Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3273628 Phoenix Contact Terminal Blocks

Phoenix Contact 3273628 Distribution block, connection method: Push-in connection, Push-in connection, number of connections: 13, cross section: 0.5 mm² - 10 mm², AWG: 20 - 6, width: 28.6 mm, color: black, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3273628

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 27

Nov 21, 2024

Distribution block, connection method: Push-in connection, Push-in connection, number of connections: 13, cross section: 0.5 mm² - 10 mm², AWG: 20 - 6, width: 28.6 mm, color: black, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273628 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of connections
    13
  • Degree of pollution
    3
  • Insulating material group
    I
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of surge voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Tensile test result
    Test passed
  • Conductor cross section short circuit testing
    10 mm²
  • Oscillation, broadband noise test result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock duration
    18 ms
  • Number of levels
    1
  • Color
    black
  • Rated surge voltage
    6 kV
  • Nominal current IN
    32 A
  • Nominal voltage UN
    800 V
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Potentials
    1
  • Nominal cross section feed-in
    10 mm²
  • Overvoltage category
    III
  • Open side panel
    No
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 35
  • Result of temperature-rise test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    58.1 mm
  • Conductor cross section solid min.
    0.5 mm²
  • ETIM 6.0
    EC000897
  • UNSPSC 18.0
    39121410
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    63 A
  • Back of the hand protection
    guaranteed
  • Power frequency withstand voltage setpoint
    2 kV
  • Result of tight fit on support
    Test passed
  • Result of voltage-drop test
    Test passed
  • Short circuit stability result
    Test passed
  • UNSPSC 7.0901
    39121410
  • UNSPSC 11
    39121410
  • Nominal cross section
    4 mm²
  • Insulating material
    PA
  • Maximum total current
    63 A
  • Finger protection
    guaranteed
  • Bending test turns
    135
  • Setpoint
    5 N
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Result of aging test
    Test passed
  • UNSPSC 6.01
    30211811
  • UNSPSC 12.01
    39121410
  • UNSPSC 19.0
    39121410
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short-time current
    1.2 kA
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410
  • Number of shocks per direction
    3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    28.6 mm
  • Height NS 15
    30.4 mm
  • Conductor cross section AWG max.
    10
  • ETIM 4.0
    EC000897
  • ETIM 7.0
    EC000897
  • UNSPSC 20.0
    39121410
  • Test duration per axis
    5 h
  • Shock form
    Half-sine
  • Value
    0.75 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60998-2-2
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141120
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • ASD level
    6.12 (m/s2)2/Hz
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.2 mm²
  • Connection cross sections directly pluggable
    0.5 mm² 6 mm² 20 10
  • Result of thermal test
    Test passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Height NS 35/7,5
    32.4 mm
  • Max. AWG conductor cross section, flexible
    12
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141121
  • ETIM 3.0
    EC000897
  • Acceleration
    30g
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Connection
    Feed-in stage
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.2 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141120
  • ECLASS 6.0
    27141100
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Connection method
    Push-in connection
  • Conductor cross section solid max.
    6 mm²
  • Min. AWG conductor cross section, flexible
    24
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Internal cylindrical gage
    A4
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141120
  • ECLASS 9.0
    27141120
  • ECLASS 10.0.1
    27141120
  • ECLASS 4.1
    27141121
  • ECLASS 7.0
    27141120

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$8.73

Stock:

27

Select Qty:

$8.73

$8.73 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo