X20 safe digital input module, coated, safety controller, openSAFETY, 10 openSAFETY nodes, 4 SafeMOTION axes, 4 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC
Check out the X20CSLX410 B&R price in the box on the right side or send a quick quote.
Product Details
- Temperature Operation Horizontal mounting orientation -25 to 60°C
- Temperature Operation Vertical mounting orientation -25 to 50°C
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UDINT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction DINT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UINT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction INT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction BOOL 16
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UDINT 4
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction DINT 4
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction INT 8
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction BOOL 96
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UINT 8
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired Negligible
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel <1*10-10
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
- Relative humidity Transport 5 to 95%, non-condensing
- Relative humidity Storage 5 to 95%, non-condensing
- Relative humidity Operation Up to 100%, condensing
- Temperature Transport -40 to 85°C
- Temperature Storage -40 to 85°C
- Temperature Derating See section "Derating".
- Temperature Starting temperature Yes, -40°C
- Mounting orientation Horizontal Yes
- Switching threshold High >15 VDC
- Mounting orientation Vertical Yes
- Switching threshold Low <5 VDC
- Input filter Software Configurable between 0 and 500 ms
- Input filter Hardware ≤150 µs
- Additional SafeDESIGNER limit values Max. number of variable with variable status 128
- Additional SafeDESIGNER limit values Max. number of force variables 8
- Max. resources available for SafeDESIGNER info window entries Marker count 256
- Additional SafeDESIGNER limit values Max. number of function block types 64
- Max. resources available for SafeDESIGNER info window entries Memory for standard output data 64 bytes
- Max. resources available for SafeDESIGNER info window entries Memory for standard input data 64 bytes
- Max. resources available for SafeDESIGNER info window entries Marker memory 5120 bytes (0x1400)
- Max. resources available for SafeDESIGNER info window entries Memory for safe output data 64 bytes
- Max. resources available for SafeDESIGNER info window entries Memory for safe input data 128 bytes, 68 bytes of which are usable for modules
- Max. resources available for SafeDESIGNER info window entries Stack memory 2048 bytes
- Max. resources available for SafeDESIGNER info window entries FB instances 256
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of linked Managing SafeDOMAINs 0
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. total number of data points for each direction 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Use as Managing SafeDOMAIN Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. total data width for each direction 8 bytes
- Support for Safe Commissioning Options UDINT -
- Data exchange between SafeDOMAIN and SafeDOMAIN Use as Connected SafeDOMAIN No
- Support for Safe Commissioning Options UINT -
- Data exchange between CPU and SafeLOGIC controller Max. total data width for each direction 16 bytes
- Support for Safe Commissioning Options INT -
- Support for Safe Commissioning Options DINT -
- Support for Safe Commissioning Options BOOL 64
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT) 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >90%
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD <2*10-5
- EN ISO 13849-1:2015 Mission time Max. 20 years
- EN ISO 13849-1:2015 DC >94%
- EN ISO 13849-1:2015 MTTFD 2500 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 3
- EN ISO 13849-1:2015 PL PL e
- EN ISO 13849-1:2015 Category Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
- Certifications EAC Yes
- Certifications ABS Yes
- Certifications UL cULus E115267; Industrial control equipment
- Certifications DNV Temperature: A (0 - 45°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck)
- Certifications KR Yes
- Certifications HazLoc cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
- Certifications LR ENV1
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Certifications Functional safety cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
- Certifications CE Yes
- Electrical isolation Channel - Bus Yes
- Power consumption Bus 0.32 W
- Certifications UKCA Yes
- Diagnostics Inputs Yes, using LED status indicator and software
- Electrical isolation Channel - Channel No
- Diagnostics Module run/error Yes, using LED status indicator and software
- System requirements mapp Technology Package mapp Safety 5.7.0 or later
- System requirements Safety Release 1.7 or later
- System requirements SafeDESIGNER 3.1.0 or later
- Switching voltage I/O power supply minus voltage drop due to RDS(on)
- System requirements Automation Runtime From Safety Release 1.7 to 1.9: F4.06 or later; Safety Release 1.10 or later: B4.25 or later
- RDS(on) 60 Ω
- Power consumption Internal I/O 1.25 W
- Leakage current when the output is switched off 0.1 mA
- Installation elevation above sea level 0 to 2000 m, no limitation
- System requirements Automation Studio 4.0.16 or later
- Total nominal current 200 mA
- Note Order 1x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
- Pitch 25+0.2 mm
- Degree of protection per EN 60529 IP20
- Short-circuit current 100 mAeff
- Line length between signal source (pulse output or external signal) and input Max. 60 m with unshielded line; Max. 400 m with shielded line
- Output protection Shutdown of individual channels in the event of overload or short circuit
- Nominal output current 50 mA
- Peak short-circuit current 25 A for 15 µs
- Insulation voltage between channel and bus 500 Veff
- Input voltage 24 VDC -15% / +20%
- Error detection time 200 ms
- Integrated protection Reverse polarity protection
- Input resistance Min. 7.33 kΩ
- Input current at 24 VDC Min. 2 mA to max. 3.28 mA
- Input circuit Sink
- Input characteristics per EN 61131-2 Type 1
- Voltage range 24 VDC -15% / +20%
- Variant Type A
- Max. number of SafeMOTION axes 4, depends on the data width of the modules used
- Nominal voltage 24 VDC
- Quantity 4
- Shortest task class cycle time 2 ms
- Max. number of SafeNODEs 10, depends on the data width of the modules used
- Additional power dissipation caused by actuators (resistive) [W] 0.6
- Status indicators I/O function per channel, operating state, module status
- I/O module 4 safe type A digital inputs, 4 pulse outputs, 24 VDC, SafeLOGIC-X technology
- Max. I/O cycle time 1600 µs
- B&R ID code 0xE288
- Communication with each other Communication only possible with SafeLOGIC controller X20(c)SL81xx; Max. 1 active SafeLOGIC-X controller per standard CPU (e.g. X20(c)CPxxxx)
- Timing precision Time * 0.05 + Cycle time of the safety application
- SafeMOTION support Yes
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨