3273646 Phoenix Contact Terminal Blocks

Phoenix Contact 3273646 Distribution block, connection method: Push-in connection, Push-in connection, number of connections: 19, cross section: 0.5 mm² - 10 mm², AWG: 20 - 6, width: 28.6 mm, color: brown, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3273646

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 6

Nov 19, 2024

Distribution block, connection method: Push-in connection, Push-in connection, number of connections: 19, cross section: 0.5 mm² - 10 mm², AWG: 20 - 6, width: 28.6 mm, color: brown, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273646 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Potentials
    1
  • Color
    brown
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    63 A
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    28.6 mm
  • Connection
    Feed-in stage
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG max.
    10
  • Connection cross sections directly pluggable
    0.5 mm² 6 mm² 20 10
  • Internal cylindrical gage
    A4
  • ECLASS 4.1
    27141121
  • ECLASS 9.0
    27141120
  • UNSPSC 6.01
    30211811
  • UNSPSC 21.0
    39121410
  • Nominal cross section feed-in
    10 mm²
  • Degree of pollution
    3
  • Maximum total current
    63 A
  • Result of surge voltage test
    Test passed
  • Tensile test result
    Test passed
  • Result of voltage-drop test
    Test passed
  • Conductor cross section short circuit testing
    10 mm²
  • Result of aging test
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.0
    27141120
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 18.0
    39121410
  • Number of levels
    1
  • Nominal cross section
    4 mm²
  • Rated surge voltage
    6 kV
  • Insulating material group
    I
  • Value
    0.75 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 7.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Number of connections
    19
  • Insulating material
    PA
  • Overvoltage category
    III
  • Open side panel
    No
  • Power frequency withstand voltage setpoint
    2 kV
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 10.0.1
    27141120
  • ETIM 3.0
    EC000897
  • ETIM 6.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 20.0
    39121410
  • Nominal voltage UN
    800 V
  • Finger protection
    guaranteed
  • Back of the hand protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Tight fit on carrier
    NS 35
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Acceleration
    30g
  • Shock duration
    18 ms
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Conductor cross section solid min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.0
    27141121
  • ECLASS 5.1
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 19.0
    39121410
  • Short-time current
    1.2 kA
  • Test duration per axis
    5 h
  • Height NS 15
    30.4 mm
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Max. AWG conductor cross section, flexible
    12
  • Result of power-frequency withstand voltage test
    Test passed
  • Short circuit stability result
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Length
    58.1 mm
  • Connection in acc. with standard
    IEC 60998-2-2
  • Min. AWG conductor cross section, flexible
    24
  • Bending test turns
    135
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Setpoint
    5 N
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Shock form
    Half-sine
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Nominal current IN
    32 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Static insulating material application in cold
    -60 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    32.4 mm
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.2 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$12.07

Stock:

6

Select Qty:

$12.07

$12.07 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo