Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

X20CSLX402 B&R Electronic Components

B&R X20CSLX402 X20 safe digital mixed module, coated, safety controller, openSAFETY, 10 openSAFETY nodes, 4 SafeMOTION axes, 4 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs
B&R

Part#:X20CSLX402

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X20 safe digital mixed module, coated, safety controller, openSAFETY, 10 openSAFETY nodes, 4 SafeMOTION axes, 4 safe type A digital inputs, configurable input filter, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs

Check out the X20CSLX402 B&R price in the box on the right side or send a quick quote.

Product Details

  • Temperature Operation Vertical mounting orientation
    -25 to 50°C
  • Temperature Operation Horizontal mounting orientation
    -25 to 60°C
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UDINT
    2
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction DINT
    2
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction INT
    2
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UINT
    2
  • Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UDINT
    4
  • Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction DINT
    4
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction BOOL
    16
  • Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UINT
    8
  • Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction BOOL
    96
  • Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction INT
    8
  • Safe digital outputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF
    >60% if parameter "Disable OSSD = Yes - Warning", ; >90% if parameter "Disable OSSD = No"
  • Safe digital inputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF
    >90%
  • Safe digital inputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL
    SIL 3
  • Safe digital outputs IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL
    SIL 2 if parameter "Disable OSSD = Yes - Warning", ; SIL 3 if parameter "Disable OSSD = No"
  • Safe digital outputs EN ISO 13849-1:2015 DC
    >60% if parameter "Disable OSSD = Yes - Warning", ; >94% if parameter "Disable OSSD = No"
  • Safe digital outputs EN ISO 13849-1:2015 PL
    PL d if parameter "Disable OSSD = Yes - Warning", ; PL e if parameter "Disable OSSD = No"
  • Safe digital outputs EN ISO 13849-1:2015 Category
    Cat. 3 if parameter "Disable OSSD = Yes - Warning", ; Cat. 4 if parameter "Disable OSSD = No"
  • Safe digital inputs EN ISO 13849-1:2015 DC
    >94%
  • Safe digital inputs EN ISO 13849-1:2015 Category
    Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless
    <1*10-14 * Number of openSAFETY packets per hour
  • Safe digital inputs EN ISO 13849-1:2015 PL
    PL e
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired
    Negligible
  • Relative humidity Transport
    5 to 95%, non-condensing
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel
    <1*10-10
  • Relative humidity Operation
    Up to 100%, condensing
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Temperature Transport
    -40 to 85°C
  • Temperature Storage
    -40 to 85°C
  • Temperature Starting temperature
    Yes, -40°C
  • Mounting orientation Vertical
    Yes
  • Temperature Derating
    See section "Derating".
  • Mounting orientation Horizontal
    Yes
  • Switching threshold High
    >15 VDC
  • Switching threshold Low
    <5 VDC
  • Input filter Software
    Configurable between 0 and 500 ms
  • Additional SafeDESIGNER limit values Max. number of variable with variable status
    128
  • Additional SafeDESIGNER limit values Max. number of force variables
    8
  • Max. resources available for SafeDESIGNER info window entries Marker count
    256
  • Max. resources available for SafeDESIGNER info window entries Memory for safe input data
    128 bytes, 68 bytes of which are usable for modules
  • Max. resources available for SafeDESIGNER info window entries Memory for standard output data
    64 bytes
  • Additional SafeDESIGNER limit values Max. number of function block types
    64
  • Input filter Hardware
    ≤150 µs
  • Max. resources available for SafeDESIGNER info window entries Memory for standard input data
    64 bytes
  • Max. resources available for SafeDESIGNER info window entries Stack memory
    4096 bytes
  • Max. resources available for SafeDESIGNER info window entries Memory for safe output data
    64 bytes
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of linked Managing SafeDOMAINs
    0,; starting with mapp Safety 5.13.0, hardware upgrade 2.4.0.0 and Automation Runtime A4.90: 1
  • Max. resources available for SafeDESIGNER info window entries FB instances
    256
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. total number of data points for each direction
    4
  • Max. resources available for SafeDESIGNER info window entries Marker memory
    5120 bytes (0x1400)
  • Data exchange between SafeDOMAIN and SafeDOMAIN Max. total data width for each direction
    8 bytes
  • Data exchange between SafeDOMAIN and SafeDOMAIN Use as Connected SafeDOMAIN
    Yes, starting with mapp Safety 5.13.0, hardware upgrade 2.4.0.0 and Automation Runtime A4.90
  • Data exchange between CPU and SafeLOGIC controller Max. total data width for each direction
    16 bytes
  • Support for Safe Commissioning Options DINT
    16
  • Data exchange between SafeDOMAIN and SafeDOMAIN Use as Managing SafeDOMAIN
    Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
  • Support for Safe Commissioning Options UDINT
    16
  • Support for Safe Commissioning Options BOOL
    64
  • Support for Safe Commissioning Options UINT
    16
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT)
    20 years
  • Support for Safe Commissioning Options INT
    16
  • IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD
    <2*10-5
  • EN ISO 13849-1:2015 MTTFD
    2500 years
  • EN ISO 13849-1:2015 Mission time
    Max. 20 years
  • Certifications DNV
    In preparation
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications EAC
    Yes
  • Certifications UKCA
    Yes
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications Functional safety
    cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
  • Certifications CE
    Yes
  • Electrical isolation Channel - Channel
    No
  • Additional power dissipation caused by actuators (resistive) [W] Pulse outputs
    0.8
  • Electrical isolation Channel - Bus
    Yes
  • Power consumption Internal I/O
    2.5 W
  • Additional power dissipation caused by actuators (resistive) [W] Safe digital HS-HS outputs
    0.4
  • Blackout mode Standalone mode
    Yes
  • Diagnostics Inputs
    Yes, using LED status indicator and software
  • Power consumption Bus
    0.4 W
  • Blackout mode Function
    Programmable
  • System requirements SafeDESIGNER
    4.2.1 or later
  • Blackout mode Scope
    Module
  • System requirements mapp Technology Package
    mapp Safety 5.7.0 or later
  • Diagnostics Outputs
    Yes, using LED status indicator and software
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • System requirements Safety Release
    1.10 or later
  • System requirements Automation Studio
    4.2 or later
  • System requirements Automation Runtime
    B4.25 or later
  • Pitch
    25+0.2 mm
  • Note
    Order 2x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
  • Installation elevation above sea level
    0 to 2000 m, no limitation
  • IOUT
    <100 µA
  • Degree of protection per EN 60529
    IP20
  • Max. capacitive load
    100 nF
  • IGND
    <200 mA
  • Short-circuit current
    15 mAeff
  • Max. switching frequency
    See section "Inrush current behavior for output channels".
  • RDS(on)
    5 Ω
  • Switching voltage
    I/O power supply minus voltage drop due to RDS(on)
  • Test pulse length
    Max. 10 µs
  • Peak short-circuit current
    See section "Inrush current behavior for output channels".
  • Output protection
    See section "Inrush current behavior for output channels".
  • Braking voltage when switching off inductive loads
    Max. 45 VDC
  • Total nominal current
    0.4 A
  • Leakage current when the output is switched off
    <100 µA
  • Nominal output current
    0.2 A
  • Line length between signal source (pulse output or external signal) and input
    Max. 60 m with unshielded line; Max. 400 m with shielded line
  • Insulation voltage between channel and bus
    500 Veff
  • Error detection time
    100 ms
  • Input voltage
    24 VDC -15% / +20%
  • Quantity
    4
  • Input resistance
    Min. 7.33 kΩ
  • Input circuit
    Sink
  • Input characteristics per EN 61131-2
    Type 1
  • Input current at 24 VDC
    Min. 2 mA to max. 3.28 mA
  • Nominal voltage
    24 VDC
  • Variant
    Type A
  • Voltage range
    24 VDC -15% / +20%
  • Integrated protection
    Reverse polarity protection
  • Max. I/O cycle time
    1 ms
  • Status indicators
    I/O function per channel, operating state, module status
  • Communication with each other
    Communication only possible with SafeLOGIC controller X20(c)SL81xx; Max. 1 active SafeLOGIC-X controller per standard CPU (e.g. X20(c)CPxxxx)
  • SafeMOTION support
    Yes
  • Max. number of SafeMOTION axes
    6, depends on the data width of the modules used
  • I/O module
    4 safe type A digital inputs, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs, SafeLOGIC-X technology
  • Timing precision
    Time * 0.05 + Cycle time of the safety application
  • Max. number of SafeNODEs
    10, depends on the data width of the modules used
  • B&R ID code
    0xF210

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo