Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2904607 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904607 Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 7.5 A
Phoenix Contact

Part#:2904607

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 12

Apr 24, 2024

About the product: Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 7.5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904607 Phoenix Contact price in the box on the right side or send a quick quote.

2904607 Product Details

  • Climatic class
    3K3 (in acc. with EN 60721)
  • Current consumption
    1 A (100 V AC)
  • Protective circuit/component
    Varistor
  • Dynamic Boost (IDyn.Boost)
    12.75 A (≤ 60 °C (5 s))
  • Feedback voltage resistance
    ≤ 25 V DC
  • Typical response time
    300 ms
  • Net weight
    0.3 kg
  • Connection method
    Push-in connection
  • Conductor cross section AWG min.
    24
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Noise emission
    EN 55016
  • Contact discharge
    8 kV (Test Level 4)
  • Frequency range
    50 Hz ... 60 Hz
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Frequency
    60 Hz
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Installation distance right/left (active, passive)
    0 mm / 0 mm (POut ≤50 %)
  • Installation distance top/bottom (active, passive)
    30 mm / 30 mm (POut ≤50 %)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Dielectric strength maximum
    300 V AC 60 s
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C or comparable)
  • Nominal output voltage
    12 V DC
  • Connection in series
    yes
  • Maximum power dissipation in no-load condition
    < 0.6 W (230 V AC)
  • Efficiency
    typ. 91.5 % (120 V AC)
  • MTBF (IEC 61709, SN 29500)
    > 1221000 h (25 °C)
  • Stripping length
    10 mm
  • Standard - Safe isolation
    IEC 61558-2-16
  • Conducted noise emission
    EN 55016
  • Discharge in air
    15 kV (Test Level 4)
  • Width
    45 mm
  • Installation distance right/left (passive)
    5 mm / 5 mm (POut ≥50% )
  • Degree of protection
    IP20
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    2
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Input fuse
    3.15 A (slow-blow, internal)
  • Type of protection
    Transient surge protection
  • Protection against overvoltage at the output (OVP)
    ≤ 18 V DC
  • Protection class
    II
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Safety of transformers
    EN 61558-2-16
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Flicker
    EN 61000-3-3
  • Test field strength
    1000 A/m
  • Voltage
    1 kV (symmetrical)
  • Voltage dips
    EN 61000-4-11
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • ECLASS 10.0.1
    27040701
  • ECLASS 7.0
    27049002
  • UNSPSC 21.0
    39121004
  • Depth
    90 mm
  • Installation distance top/bottom (passive)
    30 mm / 30 mm (POut ≥50% )
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Inrush current
    typ. 11.4 A (at 25 °C)
  • Setting range of the output voltage (USet)
    12 V DC ... 15 V DC (constant capacity)
  • Control deviation
    < 0.3 % (Static load change 10 % ... 90 %)
  • Output power
    90 W
  • Power loss nominal load max.
    < 8.1 W (120 V AC)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Comments
    Criterion A
  • Conducted interference
    EN 61000-4-6
  • Additional text
    Test Level 2
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Attenuated oscillating wave
    EN 61000-4-18
  • ECLASS 5.1
    27242213
  • Height
    106 mm
  • Installation distance right/left (active)
    15 mm / 15 mm (POut ≥50% )
  • Installation distance top/bottom (active)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Nominal power consumption
    96.3 VA
  • Mains buffering time
    typ. 48 ms (120 V AC)
  • Nominal output current (IN)
    7.5 A
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Residual ripple
    < 35 mVPP (with nominal values)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    14
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • UL approvals
    UL Listed UL 61010-1
  • Harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    2 kV (symmetrical)
  • Fast transients (burst)
    EN 61000-4-4
  • Power frequency magnetic field
    EN 61000-4-8
  • Voltage dip
    0 %
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 2)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ETIM 6.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Signal
    0.5 kV (Test Level 2 - symmetrical)
  • I/O/S
    asymmetrical
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Test level 1
    16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 9.0
    27040701
  • UNSPSC 18.0
    39121004
  • Criterion A
    Normal operating behavior within the specified limits.
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27049000
  • ETIM 7.0
    EC002540
  • UNSPSC 19.0
    39121004
  • UNSPSC 13.2
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$179.53

2904607

Stock:

12

Select Qty:

$179.53

$179.53 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo