X20 safe digital input module, safety controller, openSAFETY, 10 openSAFETY nodes, 4 SafeMOTION axes, 2 safe type A digital inputs, configurable input filter, 2 pulse outputs, 24 VDC
Check out the X20SLX210 B&R price in the box on the right side or send a quick quote.
Product Details
- Temperature Operation Horizontal mounting orientation 0 to 60°C
- Temperature Operation Vertical mounting orientation 0 to 50°C
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UDINT 2
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UDINT 4
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction INT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction DINT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction UINT 2
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of data points for each direction BOOL 16
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction DINT 4
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction INT 8
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction UINT 8
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wired Negligible
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
- Data exchange between CPU and SafeLOGIC controller Max. number of data points for each direction BOOL 96
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFH / PFHd Per channel <1*10-10
- Relative humidity Transport 5 to 95%, non-condensing
- Relative humidity Storage 5 to 95%, non-condensing
- Relative humidity Operation 5 to 95%, non-condensing
- Mounting orientation Vertical Yes
- Temperature Transport -40 to 85°C
- Temperature Derating See section "Derating".
- Mounting orientation Horizontal Yes
- Temperature Storage -40 to 85°C
- Switching threshold High >15 VDC
- Input filter Software Configurable between 0 and 500 ms
- Switching threshold Low <5 VDC
- Input filter Hardware ≤150 µs
- Additional SafeDESIGNER limit values Max. number of force variables 8
- Additional SafeDESIGNER limit values Max. number of variable with variable status 128
- Max. resources available for SafeDESIGNER info window entries Marker count 256
- Max. resources available for SafeDESIGNER info window entries Memory for safe output data 64 bytes
- Max. resources available for SafeDESIGNER info window entries Memory for standard output data 64 bytes
- Max. resources available for SafeDESIGNER info window entries Marker memory 5120 bytes (0x1400)
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. total number of data points for each direction 2
- Max. resources available for SafeDESIGNER info window entries FB instances 256
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. number of linked Managing SafeDOMAINs 0
- Max. resources available for SafeDESIGNER info window entries Memory for safe input data 128 bytes, 68 bytes of which are usable for modules
- Additional SafeDESIGNER limit values Max. number of function block types 64
- Max. resources available for SafeDESIGNER info window entries Memory for standard input data 64 bytes
- Max. resources available for SafeDESIGNER info window entries Stack memory 2048 bytes
- Data exchange between SafeDOMAIN and SafeDOMAIN Use as Managing SafeDOMAIN Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0
- Data exchange between SafeDOMAIN and SafeDOMAIN Use as Connected SafeDOMAIN No
- Data exchange between SafeDOMAIN and SafeDOMAIN Max. total data width for each direction 8 bytes
- Support for Safe Commissioning Options UDINT -
- Data exchange between CPU and SafeLOGIC controller Max. total data width for each direction 16 bytes
- Support for Safe Commissioning Options INT -
- Support for Safe Commissioning Options UINT -
- Support for Safe Commissioning Options BOOL 64
- Support for Safe Commissioning Options DINT -
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 Proof test interval (PT) 20 years
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 PFD <2*10-5
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SFF >90%
- IEC 61508:2010,; IEC 61511:2004,; EN 62061:2013 SIL CL SIL 3
- EN ISO 13849-1:2015 Mission time Max. 20 years
- EN ISO 13849-1:2015 MTTFD 2500 years
- EN ISO 13849-1:2015 DC >94%
- EN ISO 13849-1:2015 Category Cat. 3 when using individual input channels, ; Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
- EN ISO 13849-1:2015 PL PL e
- Certifications KC Yes
- Certifications KR Yes
- Certifications EAC Yes
- Certifications LR ENV1
- Certifications ABS Yes
- Certifications DNV Temperature: A (0 - 45°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck)
- Certifications ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
- Certifications UKCA Yes
- Certifications HazLoc cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
- Certifications CE Yes
- Certifications UL cULus E115267; Industrial control equipment
- Electrical isolation Channel - Channel No
- Certifications Functional safety cULus FSPC E361559; Energy and industrial systems; Certified for functional safety; ANSI UL 1998:2013
- Power consumption Bus 0.25 W
- Electrical isolation Channel - Bus Yes
- Power consumption Internal I/O 1 W
- Diagnostics Inputs Yes, using LED status indicator and software
- Diagnostics Module run/error Yes, using LED status indicator and software
- System requirements Safety Release 1.7 or later
- System requirements mapp Technology Package mapp Safety 5.7.0 or later
- System requirements Automation Runtime From Safety Release 1.7 to 1.9: F4.06 or later; Safety Release 1.10 or later: B4.25 or later
- System requirements Automation Studio 4.0.16 or later
- System requirements SafeDESIGNER 3.1.0 or later
- Pitch 25+0.2 mm
- Note Order 1x safety-keyed terminal block separately.; Order 1x safety-keyed bus module separately.
- Degree of protection per EN 60529 IP20
- Switching voltage I/O power supply minus voltage drop due to RDS(on)
- RDS(on) 60 Ω
- Total nominal current 100 mA
- Short-circuit current 100 mAeff
- Installation elevation above sea level 0 to 2000 m, no limitation
- Leakage current when the output is switched off 0.1 mA
- Peak short-circuit current 25 A for 15 µs
- Nominal output current 50 mA
- Line length between signal source (pulse output or external signal) and input Max. 60 m with unshielded line; Max. 400 m with shielded line
- Input resistance Min. 7.33 kΩ
- Output protection Shutdown of individual channels in the event of overload or short circuit
- Insulation voltage between channel and bus 500 Veff
- Input characteristics per EN 61131-2 Type 1
- Error detection time 200 ms
- Input current at 24 VDC Min. 2 mA to max. 3.28 mA
- Input circuit Sink
- Voltage range 24 VDC -15% / +20%
- Variant Type A
- Integrated protection Reverse polarity protection
- Quantity 2
- Input voltage 24 VDC -15% / +20%
- Nominal voltage 24 VDC
- Max. number of SafeNODEs 10, depends on the data width of the modules used
- SafeMOTION support Yes
- Shortest task class cycle time 2 ms
- I/O module 2 safe type A digital inputs, 2 pulse outputs, 24 VDC, SafeLOGIC-X technology
- Status indicators I/O function per channel, operating state, module status
- B&R ID code 0xC5B0
- Additional power dissipation caused by actuators (resistive) [W] 0.3
- Max. I/O cycle time 1600 µs
- Communication with each other Communication only possible with SafeLOGIC controller X20(c)SL81xx; Max. 1 active SafeLOGIC-X controller per standard CPU (e.g. X20(c)CPxxxx)
- Timing precision Time * 0.05 + Cycle time of the safety application
- Max. number of SafeMOTION axes 4, depends on the data width of the modules used
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨