Phoenix Contact 3211909 Disconnect terminal block, nom. voltage: 500 V, nominal current: 28 A, connection method: Push-in connection, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, length: 102.9 mm, width: 6.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3211909

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 32

Nov 2, 2024

Disconnect terminal block, nom. voltage: 500 V, nominal current: 28 A, connection method: Push-in connection, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, length: 102.9 mm, width: 6.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3211909 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of levels
    2
  • Number of connections
    4
  • Nominal cross section
    4 mm²
  • Flammability rating according to UL 94
    V0
  • Degree of pollution
    3
  • Maximum power dissipation for nominal condition
    1.02 W (the value is multiplied when connecting multiple levels)
  • Open side panel
    Yes
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of tight fit on support
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Conductor cross section short circuit testing
    4 mm²
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Rated surge voltage
    6 kV
  • Overvoltage category
    III
  • Maximum load current
    20 A
  • Nominal voltage UN
    500 V (Current and voltage are determined by the plug used.)
  • Back of the hand protection
    guaranteed
  • Finger protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Tight fit on carrier
    NS 35
  • Setpoint
    1 N
  • Short circuit stability result
    Test passed
  • Result of aging test
    Test passed
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Test duration per axis
    5 h
  • Shock duration
    30 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    102.9 mm
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Internal cylindrical gage
    A4
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141121
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000902
  • UNSPSC 6.01
    30211811
  • UNSPSC 13.2
    39121410
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    54.9 mm
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Connection cross sections directly pluggable
    0.5 mm² 6 mm² 20 10
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141126
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 21.0
    39121410
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • ASD level
    0.964 (m/s2)2/Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141126
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141126
  • ETIM 7.0
    EC000902
  • UNSPSC 18.0
    39121410
  • Note
    Current and voltage are determined by the plug used.
  • Potentials
    2
  • Color
    gray
  • Insulating material
    PA
  • Area of application
    Plant engineering
  • Insulating material group
    I
  • Nominal current IN
    20 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test turns
    135
  • Tensile test result
    Test passed
  • Result of voltage-drop test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.48 kA
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Oscillation, broadband noise test result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Shock test result
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    47.4 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section AWG max.
    10
  • Max. AWG conductor cross section, flexible
    12
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141121
  • ETIM 2.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 19.0
    39121410
  • Acceleration
    5g
  • Shock form
    Half-sine
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    6.2 mm
  • Connection
    2nd level
  • Conductor cross section solid max.
    6 mm²
  • Min. AWG conductor cross section, flexible
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 20.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$4.68

Stock:

32

Select Qty:

$4.68

$4.68 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo