X20CSO6300 B&R Electronic Components
Part#:X20CSO6300
Manufacturer:B&R
Product Lifecycle:Active
Get a quick Quote!
X20 safe digital output module, coated, 6 safe type B1 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs
Check out the X20CSO6300 B&R price in the box on the right side or send a quick quote.
Product Details
- Temperature Operation Horizontal mounting orientation -25 to 60°C
- Relative humidity Storage 5 to 95%, non-condensing
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired Negligible
- Temperature Operation Vertical mounting orientation -25 to 50°C
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel <1*10-10
- Relative humidity Transport 5 to 95%, non-condensing
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
- Relative humidity Operation Up to 100%, condensing
- Temperature Derating See section "Derating".
- Temperature Storage -40 to 85°C
- Temperature Transport -40 to 85°C
- Mounting orientation Vertical Yes
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >60% if parameter "Disable OSSD = Yes - Warning", ; >90% if parameter "Disable OSSD = No"
- Mounting orientation Horizontal Yes
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT) 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD <2*10-5
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 2 if parameter "Disable OSSD = Yes - Warning", ; SIL 3 if parameter "Disable OSSD = No"
- EN ISO 13849-1:2015 DC >60% if parameter "Disable OSSD = Yes - Warning", ; >94% if parameter "Disable OSSD = No"
- EN ISO 13849-1:2015 PL PL d if parameter "Disable OSSD = Yes - Warning", ; PL e if parameter "Disable OSSD = No"
- EN ISO 13849-1:2015 MTTFD 2500 years
- EN ISO 13849-1:2015 Mission time Max. 20 years
- Certifications HazLoc cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
- Certifications Functional safety cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
- Certifications DNV In preparation
- Certifications UL cULus E115267; Industrial control equipment
- EN ISO 13849-1:2015 Category Cat. 3 if parameter "Disable OSSD = Yes - Warning", ; Cat. 4 if parameter "Disable OSSD = No"
- Certifications EAC Yes
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Power consumption Internal I/O 1.4 W
- Power consumption Bus 0.32 W
- Blackout mode Function Module functionality
- Certifications UKCA Yes
- Certifications CE Yes
- Electrical isolation Channel - Channel No
- System requirements Safety Release 1.7 or later
- Blackout mode Standalone mode No
- Diagnostics Outputs Yes, using LED status indicator and software
- Electrical isolation Channel - Bus Yes
- Blackout mode Scope Module
- System requirements Automation Runtime V3.08 or later
- System requirements SafeDESIGNER 3.1.0 or later
- Pitch 25+0.2 mm
- Note Order 1x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
- Diagnostics Module run/error Yes, using LED status indicator and software
- System requirements mapp Technology Package mapp Safety 5.7.0 or later
- System requirements Automation Studio 4.0.16 or later
- Max. switching frequency See section "Inrush current behavior for output channels".
- Degree of protection per EN 60529 IP20
- IOUT <100 µA
- Max. capacitive load 100 nF
- Switching voltage I/O power supply minus voltage drop due to RDS(on)
- Braking voltage when switching off inductive loads Max. 45 VDC
- Installation elevation above sea level 0 to 2000 m, no limitation
- RDS(on) 4.7 Ω
- IGND <70 mA
- Test pulse length Max. 10 µs
- Output protection See section "Inrush current behavior for output channels".
- Leakage current when the output is switched off <100 µA
- Insulation voltage between channel and bus 500 Veff
- Error detection time 1 s
- Total nominal current 1.2 A
- Max. I/O cycle time 1 ms
- Nominal output current 0.2 A
- Variant FET, 2x positive switching, type B1, output level readable
- Peak short-circuit current See section "Inrush current behavior for output channels".
- Voltage range 24 VDC -15% / +20%
- Quantity 6
- B&R ID code 0xDD88
- Status indicators I/O function per channel, operating state, module status
- Nominal voltage 24 VDC
- I/O module 6 safe type B1 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs
- Integrated protection Reverse polarity protection
- Additional power dissipation caused by actuators (resistive) [W] 1.128
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.