Electrical Safety Devices
part#
description
manufacturer
1217839
Set of 35 safety relays for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e in accordance with EN ISO 13849, automatic or manual activation, 2 N/O contacts with a dropout delay of 0.1 s to 30 s, plug-in screw connection terminal bloc
Phoenix Contact
Quick Quote
2702924
1 or 2-channel contact extension with wide range input, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, together with basic device up to Cat. 4, PL e according to EN ISO 13849, plug-in screw terminal block, width: 22.5 mm
Phoenix Contact
Quick Quote
2964005
Single-channel or two-channel contact extension, 5 N/O contacts, 1 N/C contact, 1 confirmation current path, together with basic device up to Cat. 4 PL e in accordance with EN ISO 13849 safe isolation, width: 35 mm, pluggable Push-in terminal block
Phoenix Contact
Quick Quote
2904952
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Phoenix Contact
Quick Quote
2700553
Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, non-equivalent operation, automatic or manual, monitored start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block
Phoenix Contact
Quick Quote
2700574
Safety relay for two-hand control devices according to EN 574 type IIIC, up to SILCL 3, Cat. 4, PL e, synchronous activation monitoring < 0.5 s, 2 enabling current paths, US = 24 V DC, plug-in screw terminal block
Phoenix Contact
Quick Quote
1082024
Safety relay for emergency stop, safety doors, and light grids up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block
Phoenix Contact
Quick Quote
2702096
Safety relay for emergency stop, safety doors, light grid up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, fall back/tightening delay 0.2 s to 60 s, 2 enabling current paths, US = 24 V DC, plug-in screw
Phoenix Contact
Quick Quote
1015526
Safety relay for emergency stop, safety doors, light grid up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, fall back/on delay 0.2 s to 300 s, 5 enabling current paths, US = 24 V DC, pluggable Push-in ter
Phoenix Contact
Quick Quote
1539570
Short-circuit plug, for bridging unused slots on PSR-SACB sensor box for safety limit switch
Phoenix Contact
Quick Quote
2981732
1-channel contact extension with TBUS interface, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, the contacts have an off-delay (0.3 … 3 s), Cat. 3, PL e in accordance with EN ISO 13849, plug-in terminal blocks with screw connection, width: 22
Phoenix Contact
Quick Quote
2981648
Cable adapter for PSR over-speed safety relays (PSR-RSM4 and PSR-MM30), 15/8-pos., cable length: 2.5 m, for controller: Indramat
Phoenix Contact
Quick Quote
2981554
Configuration software for parameterizing the PSR-RSM4 safe downtime and over-speed safety relay, with programming cable
Phoenix Contact
Quick Quote
PILZ-C1000042
Pilz PILZ-C1000042
Pilz
Quick Quote
PILZ-C1000040
Pilz PILZ-C1000040
Pilz
Quick Quote
PILZ-C1000033
Pilz PILZ-C1000033
Pilz
Quick Quote
PILZ-C1000029
Pilz PILZ-C1000029
Pilz
Quick Quote
PILZ-C1000027
Pilz PILZ-C1000027
Pilz
Quick Quote
PILZ-C1000020
Pilz PILZ-C1000020
Pilz
Quick Quote
PILZ-C1000015
Pilz PILZ-C1000015
Pilz
Quick Quote
Items per page:
Electrical Safety Devices
General Guide & Overview
Electrical safety devices are crucial in both industrial and residential settings to protect against potential electrical hazards. Incorrect handling of electricity can lead to fires, electrocution, and serious injuries. Fortunately, there are a variety of safety devices available to prevent such dangerous situations.
So, what are electrical safety devices? These devices are specifically designed to mitigate the risks associated with electricity. They work by detecting abnormalities, interrupting the flow of electricity, or providing grounding mechanisms to ensure user safety.
In industrial settings, electrical safety devices play a vital role in preventing accidents and maintaining a secure working environment. They are used to safeguarding equipment, prevent electrical fires, and protect workers from electric shock hazards.
In residential settings, electrical safety devices are essential for creating a safe home environment. They help prevent electrical fires, minimize the risk of electrical accidents, and protect individuals from potential electrocution.
Common electrical safety devices include circuit breakers, ground fault circuit interrupters (GFCIs), surge protectors, arc fault circuit interrupters (AFCIs), and isolating transformers. Each device serves a specific purpose in protecting against different types of electrical hazards.
By understanding electrical safety devices and implementing them appropriately, industries and homes can ensure the highest level of electrical safety for their workers and inhabitants, minimizing the risk of accidents and injuries.
The Importance of Electrical Safety
Working safely with electricity is crucial to prevent accidents, injuries, and potentially disastrous consequences. It is vital for individuals to understand the various risks associated with electrical systems in order to mitigate these dangers effectively.
Electrical Safety Risks: Electricity poses several risks if not handled properly. Some common safety risks include electrical fires, electrocution, and damage to electrical devices and appliances. It is essential to take appropriate measures to minimize these risks and ensure a safe working environment.
Electrical Fires: Improper electrical installations, equipment malfunction, and overloaded circuits can lead to electrical fires. These fires can spread quickly and cause significant damage to property and even endanger lives. Understanding the causes and implementing preventative measures are essential to reduce the risk of electrical fires.
Electrical Wire Colors: Familiarity with electrical wire colors is crucial for safety. Electrical wires are color-coded to indicate their purpose and voltage. Understanding these color codes helps in proper installation, troubleshooting, and maintenance of electrical systems, reducing the risk of accidents and injuries.
Basics of Electrical Safety: Implementing basic electrical safety practices is essential for everyone, especially those working with electricity regularly. These include wearing proper personal protective equipment (PPE), ensuring proper grounding of electrical systems, using circuit breakers and fuses, and avoiding contact with live wires. Adhering to these fundamental safety measures greatly reduces the risks associated with electrical work.
The Role of Electrical PPE in Safety
Personal protective equipment (PPE) is essential for safeguarding workers against potential electrical hazards. When working with electricity, there is always a risk of arc flash and shock hazards. These PPE requirements are put in place to minimize the severity of injuries and protect individuals from life-threatening incidents.
One of the most critical aspects of electrical PPE is protecting against arc flash incidents. An arc flash can occur when there is an electrical fault or short circuit, resulting in a release of intense heat and light. Without proper protection, workers can suffer severe burns and other injuries. To mitigate these risks, electrical PPE includes flame-resistant clothing, face shields, and arc-rated gloves.
In addition to arc flash protection, electrical PPE also addresses the risk of shock hazards. Electrical shocks can cause serious injuries, including cardiac arrest and burns. To prevent such incidents, workers must wear insulated gloves, safety boots, and other appropriate gear when working with live electrical systems.
Moreover, it is crucial to ensure that workers have the necessary training and knowledge to use electrical PPE effectively. They should understand the different PPE requirements for specific tasks and be aware of the limitations and guidelines for their use. Regular inspections and maintenance of PPE are also vital to ensure their reliability and effectiveness.
FAQ
What are electrical safety devices?
Electrical safety devices are equipment or devices designed to prevent electrical hazards and protect people, property, and equipment from potential dangers associated with electricity. These devices are used in industries and homes to ensure the safe use and management of electrical systems.
Why are electrical safety devices important in industry?
Electrical safety devices are crucial in industry because they help prevent electrical accidents, fires, and injuries. They ensure the safe operation of electrical systems and protect workers, equipment, and property from the potential hazards of electricity.
What are some common electrical safety devices used in industry?
Some common electrical safety devices used in industry include circuit breakers, ground fault circuit interrupters (GFCIs), surge protectors, arc fault circuit interrupters (AFCIs), and residual current devices (RCDs). These devices help detect and prevent electrical faults, overloads, and ground faults, improving overall safety.
How do electrical safety devices work?
Electrical safety devices work by monitoring and controlling the flow of electrical current. For example, circuit breakers automatically trip and interrupt the circuit when they detect an overcurrent or overload. GFCIs detect ground faults and quickly shut off power to prevent electric shock. Surge protectors divert excess voltage to protect connected devices. AFCIs detect dangerous arcing faults and interrupt the circuit. RCDs monitor the balance of current flow and trip when they sense a ground fault.
What is the purpose of personal protective equipment (PPE) in electrical safety?
Personal protective equipment (PPE) plays a crucial role in ensuring electrical safety. It is designed to protect workers from electrical hazards, such as electric shock and arc flash. PPE includes specialized clothing, gloves, goggles, helmets, and footwear that provide insulation and resist electrical current to minimize the risk of injury.
What should be considered when using electrical PPE?
When using electrical PPE, it is important to ensure that it is the appropriate type and rating for the specific electrical hazard. PPE should be regularly inspected for damage, and workers should receive proper training on its correct usage. Additionally, it should fit properly and be comfortable to wear to ensure maximum effectiveness in protecting against electrical hazards.