1162150 Phoenix Contact Electrical Wires & Cables

Phoenix Contact 1162150 CHARX connect, Vehicle charging inlet, Locking actuator right, For charging with alternating current (AC) and with direct current (DC), For installation in electric vehicles (EV), CCS type 2, Combined Charging System, IEC 62196-2, IEC 62196-3, 200 A / 100
Phoenix Contact

Part#:1162150

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1

Apr 24, 2024

About the product: CHARX connect, Vehicle charging inlet, Locking actuator right, For charging with alternating current (AC) and with direct current (DC), For installation in electric vehicles (EV), CCS type 2, Combined Charging System, IEC 62196-2, IEC 62196-3, 200 A / 100

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Wires & Cables that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1162150 Phoenix Contact price in the box on the right side or send a quick quote.

1162150 Product Details

  • Type
    Locking actuator right
  • Charging standard
    CCS type 2
  • Width
    108 mm
  • Max. altitude
    4000 m (above sea level)
  • Number of power contacts
    5 (L1, N, PE, DC+, DC-)
  • Rated current for signal contacts
    2 A
  • Rated voltage for signal contacts
    30 V AC
  • Standards/regulations
    DIN EN 60751
  • Ambient temperature (operation)
    -40 °C ... 80 °C
  • Conductor length
    2 m (AC cables)
  • Rated current of power contacts
    32 A AC
  • Resistor coding
    4.7 kΩ (between PE and PP)
  • Insertion force
    < 100 N
  • Required mounting screws
    M6
  • Housing color
    black
  • External sheath, color
    Green-yellow
  • Outer sheath, material
    PVC
  • Reverse current of the motor
    max. 1.5 A
  • Cable length
    1 m
  • Tolerance at the sensor with the recommended measured current
    ±5K
  • ECLASS 11.0
    27144706
  • Application
    For charging with alternating current (AC) and with direct current (DC)
  • Note
    A protective cap is supplied as standard for the DC and AC contacts.
  • Bore dimensions
    117.65 mm x 90 mm, 117.65 mm x 83 mm
  • Height
    140.25 mm
  • Degree of protection
    IP55 (plugged in; when plugged in and ready to operate, the degree of protection is only ensued if both plug-in components are original products from Phoenix Contact or suitable standard-compliant products)
  • Number of phases
    1
  • Number of signal contacts
    2 (CP, PP)
  • Insulation resistance of neighboring contacts
    > 200 MΩ
  • Temperature monitoring
    AC contacts: PTC chain (DIN˽EN˽60738-1)
  • Withdrawal force
    < 100 N
  • Material
    Plastic
  • Locking type
    Locking in the inserted state with a locking mechanism
  • Cable resistance
    ≤ 37.1 Ω/km
  • Single wire, color
    black PP/CS
  • Number of positions of theconnectors
    4
  • Recommended adaptation time
    600 ms
  • Type of sensor
    Pt 1000
  • Temperature range
    -40 °C ... 130 °C
  • Charging mode
    Mode 2, 3, 4
  • Depth
    128.4 mm
  • Type of charging current
    DC, AC 1-phase
  • Rated voltage for power contacts
    250 V AC
  • Insertion/withdrawal cycles
    > 10000
  • Mounting hole diameter
    6.80 mm (ø)
  • Screws included in the scope of delivery
    none
  • Design line
    Generation 4
  • Material surface of contacts
    Ag
  • Operating voltage
    12 V (Typical power supply at the motor)
  • Max. dwell time with reverse current
    1 s
  • Pause time after entry or exit path
    3 s
  • ECLASS 10.0.1
    27144706
  • Design
    Generation 4
  • Note on the connection method
    Crimp connection, cannot be disconnected
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Maximum charging power
    200 kW
  • Type of signal transmission
    Pulse width modulation with modulated Powerline communication according to ISO/IEC 15118 / DIN SPEC 70121
  • Temperature measurement
    DC contacts: 2x PT1000 (DIN EN 60751)
  • Restrictions to mounting position
    Only 0 to 90 degree frontal inclination possible, see figure
  • Cable structure
    4 x 0.5 mm²
  • Minimum bending radius
    15 mm
  • Possible power supply range at the motor
    9 V ... 16 V
  • Service life insertion cycles
    > 10000 load cycles
  • Recommended measured current
    ≤ 1 mA (Umax= 16 V DC)
  • ECLASS 9.0
    27144706
  • Mounting position of the locking actuator
    Right-side
  • Customer variations
    On request
  • Flammability rating
    V0
  • External cable diameter
    1.6 mm -0.2 mm
  • Cable weight
    7 kg/km
  • Maximum voltage for locking detection
    12 V
  • Typical motor current for locking
    0.25 A
  • Lock recognition
    available
  • Mechanical emergency release
    available
  • Resistance range
    650 Ω ... 1450 Ω

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$660.00

1162150

Stock:

1

Select Qty:

$660.00

$660.00 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo