3273268 Phoenix Contact Terminal Blocks
Part#:3273268
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Distribution block, Basic terminal block, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 24 A, connection method: Push-in connection, number of
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3273268 Phoenix Contact price in the box on the right side or send a quick quote.
3273268 Product Details
- Color red
- Degree of pollution 3
- Maximum power dissipation for nominal condition 0.77 W (the value is based on one connection block and is multiplied according to the pin assignment)
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Number of shocks per direction 3
- Shock duration 18 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height 21.7 mm
- Conductor cross section AWG max. 12
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Connection cross sections directly pluggable 0.34 mm² 4 mm² 24 12
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 6.0 27141100
- ETIM 7.0 EC000897
- UNSPSC 12.01 39121410
- Number of levels 1
- Nominal cross section 2.5 mm²
- Maximum load current 32 A
- Back of the hand protection guaranteed
- Test spectrum Service life test category 2, bogie-mounted
- Acceleration 30g
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Conductor cross section solid min. 0.34 mm²
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Internal cylindrical gage A3
- ECLASS 11.0 27141120
- ECLASS 5.1 27141120
- ETIM 4.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 21.0 39121410
- Potentials 1
- Overvoltage category III
- Nominal current IN 24 A
- Finger protection guaranteed
- Shock form Half-sine
- Shock test result Test passed
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Connection method Push-in connection
- Conductor cross section solid max. 4 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 10.0.1 27141120
- ECLASS 4.1 27141121
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 20.0 39121410
- UNSPSC 18.0 39121410
- Note Notes on operation The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories
- Rated surge voltage 6 kV
- Maximum total current 48 A
- Nominal voltage UN 450 V
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- ASD level 6.12 (m/s2)2/Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Length 28.6 mm
- Stripping length 8 mm ... 10 mm
- Conductor cross section AWG min. 26
- Min. AWG conductor cross section, flexible 26
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 5.0 27141120
- ECLASS 9.0 27141120
- UNSPSC 11 39121410
- UNSPSC 19.0 39121410
- Number of connections 6
- Open side panel No
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Width 16 mm
- Connection in acc. with standard IEC 60998-2-2
- Conductor cross section flexible min. 0.14 mm²
- Max. AWG conductor cross section, flexible 12
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.0 27141121
- ETIM 3.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 13.2 39121410
- Flammability rating according to UL 94 V0
- Insulating material PA
- Insulating material group I
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
3273268
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨