1082024 Phoenix Contact Electrical Safety Devices
Part#:1082024
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Safety relay for emergency stop, safety doors, and light grids up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1082024 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (operation) -40 °C ... 60 °C (observe derating)
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Rated control circuit supply voltage US 24 V DC -20 % / +25 % (provide external protection)
- Filter time max. 3 ms (Test pulse width of low test pulses)
- Current consumption 2.5 mA (Typically with US at S34)
- Protective circuit/component 33 V suppressor diode
- Switching voltage min. 5 V AC/DC
- Switching capacity according to IEC 60947-5-1 5 A (24 V (DC13))
- Typical response time at US < 100 ms (automatic start)
- Recovery time 500 ms (following demand of the safety function)
- Assembly instructions See derating curve
- Housing material PBT
- Connection method Screw connection
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Safety Integrity Level (SIL) 3
- Width 22.5 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Power consumption at US typ. 1.8 W
- Number of inputs 2
- Concurrence ∞
- Output description PNP
- Output fuse 6 A gL/gG
- Voltage approx. 23 V DC (Us - 1 V)
- Typical release time at US < 20 ms (on demand via the sensor circuit)
- Nominal operating mode 100% operating factor
- Mounting position vertical or horizontal
- Status display 2 x green LEDs
- Conductor cross-section AWG 24 ... 12
- Screw thread M3
- Performance level (PL) e (5 A DC13; 8760 switching cycles/year or 5 A AC15; 2190 switching cycles/year)
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Maximum altitude ≤ 2000 m (Above sea level)
- Inrush current min. 10 mA AC/DC
- Input voltage range "1" signal 19.2 V DC ... 30 V DC
- Max. permissible overall conductor resistance 150 Ω
- Contact material AgSnO2
- Contact type 3 enabling current paths
- Switching frequency 0.5 Hz (ohmic)
- Switching capacity min. 50 mW
- Typical pickup time at US < 100 ms (when controlled via A1)
- Mounting type DIN rail mounting
- Min. degree of protection of inst. location IP54
- Housing color yellow
- pluggable Yes
- Stripping length 7 mm
- Category 4
- Rated insulation voltage 250 V AC
- Rated surge voltage/insulation Basic insulation 4 kV between all current paths
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 10.0.1 27371819
- Depth 114.5 mm
- Protective circuit Serial protection against polarity reversal
- Description of the input non-safety-related
- Input current range "0" signal 0 mA ... 2 mA (S10, S12)
- Output name Enabling current paths
- Limiting continuous current 6 A
- Mechanical service life 10x 106 cycles
- Current max. 100 mA
- Restart time < 1 s (Boot time)
- Net weight 185.26 g
- Degree of protection IP20
- Operating voltage display 1 x green LED
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Stop category 0
- Safety Integrity Level Claim Limit (SIL CL) 3
- Degree of pollution 2
- Conformance CE-compliant
- China RoHS Environmentally Friendly Use Period = 50 years
- Height 112.4 mm
- Designation Air clearances and creepage distances between the power circuits
- Rated control supply current IS typ. 75 mA
- Input name Start circuit
- Input voltage range "0" signal 0 V ... 5 V (S10, S12)
- Number of outputs 1
- Sq. Total current 72 A2 (observe derating)
- Maximum inrush current 1 A (Δt = 5 ms at Us)
- Short-circuit protection Yes
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- REACh SVHC Lead 7439-92-1
- ECLASS 9.0 27371819
- Standards/regulations EN 60947-5-1
- Overvoltage category II
- Shock 15g for Δt = 11 ms (continuous shock: 10g for Δt = 16 ms)
- ECLASS 11.0 27371819
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨