- Nominal output current 0.2 A
- Nominal voltage 24 VDC
- Input characteristics per EN 61131-2 Type 1
- Input resistance Min. 7.33 kΩ
- Insulation voltage between channel and bus 500 Veff
- Error detection time 100 ms
- Input current at 24 VDC Min. 2 mA to max. 3.28 mA
- Input voltage 24 VDC -15% / +20%
- Input circuit Sink
- Variant Type A
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨