Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2904372 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904372 Primary-switched UNO power supply for DIN rail mounting, input: single-phase, output: 24 V DC/240 W
Phoenix Contact

Part#:2904372

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Primary-switched UNO power supply for DIN rail mounting, input: single-phase, output: 24 V DC/240 W

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904372 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Voltage dips
    EN 61000-4-11
  • Width
    45 mm
  • Depth
    125 mm
  • Installation distance top/bottom
    30 mm / 30 mm
  • Ambient temperature (start-up type tested)
    -25 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Frequency range (fN)
    50 Hz ... 60 Hz 10 %
  • Nominal power consumption
    260 VA
  • Current consumption
    2.69 A (100 V AC)
  • Power factor (cos phi)
    0.99
  • Nominal output current (IN)
    10 A (-25 °C ... 55 °C)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Power loss nominal load max.
    < 18.8 W
  • Nominal output voltage
    24 V DC ±1 %
  • Connection in series
    No
  • Protection against overvoltage at the output (OVP)
    ≤ 35 V DC
  • Maximum power dissipation in no-load condition
    < 1.1 W
  • Protection class
    I (in closed control cabinet)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section AWG max.
    14
  • Standard - Safety of transformers
    EN 61558-2-16
  • Mains variation/undervoltage
    EN 61000-4-11
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    10 V/m (Test Level 3)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Degree of pollution
    2
  • Inrush current
    < 80 A (typical)
  • Mains buffering time
    > 10 ms (120 V AC)
  • Input fuse
    5 A (slow-blow, internal)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC ±1 %
  • Control deviation
    change in load, static 10 % ... 90 %
  • Insulation voltage input/output
    4 kV AC (type test)
  • Assembly instructions
    alignable: 0 mm horizontally, 30 mm vertically
  • Connection method
    Screw connection
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • ECLASS 5.0
    27049000
  • ECLASS 5.1
    27049000
  • UNSPSC 18.0
    39121004
  • Type of protection
    Transient surge protection
  • Feedback voltage resistance
    < 35 V DC
  • Output power
    240 W
  • Efficiency
    typ. 90 % (120 V AC)
  • Housing material
    Aluminum / polycarbonate
  • Conductor cross section flexible max.
    2.5 mm²
  • Screw thread
    M3
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Frequency range
    0.15 MHz ... 80 MHz
  • Conducted interference
    EN 61000-4-6
  • ECLASS 6.0
    27049000
  • ETIM 4.0
    EC000599
  • UNSPSC 19.0
    39121004
  • Height
    130 mm
  • Degree of protection
    IP20
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Input voltage range
    85 V AC ... 264 V AC (< 95 V AC Derating 1 %/V)
  • AC frequency range
    50 Hz ... 60 Hz
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Protective circuit/component
    Varistor
  • Derating
    55 °C ... 70 °C (2.5%/K)
  • Typical response time
    < 1 s
  • Net weight
    0.66 kg
  • MTBF (IEC 61709, SN 29500)
    > 641000 h (40 °C)
  • Conductor cross section flexible min.
    0.2 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Safety extra-low voltage
    IEC 62368-1 (SELV) und EN 60204-1 (PELV)
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Discharge in air
    8 kV (Test Level 3)
  • Fast transients (burst)
    EN 61000-4-4
  • UNSPSC 21.0
    39121004
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 7.0
    27049002
  • UNSPSC 20.0
    39121004
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Stripping length
    8 mm
  • UL approvals
    UL/C-UL listed UL 508
  • Contact discharge
    6 kV (Test Level 3)
  • ECLASS 4.1
    27040700
  • ETIM 6.0
    EC002540
  • Voltage
    10 V (Test Level 3)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • UNSPSC 13.2
    39121004
  • Conductor cross section solid max.
    2.5 mm²
  • Standard - Electrical safety
    IEC 62368-1/VDE 0805 (SELV)
  • ECLASS 4.0
    27040700
  • ECLASS 9.0
    27040701
  • Comments
    Criterion A
  • Surge voltage load (surge)
    EN 61000-4-5
  • ECLASS 11.0
    27040701
  • ETIM 7.0
    EC002540

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo