Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2903147 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903147 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/3 A C2LPS
Phoenix Contact

Part#:2903147

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 41

Apr 24, 2024

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/3 A C2LPS

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903147 Phoenix Contact price in the box on the right side or send a quick quote.

2903147 Product Details

  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Discharge current to PE
    < 0.25 mA
  • Input fuse
    6.3 A (internal (device protection))
  • Nominal output voltage
    24 V DC ±1 %
  • Feedback voltage resistance
    ≤ 35 V DC
  • Output power
    72 W
  • Insulation voltage input/output
    3 kV AC (type test)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section flexible max.
    1.5 mm²
  • Stripping length
    8 mm
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Electrostatic discharge
    EN 61000-4-2
  • Fast transients (burst)
    EN 61000-4-4
  • Criterion A
    Normal operating behavior within the specified limits.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.0
    27049000
  • ETIM 4.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Height
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Mains buffering time
    typ. 10 ms (120 V AC)
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Net weight
    0.35 kg
  • Protection class
    II (in closed control cabinet)
  • Depth
    115 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Nominal power consumption
    157.7 VA
  • Type of protection
    Transient surge protection
  • Nominal output current (IN)
    3 A
  • Width
    30 mm
  • Ambient temperature (start-up type tested)
    -25 °C
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    1.4 A (100 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Dynamic Boost (IDyn.Boost)
    4.5 A (1 s)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Maximum power dissipation in no-load condition
    < 1 W
  • Typical response time
    < 1 s
  • Connection method
    Push-in connection
  • Conductor cross section AWG min.
    24
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Rail applications
    EN 50121-4
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    0.15 MHz ... 80 MHz
  • Conducted interference
    EN 61000-4-6
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 4.1
    27040700
  • ECLASS 7.0
    27049002
  • UNSPSC 13.2
    39121004
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Inrush current
    ≤ 15 A (typical)
  • Power factor (cos phi)
    0.52
  • Connection in series
    yes
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Efficiency
    > 89 % (for 230 V AC and nominal values)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage
    10 V (Test Level 3)
  • ECLASS 5.1
    27049000
  • ETIM 7.0
    EC002540
  • UNSPSC 18.0
    39121004
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Power loss nominal load max.
    < 10 W
  • MTBF (IEC 61709, SN 29500)
    > 3500000 h (25 °C)
  • Conductor cross section solid max.
    1.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Contact discharge
    6 kV (Test Level 4)
  • Test field strength
    10 V/m (Test Level 3)
  • Input
    3 kV (Test Level 3 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27040700
  • ECLASS 6.0
    27049000
  • ETIM 6.0
    EC002540
  • UNSPSC 19.0
    39121004
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Standard - Safe isolation
    DIN VDE 0100-410
  • UL approvals
    UL Listed UL 508
  • Discharge in air
    8 kV (Test Level 4)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • ECLASS 10.0.1
    27040701
  • ECLASS 11.0
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 21.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$99.07

2903147

Stock:

41

Select Qty:

$99.07

$99.07 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo