Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

LC1D096BL Schneider Electric Automation components

Schneider Electric LC1D096BL Schneider Electric - LC1D096BL
Schneider Electric

Part#:LC1D096BL

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

About the product: Schneider Electric - LC1D096BL

About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D096BL Schneider Electric price in the box on the right side or send a quick quote.

LC1D096BL Product Details

  • Product Certifications
    BV GL UL GOST RINA CCC CSA DNV LROS (Lloyds register of shipping)
  • [Ui] Rated Insulation Voltage
    Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • [Icw] Rated Short-Time Withstand Current
    105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
  • Motor Power HP (UL / CSA)
    1 hp 230/240 V at AC 50/60 Hz for 1 phase 2 hp 200/208 V at AC 50/60 Hz for 3 phase 2 hp 230/240 V at AC 50/60 Hz for 3 phase 5 hp 460/480 V at AC 50/60 Hz for 3 phase 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase 0.33 hp 115 V at A
  • Motor Power Kw
    2.2 kW 220...230 V AC 50/60 Hz AC-3) 4 kW 380...400 V AC 50/60 Hz AC-3) 4 kW 415...440 V AC 50/60 Hz AC-3) 5.5 kW 500 V AC 50/60 Hz AC-3) 5.5 kW 660...690 V AC 50/60 Hz AC-3) 2.2 kW 400 V AC 50/60 Hz AC-4)
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 8 mm M3.5 Power circuit
  • Control Circuit Voltage Limits
    0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
  • Irms Rated Making Capacity
    250 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation Category
    AC-1 AC-3 AC-4
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • [Ie] Rated Operational Current
    9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Contactor Application
    Resistive load Motor control
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ith] Conventional Free Air Thermal Current
    25 A 140 °F (60 °C) power circuit 10 A 140 °F (60 °C) signalling circuit
  • Power Dissipation Per Pole
    1.56 W AC-1 0.2 W AC-3
  • Electrical Durability
    0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V
  • Mounting Support
    Rail Plate
  • Operating Time
    65.45...88.55 ms closing 20...30 ms opening
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Minimum Switching Current
    5 mA signalling circuit
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Inrush Power In W
    2.4 W 68 °F (20 °C))
  • Hold-In Power Consumption In W
    2.4 W 68 °F (20 °C)
  • Time Constant
    40 ms
  • Mechanical Durability
    30 Mcycles
  • Coil Technology
    Built-in bidirectional peak limiting diode suppressor
  • Front Cover
    With
  • Rated Breaking Capacity
    250 A 440 V power circuit IEC 60947
  • Average Impedance
    2.5 mOhm - Ith 25 A 50 Hz power circuit
  • Overvoltage Category
    III
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Control Circuit Type
    DC low consumption
  • [Uc] Control Circuit Voltage
    24 V DC
  • Device Short Name
    LC1D
  • Product Or Component Type
    Contactor
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Range
    TeSys
  • Product Name
    TeSys D

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

LC1D096BL

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo