LC1D115P7 Schneider Electric Automation components
Part#:LC1D115P7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 8
May 18, 2024
About the product: Schneider Electric - LC1D115P7
About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D115P7 Schneider Electric price in the box on the right side or send a quick quote.
LC1D115P7 Product Details
- Product Certifications LROS (Lloyds register of shipping) RINA DNV GOST BV GL CCC CSA UL UKCA
- Motor Power Kw 30 kW 220...230 V AC 50/60 Hz AC-3) 55 kW 380...400 V AC 50/60 Hz AC-3) 59 kW 415...440 V AC 50/60 Hz AC-3) 75 kW 500 V AC 50/60 Hz AC-3) 80 kW 660...690 V AC 50/60 Hz AC-3) 65 kW 1000 V AC 50/60 Hz AC-3) 18.5 kW 400 V AC 50/
- [Icw] Rated Short-Time Withstand Current 250 A 104 °F (40 °C) - 10 min power circuit 550 A 104 °F (40 °C) - 1 min power circuit 950 A 104 °F (40 °C) - 10 s power circuit 1100 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling ci
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Motor Power HP (UL / CSA) 30 hp 200/208 V at AC 50/60 Hz for 3 phase 40 hp 230/240 V at AC 50/60 Hz for 3 phase 75 hp 460/480 V at AC 50/60 Hz for 3 phase 100 hp 575/600 V at AC 50/60 Hz for 3 phase
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)fl
- Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
- Irms Rated Making Capacity 1260 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
- Utilisation Category AC-1 AC-4 AC-3
- Associated Fuse Rating 250 A gG <= 690 V type 1 power circuit 200 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit
- Control Circuit Voltage Limits 0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz 1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
- Hold-In Power Consumption In VA 2…18 VA 60 Hz 0.3 68 °F (20 °C)) 2…18 VA 50 Hz 0.3 68 °F (20 °C))
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Inrush Power In VA 280…350 VA 60 Hz 0.8 68 °F (20 °C)) 280…350 VA 50 Hz 0.8 68 °F (20 °C))
- [Ie] Rated Operational Current 200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 115 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- Power Dissipation Per Pole 24 W AC-1 7.9 W AC-3
- Operating Time 6...20 ms opening 20...50 ms closing
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Electrical Durability 0.8 Mcycles 200 A AC-1 <= 440 V 0.95 Mcycles 115 A AC-3 <= 440 V
- Contactor Application Motor control Resistive load
- Mounting Support Rail Plate
- [Ue] Rated Operational Voltage Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Minimum Switching Current 5 mA signalling circuit
- Heat Dissipation 3…8 W 50/60 Hz
- Maximum Operating Rate 2400 cyc/h 60 °C
- Front Cover With
- Average Impedance 0.6 mOhm - Ith 200 A 50 Hz power circuit
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Mechanical Durability 8 Mcycles
- Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
- [Ith] Conventional Free Air Thermal Current 200 A 140 °F (60 °C) power circuit
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
- Auxiliary Contact Composition 1 NO + 1 NC
- [Uc] Control Circuit Voltage 230 V AC 50/60 Hz
- Control Circuit Type AC 50/60 Hz
- Poles Description 3P
- Device Short Name LC1D
- Power Pole Contact Composition 3 NO
- Product Or Component Type Contactor
- Range TeSys
- Product Name TeSys D
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Related documents LC1D115P7 Specs
This item can ship within 3 days!
1-year warranty
$303.68
LC1D115P7
Stock:
8
Select Qty:
$303.68
$303.68 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨