LC1D09F7 Schneider Electric Automation components
Part#:LC1D09F7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 5
May 18, 2024
About the product: Schneider Electric - LC1D09F7
About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D09F7 Schneider Electric price in the box on the right side or send a quick quote.
LC1D09F7 Product Details
- Product Certifications UL GOST GL CCC BV LROS (Lloyds register of shipping) CSA DNV RINA
- [Icw] Rated Short-Time Withstand Current 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
- Motor Power HP (UL / CSA) 1 hp 230/240 V at AC 50/60 Hz for 1 phase 2 hp 200/208 V at AC 50/60 Hz for 3 phase 2 hp 230/240 V at AC 50/60 Hz for 3 phase 5 hp 460/480 V at AC 50/60 Hz for 3 phase 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase 0.33 hp 115 V at A
- Motor Power Kw 2.2 kW 220...230 V AC 50/60 Hz AC-3) 4 kW 380...400 V AC 50/60 Hz AC-3) 4 kW 415...440 V AC 50/60 Hz AC-3) 5.5 kW 500 V AC 50/60 Hz AC-3) 5.5 kW 660...690 V AC 50/60 Hz AC-3) 2.2 kW 400 V AC 50/60 Hz AC-4)
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Control Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Tightening Torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lb
- Utilisation Category AC-1 AC-3 AC-4
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit
- Connections - Terminals Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible
- Irms Rated Making Capacity 250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Inrush Power In VA 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Mounting Support Plate Rail
- Contactor Application Resistive load Motor control
- Power Dissipation Per Pole 1.56 W AC-1 0.2 W AC-3
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Operating Time 12...22 ms closing 4...19 ms opening
- [Ie] Rated Operational Current 9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- [Ith] Conventional Free Air Thermal Current 25 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit
- Hold-In Power Consumption In VA 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
- Electrical Durability 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Front Cover With
- Signalling Circuit Frequency 25...400 Hz
- Minimum Switching Voltage 17 V signalling circuit
- Heat Dissipation 2…3 W 50/60 Hz
- Mechanical Durability 15 Mcycles
- Coil Technology Without built-in suppressor module
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Average Impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit
- Rated Breaking Capacity 250 A 440 V power circuit IEC 60947
- Overvoltage Category III
- Auxiliary Contact Composition 1 NO + 1 NC
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- [Uc] Control Circuit Voltage 110 V AC 50/60 Hz
- Control Circuit Type AC 50/60 Hz
- Device Short Name LC1D
- Product Name TeSys D
- Power Pole Contact Composition 3 NO
- Poles Description 3P
- Product Or Component Type Contactor
- Range TeSys
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Related documents LC1D09F7 Specs
This item can ship within 5 days!
1-year warranty
$33.16
LC1D09F7
Stock:
5
Select Qty:
$33.16
$33.16 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨