3211825 Phoenix Contact Terminal Blocks

Phoenix Contact 3211825 Double-level terminal block, With equipotential bonder, connection method: Push-in connection, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3211825

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Double-level terminal block, With equipotential bonder, connection method: Push-in connection, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3211825 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Stripping length
    10 mm ... 12 mm
  • ETIM 3.0
    EC000897
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • ECLASS 11.0
    27141120
  • ECLASS 10.0.1
    27141120
  • ECLASS 9.0
    27141120
  • Result of power-frequency withstand voltage test
    Test passed
  • Conductor cross section tensile test
    6 mm²
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Checking the mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Connection in acc. with standard
    CSA
  • Result of temperature-rise test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Oscillation, broadband noise test result
    Test passed
  • Shock duration
    18 ms
  • Height NS 35/7,5
    47.5 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • UNSPSC 11
    39121410
  • Back of the hand protection
    guaranteed
  • ECLASS 5.1
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Conductor cross section solid max.
    6 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • UNSPSC 13.2
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    10
  • ECLASS 7.0
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • ETIM 6.0
    EC000897
  • UNSPSC 12.01
    39121410
  • UNSPSC 21.0
    39121410
  • UNSPSC 18.0
    39121410
  • Insulating material group
    I
  • Nominal current IN
    30 A (with 4 mm² conductor cross section)
  • Color
    gray
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of surge voltage test
    Test passed
  • Tensile test result
    Test passed
  • Result of tight fit on support
    Test passed
  • Setpoint
    1 N
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test duration per axis
    5 h
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Number of levels
    2
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    1.02 W (the value is multiplied when connecting multiple levels)
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Nominal voltage UN
    500 V
  • Finger protection
    guaranteed
  • Bending test rotation speed
    10 rpm
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Result of voltage-drop test
    Test passed
  • Short-time current
    0.72 kA
  • Result of aging test
    Test passed
  • Acceleration
    30g
  • Shock test result
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Insulating material
    PA
  • Area of application
    Railway industry
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Width
    6.2 mm
  • Number of connections
    4
  • Rated surge voltage
    6 kV
  • Maximum load current
    32 A (for a 6 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors)
  • Open side panel
    Yes
  • Surge voltage test setpoint
    7.3 kV
  • Result of flexion and pull-out test
    Test passed
  • Bending test turns
    135
  • Tractive force setpoint
    80 N
  • Conductor cross section short circuit testing
    6 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Nominal cross section
    4 mm²
  • Degree of pollution
    3
  • Overvoltage category
    III
  • Short circuit stability result
    Test passed
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Relative insulation material temperature index (Elec.; UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    55 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Tight fit on carrier
    NS 35
  • Result of thermal test
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Length
    83.5 mm
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Conductor cross section AWG min.
    24
  • Internal cylindrical gage
    A4
  • ECLASS 4.1
    27141100
  • ECLASS 4.0
    27141100
  • Requirements, voltage drop
    ≤ 3.2 mV

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo