2903149 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903149 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A
Phoenix Contact

Part#:2903149

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A

About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2903149 Phoenix Contact price in the box on the right side or send a quick quote.

2903149 Product Details

  • Height
    130 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Dielectric strength maximum
    300 V AC 15 s
  • Width
    42 mm
  • Degree of protection
    IP20
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • Discharge current to PE
    < 3.5 mA
  • Nominal power consumption
    285 VA
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Installation distance top/bottom
    50 mm / 50 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (start-up type tested)
    -25 °C
  • Installation height
    ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Current consumption
    3.1 A (100 V AC)
  • Power factor (cos phi)
    0.93
  • Nominal output current (IN)
    10 A
  • Feedback voltage resistance
    ≤ 35 V DC
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Efficiency
    > 91 % (for 230 V AC and nominal values)
  • MTBF (IEC 61709, SN 29500)
    > 1800000 h (25 °C)
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Rail applications
    EN 50121-4
  • Discharge in air
    8 kV (Test Level 4)
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    0.15 MHz ... 80 MHz
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • Surge voltage load (surge)
    EN 61000-4-5
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 4.0
    27040700
  • ECLASS 6.0
    27049000
  • ECLASS 7.0
    27049002
  • ETIM 6.0
    EC002540
  • UNSPSC 18.0
    39121004
  • Depth
    160 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Mains buffering time
    typ. 15 ms (120 V AC)
  • Type of protection
    Transient surge protection
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Connection in series
    yes
  • Residual ripple
    < 10 mVPP (with nominal values)
  • Net weight
    1 kg
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    8 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • UL approvals
    UL Listed UL 508
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electrostatic discharge
    EN 61000-4-2
  • Contact discharge
    6 kV (Test Level 4)
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • Voltage
    10 V (Test Level 3)
  • ECLASS 10.0.1
    27040701
  • ECLASS 4.1
    27040700
  • ECLASS 5.0
    27049000
  • ETIM 4.0
    EC002540
  • UNSPSC 13.2
    39121004
  • UNSPSC 19.0
    39121004
  • UNSPSC 21.0
    39121004
  • Inrush current
    ≤ 25 A (typical)
  • Input fuse
    6.3 A (internal (device protection))
  • Nominal output voltage
    24 V DC ±1 %
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Output power
    240 W
  • Power loss nominal load max.
    < 25 W
  • Maximum power dissipation in no-load condition
    < 5.1 W (230 V)
  • Protection class
    I (in closed control cabinet)
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Test field strength
    10 V/m (Test Level 3)
  • Comments
    Criterion A
  • Input
    3 kV (Test Level 3 - symmetrical)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27040701
  • ECLASS 5.1
    27049000
  • ECLASS 9.0
    27040701
  • ETIM 7.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Typical response time
    < 1 s
  • Insulation voltage input/output
    3 kV AC (type test)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section AWG max.
    16

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!