LC1D09P7 Schneider Electric Automation components

Schneider Electric LC1D09P7 Schneider Electric - LC1D09P7
Schneider Electric

Part#:LC1D09P7

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 5

May 20, 2024

About the product: Schneider Electric - LC1D09P7

About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D09P7 Schneider Electric price in the box on the right side or send a quick quote.

LC1D09P7 Product Details

  • Product Certifications
    GOST BV LROS (Lloyds register of shipping) DNV CSA RINA CCC UL GL
  • [Icw] Rated Short-Time Withstand Current
    105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power Kw
    2.2 kW 220...230 V AC 50/60 Hz AC-3) 4 kW 380...400 V AC 50/60 Hz AC-3) 4 kW 415...440 V AC 50/60 Hz AC-3) 5.5 kW 500 V AC 50/60 Hz AC-3) 5.5 kW 660...690 V AC 50/60 Hz AC-3) 2.2 kW 400 V AC 50/60 Hz AC-4)
  • Motor Power HP (UL / CSA)
    1 hp 230/240 V at AC 50/60 Hz for 1 phase 2 hp 200/208 V at AC 50/60 Hz for 3 phase 2 hp 230/240 V at AC 50/60 Hz for 3 phase 5 hp 460/480 V at AC 50/60 Hz for 3 phase 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase 0.33 hp 115 V at A
  • [Ui] Rated Insulation Voltage
    Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Tightening Torque
    Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lb
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Connections - Terminals
    Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit
  • Irms Rated Making Capacity
    250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation Category
    AC-4 AC-1 AC-3
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Hold-In Power Consumption In VA
    7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
  • Operating Time
    12...22 ms closing 4...19 ms opening
  • Electrical Durability
    0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V
  • Power Dissipation Per Pole
    1.56 W AC-1 0.2 W AC-3
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • [Ith] Conventional Free Air Thermal Current
    25 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit
  • [Ie] Rated Operational Current
    9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Mounting Support
    Rail Plate
  • Inrush Power In VA
    70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Contactor Application
    Resistive load Motor control
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Heat Dissipation
    2…3 W 50/60 Hz
  • Coil Technology
    Without built-in suppressor module
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability
    15 Mcycles
  • Front Cover
    With
  • Average Impedance
    2.5 mOhm - Ith 25 A 50 Hz power circuit
  • Rated Breaking Capacity
    250 A 440 V power circuit IEC 60947
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    230 V AC 50/60 Hz
  • Control Circuit Type
    AC 50/60 Hz
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Product Or Component Type
    Contactor
  • Device Short Name
    LC1D
  • Product Name
    TeSys D
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


This item can ship within 3 days!

1-year warranty

$83.73

LC1D09P7

Stock:

5

Select Qty:

$83.73

$83.73 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo